N2xh, N2xh-J, N2xh-O, 0.6/1kv Solid Copper Halogen-Free and Flame-Resistant Power Cable

N2xh, N2xh-J, N2xh-O, 0.6/1kv Solid Copper Halogen-Free and Flame-Resistant Power Cable

N2xh, N2xh-J, N2xh-O, 0.6/1kv Solid Copper Halogen-Free and Flame-Resistant Power Cable

n2xh

Insulated

Solid and Stranded

Heating, Underground

Copper

PVC

PVC

Round Wire

Installation

ISO9001, CE, CCC

Jytop

AS/NZS 5000.2

PVC, 3V-90 Light Yellow or White

JYTOP

in Rolls or as Drums

4*16mm2

Henan, Zhengzhou

8544492100

Product Description

N2XH,N2XH-J,N2XH-O,0.6/1kV solid copper Halogen-free and Flame-resistant Power Cable

Application:

Halogen-free power cables( N2XH ) with enhanced resistance to fire are used mostly in areas where harm to human life or material must be prevented in case of fire such as industrial and public buildings, hotels, subway systems, hospitals etc. These cables are suitable for dry and wet environments as well as for outer application but are not suitable for direct burial into earth or water.

Cable structure:

  • Solid or stranded Cu core according to DIN VDE 0295 cl. 1 or 2, IEC 60228 cl. 1 or 2
  • Core insulation of halogen free, cross-linked polyethylene compound
  • Cores color coded according to DIN VDE 0293-308, green-yellow earth core in the outer layer, from 3 cores above
  • Cores stranded in layers with optimal lay lenght
  • For N2XCH version, concentric conductor of Cu tape or Cu wire
  • Halogen free sheath of thermoplastic polymer compound, color black

Technical data:

  • Power and control cable according to DIN VDE 0276 part 604
  • Temperature range during installation from -5°C to +50°C; fixed from -40°C to +90°C
  • Nominal voltage Uo/U 0,6/1 kV
  • Test voltage a.c. 4000 V
  • Minimum bending radius for single core approx. 15 x cable diameter, multicore approx. 12 x cable diameter

Tests:

  • Flame-retardant to DIN VDE 0482 part 266-2/HD 405.3/BS 4066 PT3/EN 50266-2/IEC 60332-3
  • Low corrosiveness of combustion gases to DIN VDE 0482 part 267/BS 6425 PT2/EN 50267-2-2/IEC 60754-2
  • Halogen-free to DIN VDE 0482 part 267/BS 6425 PT1/EN 50267-2-1/IEC 60754-1
  • Smoke density to DIN VDE 0482 part 268/HD 606/BS 7622 PT1,PT2/EN 50268-1,-2/IEC 61034-1,-2

Color codes N2XH :

  • 2-core cable: blue/brown
  • 3-core cable: brown/black/grey
  • 4-core cable: blue/brown/black/grey
  • from 7 conductors above, black cores with white numbering

Note:

  • CE = the product is conformed with the EC Low-Voltage Directive 73/23/EEC.
  • rm = round conductor stranded
  • re = round conductor plain
  • Conforms to RoHS.

