Low Voltage 600V Triplex Service Cable 2X4AWG+4AWG
Low Voltage 600V Triplex Service Cable 2X4AWG+4AWG
triplex cable 2x4awg+4awg
Insulated
Stranded
Overhead, Heating
Aluminum or Aluminum Alloy or Aluminum & Steel
No
XLPE or PE or PVC
Round Wire
Overhead
ISO9001, CE, CCC
Jytop
Black,Red,Yellow,Blue,Brown,Green
2X4AWG
3X14AWG
2X4AWG+4AWG
Triplex Cable
Triplex Cable 2X4AWG+4AWG
0.6/1kv
Manufacturer
CE, ISO9001
Oyster
jytop
Packed in 500m Coils or in Wooden Reels
based on ASTM or IEC or NF standards
Zhengzhou, China
8544492100
Product Description
Triplex cable, Triplex service cabe, 2x4awg+4awg
Triplex Service Drop-Aluminum Conductor
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
Standards
ASTM B-230, B-231, B-232 and B-339 & ICEA S-76-474
NOTE:
If you want to know more details about this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.
Code Name |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft(lbs) |
Ampacity (Amps) | |||||||
Size AWG |
Stranding | Insulation thickness (mls) |
Size AWG |
Stranding | Breaking strength (lbs) |
XLP | POLY | XLP | POLY | ||
6201 ALLOY NEUTRAL-MESSENGER | |||||||||||
Minex | 6 | solid | 45 | 6 | 7 | 1,110 | 106.6 | 102.9 | 85 | 70 | |
Hippa | 6 | 7/w | 45 | 6 | 7 | 1,110 | 113.2 | 105.7 | 85 | 70 | |
Prawn | 4 | solid | 45 | 4 | 7 | 1,760 | 158.4 | 154.1 | 115 | 90 | |
Barnacles | 4 | 7/w | 45 | 4 | 7 | 1,760 | 168.3 | 158.2 | 115 | 90 | |
Shrimp | 2 | 7/w | 45 | 2 | 7 | 2,800 | 253.7 | 239.7 | 150 | 120 | |
Gammarus | 1/0 | 7/w | 60 | 1/0 | 7 | 4,460 | 411.7 | 386.0 | 205 | 160 | |
Leda | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 402.7 | 386.0 | 205 | 160 | |
Dungenese | 2/0 | 7/w | 60 | 2/0 | 7 | 5,390 | 506.8 | 476.3 | 235 | 185 | |
Cyclops | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 495.3 | 476.3 | 235 | 185 | |
Flustra | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 611.4 | 589.1 | 275 | 215 | |
Lepas | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 757.1 | 730.5 | 315 | 245 | |
6201 ALLOY REDUCED NEUTRAL-MESSENGER | |||||||||||
Artemia | 4 | solid | 45 | 6 | 7 | 1,110 | 141.4 | 137.1 | 115 | 90 | |
Crab | 4 | 7/w | 45 | 6 | 7 | 1,110 | 151.3 | 141.2 | 115 | 90 | |
Solaster | 2 | 7/w | 45 | 4 | 7 | 1,760 | 226.6 | 212.6 | 150 | 120 | |
Sandcrab | 1/0 | 7/w | 60 | 2 | 7 | 2,800 | 368.8 | 343.1 | 205 | 160 | |
Echinus | 1/0 | 19/w | 60 | 2 | 7 | 2,800 | 358.8 | 343.1 | 205 | 160 | |
Crayfish | 2/0 | 7/w | 60 | 1 | 7 | 3,530 | 452.6 | 422.5 | 235 | 185 | |
Sipho | 2/0 | 19/w | 60 | 1 | 7 | 3,530 | 441.0 | 422.5 | 235 | 185 | |
Fulgar | 3/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 543.4 | 521.1 | 275 | 215 | |
Arca | 4/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 671.2 | 644.6 | 315 | 245 | |
Code Name |
Phase Conductors | Bare Neutral | Weight Per 1000 ft.(lbs) |
Ampacity(Amps) | |||||||
Size AWG or MCM |
Stranding | Insulation thickness (mls) |
Size (AWG) |
*Stranding | Rated strength (lbs) |
XLP | Poly | XLP | Poly | ||
AAC NEUTRAL-MESSENGER | |||||||||||
