Multicore Underground Electrical Armoured Cable Power Cable 25mm 35mm 50mm 70mm 95mm 120mm 185mm 240mm 300mm

Multicore Underground Electrical Armoured Cable Power Cable 25mm 35mm 50mm 70mm 95mm 120mm 185mm 240mm 300mm

Multicore Underground Electrical Armoured Cable Power Cable 25mm 35mm 50mm 70mm 95mm 120mm 185mm 240mm 300mm

electrical armoured cable

Construction, Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC & AC

PVC

PVC

Round Wire

Bare Copper Wire

ISO, CCC, CE

Yjv Yjv22 Yjv32

Yifang

Multi Cores

IEC/Bs/Ieca

Yifang cable

Drum, Steel Drum

CE, SGS

Zhengzhou Henan

8544492100

Product Description

Multicore underground electrical armoured cable power cable 25mm 35mm 50mm 70mm 95mm 120mm 185mm 240mm 300mm

Application and Description:

0.6/1KV, copper conductor, XLPE/PVC insulated power cable is for Iindustrial wiring and mains distribution. Can be laid direct in the ground, or in ducts, clipped to surface, on trays or in free air. May be embedded in concrete.

Standards: IEC 60502 / BS 5467 / DIN / ICEA

Design

Conductor: Stranded circular copper – class 2 according to IEC 60228 / BS EN 60228: 2005

Cores: 1C, 2C, 3C, 4C, 5C, 3C+1E, 4C+1E, 3C+2E

Insulation: XLPE / PVC

Filler: Laying up with fillers

Inner sheath: PVC / LSZH

Armour: Steel or steel tapes ( aluminium wires or aluminum tape can be customized)

Outer sheath: PVC / LSZH

Rated Voltage Uo/U (Um): 0.6/1 KV

Range of Nominal cross section: 1.5 mm2 ~ 630 mm2

8AWG~4/0AWG, 300MCM, 500MCM, 750MCM, 1000MCM

Mechanical characteristics:

Mechanical resistance to impacts: Excellent

Cable flexibility: Rigid

Usage characteristics:

Max. Conductor temperature in service: 70° C(PVC insulation), 90° C(XLPE insulation)

Short-circuit max. Conductor temperature: 250° C

Operating temperature, range: -25…60° C

Weather resistance: Very good

Flame retardant: C2, NF C 32-070

Chemical resistance: Accidental

Water proof: Intermittent

Packaging: Cut to length

Dear friends, we can design and produce power cable with International and national standards according to your request.

Type Description Number of cores Nominal cross section of conductor
VV32 CU/PVC/SWA/PVC Power Cable 1, 2, 3, 4, 3+1,
5, 4+1, 3+2
1.5~1000mm 2
VLV32 AL/PVC/SWA/PVC Power Cable
VV72 CU/PVC/Non-magnetic SWA or AWA/PVC Power Cable 1 1.5~1000mm 2
VLV72 AL/PVC/Non-magnetic SWA or AWA/PVC Power Cable
VY33 CU/PVC/SWA/PE Power Cable 1, 2, 3, 4, 3+1,
5, 4+1, 3+2
1.5~1000mm 2
VLY33 AL/PVC/SWA/PE Power Cable
Z-VV32 CU/PVC/SWA Flame-retardant Power Cable 1, 2, 3, 4, 3+1,
5, 4+1, 3+2
1.5~1000mm 2
Z-VLV32 AL/PVC/SWA Flame-retardant Power Cable
N-VV32 CU/PVC/SWA Fire-resistant Power Cable 1, 2, 3, 4, 3+1,
5, 4+1, 3+2
1.5~1000mm 2

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.