Product Description

MV-90, Copper Tape Shield Power Cable, 25 KV, 3/C, CU/XLPE/CTS/PVC (ICEA S-93-639/NEMA WC71/UL 1072)
Features

UL Listed as MV-90. Rated as Sunlight Resistance for CT use, 1/0 AWG and larger. Oil Resistance I jacket. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

Application
Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.

Standards
UL 1072: Medium Voltage Power Cables.
ICEA S-93-639/NEMA WC74: 5 kV – 46 kV Shielded Power Cables.
ICEA S-97-682: Standard for Utility Shielded Power Cables Rated 5 kV- 46 kV.
AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.

Specifications
Maximum operating voltage: 5 kV to 35 kV 100% and 133% IL
Maximum conductor operation temperatures:
Wet and dry locations: Normal: 90 °C, Emergency: 130 °C, Short Circuit: 250 °C

Engineering Information
1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset crosslinked polyethylene (XLPE).
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap.
6. Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
7. Jacket: Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.

100% Insulation Levels (260 mil) 133% Insulation Levels (320 mil)
Size Number of Strands Conductor Nominal Jacket Thickness Approximate Outside Diameter Approximate Net Weight Jacket Thickness Approximate Outside Diameter Approximate Net Weight
Copper Aluminum Copper Aluminum
AWG of kcmil in mil in lb/kft mil in lb/kft
1 19 0.3 110 2.33 2766 2210
1/0 19 0.34 110 2.41 3073 2372 110 2.73 3594 2892
2/0 19 0.38 110 2.5 3474 2590 140 2.88 4189 3306
3/0 19 0.42 110 2.65 4026 2911 140 2.98 4674 3559
4/0 19 0.48 140 2.83 4769 3365 140 3.10 5263 3859
250 37 0.52 140 2.95 5303 3642 140 3.22 5815 4153
300 37 0.57 140 3.06 5965 3974 140 3.33 6492 4500
350 37 0.62 140 3.16 6588 4262 140 3.42 7129 4803
400 37 0.66 140 3.25 7196 4541 140 3.52 7751 5095
500 37 0.74 140 3.41 8438 5118 140 3.68 9017 5696
600 61 0.81 140 3.6 9617 5630 140 3.94 10405 6418
750 61 0.91 140 3.88 11577 6600 140 4.15 12224 7246