Supply Best Price of Service Drop Cable AAC ACSR /PVC Cable ABC Cable

Supply Best Price of Service Drop Cable AAC ACSR /PVC Cable ABC Cable

Supply Best Price of Service Drop Cable AAC ACSR /PVC Cable ABC Cable

ABC

Jinyuan

ISO9001, CE, CCC, RoHS

Oveahead

Round Wire

XLPE

No

Aluminum

Overhead, Underground

Stranded

Insulated

LV. Mv. Hv

as Per Your Customers ' Request

PVC/PE/XLPE

Within 15-20 Days

Jinyuan

All Wooden, Steel Wooden or Steel Package

China

8544492100

Product Description

supply best price of service drop cable AAC ACSR /PVC cable ABC cable
We produce the ABC Electric Cable used for overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM, BS, NF C 33-209 standard.

LV ABC cable(Aerial Bundle cable) with AAAC conductor

Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, Duplex, Triplex, Quadruplex.

Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.

Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:

Duplex Service Drop

Triplex Service Drop

Quadruplex Service Drop

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.

 Detaild Introduction of Service Drop Cable
1  Duplex Service Drop
Applications: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction: Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

2 Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.

Construction: Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

 3 Quadruplex Service Drop
Applications: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction: Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.
 
Product Description
1.Application:
Pvc insulated abc cable as a new-type aerial cable is used for transmitting electric power overhead, extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.

2.Specification:
Concentric strand aluminum wires as phase conductor; AAAC(all aluminum alloy conductors) or ACSR(aluminum conductor steel reinforced) as messenger (Neutral) core; Phase conductor is insulated by XLPE or HDPE or PVC.

3.Standards:
IEC60502, NF C33-209, GB 12527-90
Rated voltage: 0.6/1kV
Relative manufacturing standards: IEC61089, ASTM B231, ASTM B232, BS215, DIN48201, DIN48204.

4.It meets or exceeds the following specifications:
1. Aluminum Wire, 1350-H19 for Electrical Purposes.
2. Aluminum Conductors, Concentric-Lay-Stranded.
3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. Concentric-Lay-Stranded 6201-T81 Conductors.
5. Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
It meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
5.Construction & descriptions:

specifications      
 (mm2)                    
specifications      
 (mm2) 
specifications      
 (mm2)
 
specifications      
 (mm2)  
1×10 1×120+120 2×50+50 3×10+10
1×16 1×150+150 2×70+70 3×16+16
1×25 1×185+185 2×95+95 3×25+25
1×35 1×240+240 2×120+120 3×35+35
1×50 1×16+16(Bare) 2×150+150 3×50+50
1×70 1×25+25(Bare) 2×185+185 3×70+70
1×95 1×35+35(Bare) 2×240+240 3×95+95
1×120 1×50+50(Bare) 2×10+10(Bare) 3×120+120
1×150 1×70+70(Bare) 2×16+16(Bare) 3×150+150
1×185 1×95+95(Bare) 2×25+25(Bare) 3×185+185
1×240 1×120+120(Bare) 2×35+35(Bare) 3×240+240
1×10+10 1×150+150(Bare) 2×50+50(Bare) 3×16+16(Bare)
1×16+16 1×185+185(Bare) 2×70+70(Bare) 3×25+25(Bare)
1×25+25 1×240+240(Bare) 2×95+95(Bare) 3×35+35(Bare)
1×35+35 2×10+10 2×120+120(Bare) 3×50+50(Bare)
1×50+50 2×16+16 2×150+150(Bare) 3×70+70(Bare)
1×70+70 2×25+25 2×185+185(Bare)  
1×95+95 2×35+35 2×240+240(Bare)  

FAQ:
(1).When can I get the price? 
    We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please
call us or tell us in your e-mail so that we will regard your inquiry priority.
 
(2).How can I get a sample to check your quality?
    After price confirmation, you can require for samples to check our quality. Sample is free, but the freight
charge should be paid.
 
(3).How long can I expect to get the sample?
    After you pay the freight charge and send us confirmed files,  the samples will be ready for delivery in 3-7
days. The samples will be sent to you via express and arrive in 3-5 days. You can use your own express account orprepay us if you do not have an account.
 
(4).What about the lead time for mass production? 
    Honestly, it depends on the order quantity and the season you place the order.The best record we keep is
delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months
before the date you would like to get the products at your country.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.