Mv-105, Power Cable, 25 Kv, 3/C, Cu/Epr/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072)

Mv-105, Power Cable, 25 Kv, 3/C, Cu/Epr/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072)

Mv-105, Power Cable, 25 Kv, 3/C, Cu/Epr/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072)

MV-105

Construction, Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC Cable

Rubber

CPE

Round Wire

Bare Copper Wire

ISO, CCC

Mv-105

Boan

25 Kv

3

1 AWG-500 Mcm

B

Tinned Copper Tape

DingAn

Heated Steel-Wooden Drum/Steel Drum

SGS

Jiangsu Yixing, China

8544601200

Product Description

MV-105, Power Cable, 25 KV, 3/C, Cu/EPR/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072)

Features
UL Listed as MV-105. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

Application
Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry
locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.

Standards
UL 1072: Medium Voltage Power Cables.
ICEA S-93-639/NEMA WC74: 5 kV – 46 kV Shielded Power Cables.
ICEA S-97-682: Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.
AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV- 46 kV.

Specifications
Maximum operating voltage: 5 kV to 25 kV 100% and 133% IL
Maximum conductor operation temperatures: Wet and dry locations, Normal: 105°C, Emergency: 140°C, Short Circuit: 250°C

Engineering Information
1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset ethylene propylene rubber (EPR). On request, Amorphous EPR.
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Soft annealed tinned copper tape, 5 mil thick, 25% minimum overlap.
6. Grounding (Optional): One or three tinned copper or covered conductors cabled with phase conductors.
7. Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
8. Jacket: Black sunlight resistance and flame retardant chlorinated polyethylene (CPE) compound.

100% and 133% Insulation Levels (90 mil)
Size Number of Strands Conductor Nominal Jacket Thickness Approximate Outside Diameter Approximate Net Weight
Copper Aluminum
AWG of kcmil in mil in lb/kft
1 19 0.3 110 2.39 3098 2543
1/0 19 0.34 110 2.47 3424 2723
2/0 19 0.38 110 2.55 3816 2933
3/0 19 0.42 110 2.7 4426 3310
4/0 19 0.48 140 2.89 5217 3813
250 37 0.52 140 3.01 5817 4156
300 37 0.57 140 3.12 6469 4478
350 37 0.62 140 3.22 7118 4792
400 37 0.66 140 3.31 7794 5138
500 37 0.74 140 3.47 9034 5714