Copper PVC Indualted PVC Sheathed Flexible LSZH Electric Wire Cable
Product Description
H05Z-K, H07Z-K not only meet the HAR certification standards, has a good flame retardant, the use of a wider temperature range, high temperature to +110 ºC, the halogen-free wire fire resistance is good, suitable for drying room, Connect the lights, equipment, switchgear, distribution boxes and so on. They can be used in buildings with densely populated or expensive equipment, but also in public or private transportation. The single conductor can also be installed in casing, marl and cable spoilers. The insulation of the cable adopts halogen-free material, and does not generate corrosive gas when burned. It can protect human life and safety in case of fire, prevent environmental pollution, and prevent the acidic substances generated by combustion from burning on buildings and various equipments harm. This product complies with EEC Regulation 73/23 (Low Voltage Directive) CE. Cable structure: Slightly twisted into stranded bare copper wire conductor, special non-halogen mixture core insulation, flame retardant (IEC603321 rose to IEC60332.3).
H07Z-K PVC insulated rubber sheath low somke zero halogan power cable.
Application:This is a halogen-free single core wire suitable for installation in dry or wet indoor environments, wiring in lighting installations, and wiring in expensive equipment where fire protection must be protected against damage. Can be connected to lights, equipment, switchgear, distribution boxes and so on. Can be used in densely populated or expensive equipment buildings, but also for public or private means of transport, the single core wire can also be installed in the casing, marl and cable trough.
Structure:Single or multiple strands Fine twisted into bundles (tinned) Bare copper wire Special low smoke halogen-free cross-linked polyolefin compound Core insulation (color can be customized according to customer requirements)
Features:Special oil chemical resistance, small bending radius, flame retardant Low smoke when ozone-resistant combustion does not produce toxic substances, to ensure maximum safety of personnel No harmful substances, RoHS
Standard:This product complies with EEC directive 73/23 (Low Voltage Directive) CE Compliant with BS7211, CENELEC HD22.9, with IEC 60332-3-24 TUV approved.
Performance:Operating voltage: 450/750 V Insulation resistance:> 10 GOhm x cm Minimum bend radius: 8x Cable outer diameter.
Operating temperature range:Mobile mounting:-5ºCto+70ºC, fixed mounting: -40ºCto+70ºC.
Flame retardant:in line with the 60332.1 Radiation intensity: the highest 20×106cJ/kg
LSZH insulated Copper Conductor H07Z-K Cable
Electrolytic copper conductor, Class V, according to BS EN 60228:2005 (previously BS6360) and EN 60228. |
Thermostable material insulation with polyolefin base and low smoke and corrosive gas emission, type EI-5, according to UNE 21027-9 and HD 22.9S3:2007. |
450/750 V |
2.500 V in A.C. |
90 ºC |
Colours according to UNE 21027 and HD 22.1S4 Non-flame propagating according to UNE-EN 60332, EN 60332, IEC 60332 Low halogen content according to UNE 21027-9 and HD 22.9S3:2007 Low corrosive gas emission according to UNE 21027-9 and HD 22.9S3:2007 Low opaque smoke emission according to UNE-EN 61034, EN 61034, IEC 61034 |
EN 60332-1 / EN 50266 / EN 50267-1 / EN 50267-2 / EN 61034 |
IEC 60332-1 / IEC 60332-3 / IEC 60754-1 / IEC 60754-2 / IEC 61034 |
H05Z-K & H07Z-K CABLE CONSTRUCTION
Conductor | Flexible copper (Class 5) |
Insulation | Low Smoke Zero Halogen (LSZH) Type EI5 |
The 2491B / 6701B’s Type EI5 thermoset LSZH insulation makes this range suitable for use in environments where smoke and toxic fumes arising in a fire may threaten life or equipment. It is therefore generally for use in public areas and government and commercial buildings.
H05Z-K & H07Z-K CABLE SIZES AND VOLTAGE RATING
Sizes | Voltage rating | |
---|---|---|
H05Z-K | 0.5mm2 to 1mm2 | 300/500V |
H07Z-K | 1.5mm2 to 240mm2 | 450/750V |
2491B CABLE DIMENSIONS
Commonly requested 2491B cable sizes include:
Nominal Cross-Sectional Area | Nominal Overall Diameter mm | Nominal Weight kg/km |
---|---|---|
0.5mm2 | 2.2 | 8.7 |
0.75mm2 | 2.5 | 11.3 |
1.0mm2 | 2.7 | 13.9 |
1.5mm2 | 3.1 | 19.3 |
2.5mm2 | 3.8 | 30.9 |
4mm2 | 4.4 | 44.9 |
6mm2 | 5.0 | 64.2 |
10mm2 | 6.4 | 108.2 |
16mm2 | 7.8 | 163.4 |
25mm2 | 9.6 | 248.1 |
35mm2 | 10.9 | 340.6 |
50mm2 | 13.1 | 484.2 |
70mm2 | 14.7 | 671.0 |
95mm2 | 16.9 | 895.8 |
- Next: 16mm Bare Copper Earth Wire Cable
- Previous: N2xh, N2xh-J, N2xh-O, 0.6/1kv Solid Copper Halogen-Free and Flame-Resistant Power Cable
Contact us
Similar Or Related
-
Flexible Electric Cable V/J 1X70mm2 Copper PVC Insulated Wire for 90kV HV Substation
-
#4AWG XHHW-2 Annealed Copper Conductor XLPE Insulation Cable 600 Volts
-
300MCM XHHW-2 Annealed Copper Conductor XLPE Insulation Cable 600 Volts
-
6181Y 1X16mm2 PVC Insulated and Sheathed Wiring Cable BS 6004 300/500V
-
Copper PVC Indualted PVC Sheathed Flexible LSZH Electric Wire Cable