Dimensions – Number of cores x cross-section

Design Construction of the individual keep the handlers safe The outer diameter thickness of insulation shell thickness Resistance to keep the handlers safe at 20 ° C Weight Cu weight of cable packaging
rated about rated rated max. about
N x mm² n x mm mm mm mm Ω/km kg/km kg/km
1 x 1,5 RE 1 x 1,38 5,4 1,38 0,15 12,10 15,403 43 REZ
1 x 4 RE 1 x 2,25 6,4 2,25 0,20 4,61 5,869 75 REZ
1 x 16 RM 7 x 1,70 9,1 5,00 0,36 1,15 1,464 202 REZ
1 x 25 RM 7 x 2,13 11 6,10 0,48 0,727 0,925 302 REZ
1 x 70 RM 19 x 2,17 15 10,10 0,84 0,268 0,341 745 REZ
1 x 95 RM 19 x 2,52 17 11,90 0,97 0,193 0,246 986 REZ
1 x 185 RM 37 x 2,52 23 16,20 1,72 0,0991 0,126 1888 REZ
1 x 300 RM 61 x 2,50 28 20,60 2,34 0,0601 0,077 2945 REZ
2 x 1,5 RE 1 x 1,38 9 1,38 0,38 12,10 15,403 120 REZ
2 x 2,5 RE 1 x 1,78 10 1,78 0,45 7,41 9,433 154 REZ
2 x 16 RM 7 x 1,70 16 5,00 1,06 1,15 1,464 563 REZ
2 x 25 RM 7 x 2,13 20 6,10 1,52 0,727 0,925 840 REZ
2 x 35 RM 7 x 2,52 22 7,20 1,79 0,524 0,667 1106 REZ
2 x 120 RM 37 x 2,03 36 13,00 4,23 0,153 0,195 3343 REZ
2 x 300 RM 61 x 2,50 55 20,60 9,39 0,0601 0,077 8072 REZ
3 x 1,5 RE 1 x 1,38 9 1,38 0,44 12,10 15,403 135 REZ
3 x 2,5 RE 1 x 1,78 10 1,78 0,51 7,41 9,433 181 REZ
3 x 4 RE 1 x 2,25 11 2,25 0,60 4,61 5,869 242 REZ
3 x 10 RE 1 x 3,56 14 3,57 0,83 1,83 2,330 464 REZ
3 x 16 RM 7 x 1,70 17 5,00 1,22 1,15 1,464 697 REZ
N2XH
3 x 35 RM 7 x 2,52 23 7,20 2,08 0,524 0,667 1393 REZ
3 x 50 RM 19 x 1,83 26 8,30 2,56 0,387 0,493 1847 REZ
3 x 70 RM 19 x 2,17 31 10,10 3,43 0,268 0,341 2666 REZ
3 x 95 RM 19 x 2,52 36 11,90 4,17 0,193 0,246 3535 REZ
3 x 120 RM 37 x 2,03 38 13,00 4,74 0,153 0,195 4322 REZ
3 x 185 RM 37 x 2,52 48 16,20 7,40 0,0991 0,126 6742 REZ
3 x 300 RM 61 x 2,50 59 20,60 10,79 0,0601 0,077 10522 REZ
4 x 1,5 RE 1 x 1,38 10 1,38 0,52 12,10 15,403 163 REZ
4 x 2,5 RE 1 x 1,78 11 1,78 0,60 7,41 9,433 214 REZ
4 x 10 RE 1 x 3,56 16 3,57 1,03 1,83 2,330 586 REZ
4 x 16 RM 7 x 1,70 19 5,00 1,50 1,15 1,464 874 REZ
4 x 35 RM 7 x 2,52 26 7,20 2,57 0,524 0,667 1777 REZ
4 x 50 RM 19 x 1,83 29 8,30 3,15 0,387 0,493 2343 REZ
4 x 120 RM 37 x 2,03 43 13,00 5,98 0,153 0,195 5558 REZ
4 x 185 RM 37 x 2,52 53 16,20 9,35 0,0991 0,126 8657 REZ
4 x 240 RM 61 x 2,24 60 18,80 11,54 0,0754 0,096 11385 REZ
4 x 300 RM 61 x 2,50 65 20,60 13,44 0,0601 0,077 13539 REZ
N2XH
5 x 1,5 RE 1 x 1,38 11 1,38 0,62 12,10 15,403 193 REZ
5 x 4 RE 1 x 2,25 13 2,25 0,85 4,61 5,869 352 REZ
5 x 6 RE 1 x 2,76 15 2,76 0,99 3,08 3,921 475 REZ
5 x 16 RM 7 x 1,70 21 5,00 1,87 1,15 1,464 1081 REZ
5 x 25 RM 7 x 2,13 26 6,10 2,61 0,727 0,925 1631 REZ
5 x 50 RM 19 x 1,83 33 8,30 3,89 0,387 0,493 2915 REZ

REZ = cable in different lengths on reels or spools, and it is possible to cut the desired length