Two Core 60 a 10mm 600/1000V XLPE Insulated Al Service Cable Complete with 2X0.5 mm2 Pilot Cores Concentric Cable

Two Core 60 a 10mm 600/1000V XLPE Insulated Al Service Cable Complete with 2X0.5 mm2 Pilot Cores Concentric Cable

Two Core 60 a 10mm 600/1000V XLPE Insulated Al Service Cable Complete with 2X0.5 mm2 Pilot Cores Concentric Cable

Service Cable

Construction, Overhead

Low and Medium Voltage Cable

AC Cable

XLPE

PVC

Round Wire

Copper or Aluminum

CCC, CE

Vlv72

Yifang

Black

IEC 60502

Yifang

Drum, Reel or According to Customers' Request

drum

China

8544492100

Product Description

Two core 60 A 10mm 600/1000V XLPE Insulated Al Service Cable Complete with 2×0.5 mm2 PILOT Cores Concentric Cable

 Applications

The concentric cable is used as electric service entrance from the power distribution network until meter panel ,and as feeder cable from the meters panel until the panel or general distribution panel,just as it is specified in the National electric code,

This type of conductor can be used in dry and wet place,directly buried or outdoor;

It’s maximum temperature of operation is 70ºC( PVC or PE insulation) or 90ºC (XLPE insulation) and it’s voltage of service for all the applications is 600/1000V.

 

Specification

1. Conductor : Copper or Aluminum or 8000 series Aluminum Alloy

2.  Insulation: PVC or PE or XLPE

3.  Concentric neutral: Copper or Aluminum or 8000 series Aluminum Alloy

4.   Sheath: PVC or PE or XLPE

ITEM

SPECIFICATION (PARTICULARS

UNIT

  Data

1

Insulation Voltage

V

600/1000

2

Conductor size

mm²

16

3

Phase Conductor material

N/A

Hard drawn 7strands Aluminium conductor

-Single Core

4

Insulation Material

N/A

XLPE

5

Earth wire material type

N/A

Bare Aluminium conductor

6

Rip Chord

N/A

Nylon or as your requirement

7

Reference Standards

N/A

SANS 1507, NRS 063, IEC 60502/228 ESI 09-7

8

Phase conductor Insulation thickness

mm

1.0

 

Construction (Phase conductor)

 

 

9

Structure

mm

Single core

10

Insulation Thickness

mm

1.0

11

Reference Insulation O.D

mm

7.1

 

Construction (Earth Wire)

 

 

12

Structure

Numbers

14

13

Wire structure

N/A

14/1.21

 

Construction (Pilot/Communication Wires)

 

 

14

Structure

mm²

2X0.5

15

Reference Insulation O.D

mm

Min.1.13

16

Conductor material

N/A

Hard drawn Aluminium conductor

17

Insulation Material

N/A

LPDE/XLPE

18

Number of conductors

Numbers

2

 

Construction (Sheath)

 

 

19

Nominal Thickness

mm

1.0

20

Reference Insulation O.D

mm

11.5

21

Sheath Material

N/A

 Black LDPE

 

Insulation material colours

 

 

22

Phase conductor

N/A

Red

23

Pilot wires (04)

N/A

Red, Blue

24

Sheath

N/A

Black

 

Performance (Electrical Characteristics)

 

 

25

Phase Conductor – Maximum resistance at 

 

≤1.91

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.