Construction Companies 0.6 / 1 Kv ACSR Conductor XLPE Triplex Service Drop ABC Overhead Cable Cockle with High Quality

Construction Companies 0.6 / 1 Kv ACSR Conductor XLPE Triplex Service Drop ABC Overhead Cable Cockle with High Quality

Construction Companies 0.6 / 1 Kv ACSR Conductor XLPE Triplex Service Drop ABC Overhead Cable Cockle with High Quality

Jinyuan

ISO9001, CE, CCC, RoHS

Oveahead

Round Wire

XLPE

No

Aluminum

Overhead, Underground

Stranded

Insulated

LV. Mv. Hv

as Per Your Customers ' Request

PVC/PE/XLPE

Jinyuan

All Wooden, Steel Wooden or Steel Package

China

8544492100

Product Description

Construction companies 0.6 / 1 kv ACSR conductor xlpe triplex service drop abc overhead cable Cockle with high quality
1.APPLICATION   xlpe abc overhead cable Cockle
To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene Insulation or 90°C maximum for crosslinked insulation.

2.CONSTRUSTION    xlpe abc overhead cable Cockle
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR or 6201 alloy neutral messenger.

 
3.SPECIFICATION    xlpe abc overhead cable Cockle
B-230 Aluminum Wire 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.
There is a lot of debate still going on as to whether copper is better for electrical purposes or aluminum. If price was not a critical factor, most would suggest going in for silver as it is said to be the best conductor of electricity but has a low strength. However, when it comes to electrical wiring, price is a factor, as is efficiency.
 

Code* Word Phase Conductor Bare Neutral Messenger Weight
per 1000 ft. (lbs.)
Allowable
Ampacities+
Size
(AWG)
Strand-
ing
Insul.
Thick.
(mils)
Size
(AWG)
Strand-ing Rated
Strength
(lbs.)
XLP POLY XLP POLY
ACSR REDUCED NEUTRAL-MESSENGER
Scallop 4 1 45 6 6/1 1190   142 115 90
Strombus 4 7 45 6 6/1 1190 151 151 115 90
Cockle 2 7 45 4 6/1 1860 228 228 150 120
Janthina 1/0 7 60 2 6/1 2853 366 366 205 160
Ranella 1/0 9 60 2 6/1 2853 360 360 205 160
Cavolinia 2/0 7 60 1 6/1 3550 453 453 235 185
Clio 2/0 11 60 1 6/1 3550 444 444 235 185
Aega 3/0 17 60 1/0 6/1 4380 549 549 275 215
Cerapus 4/0 18 60 2/0 6/1 5310 681 681 315 245

  * Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).
 + Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun.

specifications      
 (mm2)                    
specifications      
 (mm2) 
specifications      
 (mm2)
 
specifications      
 (mm2)  
1×10 1×120+120 2×50+50 3×10+10
1×16 1×150+150 2×70+70 3×16+16
1×25 1×185+185 2×95+95 3×25+25
1×35 1×240+240 2×120+120 3×35+35
1×50 1×16+16(Bare) 2×150+150 3×50+50
1×70 1×25+25(Bare) 2×185+185 3×70+70
1×95 1×35+35(Bare) 2×240+240 3×95+95
1×120 1×50+50(Bare) 2×10+10(Bare) 3×120+120
1×150 1×70+70(Bare) 2×16+16(Bare) 3×150+150
1×185 1×95+95(Bare) 2×25+25(Bare) 3×185+185
1×240 1×120+120(Bare) 2×35+35(Bare) 3×240+240
1×10+10 1×150+150(Bare) 2×50+50(Bare) 3×16+16(Bare)
1×16+16 1×185+185(Bare) 2×70+70(Bare) 3×25+25(Bare)
1×25+25 1×240+240(Bare) 2×95+95(Bare) 3×35+35(Bare)
1×35+35 2×10+10 2×120+120(Bare) 3×50+50(Bare)
1×50+50 2×16+16 2×150+150(Bare) 3×70+70(Bare)
1×70+70 2×25+25 2×185+185(Bare)  
1×95+95 2×35+35 2×240+240(Bare)  

Duplex Service Drop

Code
word
AWG or kcmil Bare Neutral Messenger Phase conductor Weight
Kg/km
Allowcable
Ampacities(A)
ACSR Rated
Strength
Lbs.
AAC Insul
Thick.mm
XLPE PE
Number Dia.
mm
Number Dia.mm Number Dia.mm
Setter
Shepherd
Eskimo
Terrier
Chow
Bull
1*6AWG+1*6AWG
1*6AWG+1*6AWG
1*4AWG+1*4AWG
1*4AWG+1*4AWG
1*2AWG+1*2AWG
1*1/0AWG+1*1/0AWG
1
1
1
1
1
1
1.68
1.68
2.12
2.12
2.67
3.37
6
6
6
6
6
6
1.68
1.68
2.12
2.12
2.67
3.37
1190
1190
1860
1860
2850
4380
1
7
1
7
7
19
4.11
1.56
5.19
1.96
2.47
1.89
1.14
1.14
1.14
1.14
1.14
1.52
111
113
171
173
266
427
85
85
115
115
150
205
70
70
90
90
120
160

 

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per 1000 ft.(lbs.) Allo wable Amp acitles
Size (A WG) Stranding Insul Thick(Mils) Size (AWG) Stranding Rated Strength (lbs.) inches XLP POLY XLP POLY
AAC Neutral-messenger
Pateela 6 7 45 6 7 563 14.88 103 103 85 70
Oyster 4 7 45 4 7 881 14.88 154 154 115 90
Clam 2 7 45 2 7 1350 20.58 233 233 150 120
Murex 1/0 7 60 1/0 7 1990 20.58 374 374 205 160
Purpura 1/0 9 60 1/0 7 1990 20.58 368 368 205 160
Nassa 2/0 7 60 2/0 7 2510 25.42 462 462 235 185
Melita 3/0 17 60 3/0 19 3310 29.97 562 562 275 215
Portunus 4/0 18 60 4/0 19 4020 29.97 696 696 315 245
Nannynose 336.4 19 60 336.4 19 6146 38.79 1118 1118 420 325
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) +Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun.

 

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per 1000 ft.(lbs.) Allo wable Amp acitles
Size (A WG) Stranding Insul Thick(Mils) Size (AWG) Stranding Rated Strength (lbs.) inches XLP POLY XLP POLY
AAC Neutral-messenger
Clydessdale 4 1 45 4 7 881 20.58 198 198 100 80
Pinto 4 7 45 4 7 881 20.58 211 211 100 80
Mustang 2 7 45 2 7 1350 25.42 318 318 135 105
Criollo 1/0 9 60 1/0 7 1990 25.42 503 503 180 140
Percheron 2/0 11 60 2/0 7 2510 29.97 619 619 205 160
Hanovarian 3/0 17 60 3/0 19 3310 35.18 764 764 235 185
Oldenburg 4/0 18 60 4/0 19 4020 35.18 945 945 275 210
Lippizaner 336.4 19 80 336.4 19 6146 38.79 1519 1519 370 280
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) +Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.