Haiotis | 6 | solid | 45 | 6 | 7 | 563 | 102.5 | 98.8 | 85 | 70 | |
Patella | 6 | 7/w | 45 | 6 | 7 | 563 | 109.1 | 101.6 | 85 | 70 | |
Fusus | 4 | solid | 45 | 4 | 7 | 881 | 151.9 | 147.6 | 115 | 90 | |
Oyster | 4 | 7/w | 45 | 4 | 7 | 881 | 161.8 | 151.7 | 115 | 90 | |
Clam | 2 | 7/w | 45 | 2 | 7 | 1,350 | 243.2 | 229.2 | 150 | 120 | |
Murex | 1/0 | 7/w | 60 | 1/0 | 7 | 1,990 | 395.1 | 369.4 | 205 | 160 | |
Purpura | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 386.1 | 369.4 | 205 | 160 | |
Nassa | 2/0 | 7/w | 60 | 2/0 | 7 | 2,510 | 485.8 | 455.3 | 235 | 185 | |
Melita | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 585.2 | 562.9 | 275 | 215 | |
Portunus | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 723.9 | 697.3 | 315 | 245 | |
Nannynose | 336.4 | 19/w | 80 | 336.4 | 19 | 6,146 | 1160.4 | 1118.0 | 420 | 325 | |
WITH FULL SIZE ACSR MESSENGER | |||||||||||
Paludina | 6 | solid | 45 | 6 | 6/1 | 1,190 | 114 | 113 | 85 | 70 | |
Voluta | 6 | 7/w | 45 | 6 | 6/1 | 1,190 | 120 | 113 | 85 | 70 | |
Whelk | 4 | solid | 45 | 4 | 6/1 | 1,860 | 169 | 165 | 115 | 90 | |
Periwinkle | 4 | 7/w | 45 | 4 | 6/1 | 1,860 | 176 | 172 | 115 | 90 | |
Conch | 2 | 7/w | 45 | 2 | 6/1 | 2,850 | 267 | 261 | 150 | 120 | |
Neritina | 1/0 | 7/w | 60 | 1/0 | 6/1 | 4,380 | 530 | 419 | 205 | 160 | |
Cenia | 1/0 | 19/w | 60 | 1/0 | 6/1 | 4,380 | 426 | 416 | 205 | 160 | |
Runcina | 2/0 | 7/w | 60 | 2/0 | 6/1 | 5,310 | 530 | 519 | 235 | 185 | |
Triton | 2/0 | 19/w | 60 | 2/0 | 6/1 | 5,310 | 526 | 514 | 235 | 185 | |
Cherrystone | 3/0 | 7/w | 60 | 3/0 | 6/1 | 6,620 | 656 | 643 | 250 | 200 | |
Mursia | 3/0 | 19/w | 60 | 3/0 | 6/1 | 6,620 | 650 | 638 | 250 | 200 | |
Razor | 4/0 | 7/w | 60 | 4/0 | 6/1 | 8,350 | 814 | 799 | 315 | 245 | |
Zuzara | 4/0 | 19/w | 60 | 4/0 | 6/1 | 8,350 | 805 | 792 | 315 | 245 | |
Limpet | 336.4 | 19/w | 80 | 336.4 | 18/1 | 8,680 | 1209 | 1167 | 420 | 325 | |
Code Name |
Phase Conductors | Bare Neutral | Weight Per 1000 ft.(lbs) |
Ampacity(Amps) | |||||||
SizeAWGor MCM | Stranding | Insulation thickness (mls) |
Size (AWG) |
Stranding | Rated strength (lbs) |
XLP | Poly | XLP | Poly | ||
WITH ACSR REDUCED SIZE MESSENGER | |||||||||||
Scallop | 4 | Solid | 45 | 6 | 6/1 | 1,190 | 148 | 144 | 115 | 90 | |
Strombus | 4 | 7/w | 45 | 6 | 6/1 | 1,190 | 158 | 148 | 115 | 90 | |
Cockle | 2 | 7/ w | 45 | 4 | 6/1 | 1,860 | 233 | 227 | 150 | 120 | |
Janthina | 1/0 | 7/ w | 60 | 2 | 6/1 | 2,850 | 376 | 365 | 205 | 160 | |
Ranella | 1/0 | 19/ w | 60 | 2 | 6/1 | 2,850 | 372 | 362 | 205 | 160 | |
Cavolinia | 2/0 | 7/ w | 60 | 1 | 6/1 | 3,550 | 462 | 451 | 235 | 185 | |
Clio | 2/0 | 19/ w | 60 | 1 | 6/1 | 3,550 | 458 | 446 | 235 | 185 | |
Sanddollar | 3/0 | 7/ w | 60 | 1/0 | 6/1 | 4,380 | 570 | 557 | 275 | 215 | |
Aega | 3/0 | 19/ w | 60 | 1/0 | 6/1 | 4,380 | 565 | 552 | 275 | 215 | |
Cuttlefish | 4/0 | 7/ w | 60 | 2/0 | 6/1 | 5,310 | 706 | 691 | 315 | 245 | |
Cerapus | 4/0 | 19/ w | 60 | 2/0 | 6/1 | 5,310 | 699 | 684 | 315 | 245 | |
Cowry | 336.4 | 19/ w | 80 | 4/0 | 6/1 | 8,350 | 1135 | 1093 | 420 | 325 |