3X35mm2+E Aluminium Conductor XLPE Insulation ABC Aerial Bundled Cable

3X35mm2+E Aluminium Conductor XLPE Insulation ABC Aerial Bundled Cable

3X35mm2+E Aluminium Conductor XLPE Insulation ABC Aerial Bundled Cable

10mm2 16mm2 25mm2 35mm2 50mm2

Insulated

Stranded

Overhead, Underground

Aluminum

HDPE

XLPE or PE or PVC

Round Wire

Overhead

ISO9001, CE

Jytop

IEC,BS, ASTM, Sans, AS/NZS

Duplex, Triplex, Quadruplex, Multiplex

Overhead Power Transmission Line Distribution

jytop

Packed in 500m/Rolls

1 core, 2 core, 3 core

Zhengzhou, China

8544492100

Product Description

3x35mm2+E Aluminium Conductor XLPE Insulation ABC Aerial Bundled Cable

ABC cable is widely used in the overhead power transmission line distribution system in the country, and it’s one of the main products for forming power system.

Construction:
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.

Applications
a. Duplex Service Drop
Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum.
b. Triplex Service Drop
Application: To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation.
c. Quadruplex Service Drop.
Used to supply 3 phase power, usually from a polemounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors.

Standard
ANSI/ICEA S-76-474, NF C 33-209, AS3560-1-2000, IEC 60228, and ect.

Specification

Duplex service drop
Code Name Phase conductor Bare Neutral Message Nominal Weight ( kg/km ) Allowable Ampacity
Size & No.of wires Insulation Thick(mm) Nominal Diameter (mm) Size & No.of wires Rated Strength (kg) XLPE Aluminum ( A )
Bare OD
AAC
Pekingese 6-Solid 1.14 4.1 6.4 6-7 255 20.8 72.9 78
Collie 6-7 1.14 4.6 6.9 6-7 255 23.8 72.9 78
Cocker 6-7 1.52 4.6 7.7 6-7 255 32.7 72.9 78
Dachshund 4-Solid 1.14 5.2 7.5 6-7 400 26.8 114.6 103
Spaniel 4-7 1.14 5.9 8.2 6-7 400 29.8 116.1 103
Cairn 4-7 1.52 5.9 8.9 6-7 400 40.2 116.1 103
Doberman 2-7 1.14 7.4 9.7 2-7 612 38.7 184.5 136
Airedale 1-19 1.52 8.4 11.5 1-7 56.5 233.6 158
Basset 1/0-7 1.52 9.3 12.4 1/0-7 903 64 294.7 182
Malemure 1/0-19 1.52 9.4 12.5 1/0-7 903 64 294.7 182
AAAC
Chihuahua 6-Solid 1.14 4.1 6.4 6-7 499 20.8 72.9 78
VIzsla 6-7 1.14 4.6 6.9 6-7 499 23.8 72.9 78
Harrier 4-Solid 1.14 5.2 7.5 4-7 798 26.8 116.1 103
Whippet 4-7 1.14 5.9 8.2 4-7 798 29.8 116.1 103
Schnauzer 2-7 1.14 7.4 9.7 2-7 1270 38.7 184.5 136
Afghan 1/0-7 1.52 9.3 12.4 1/0-7 2023 64 296.1 182
Hocler 1/0-19 1.52 9.4 12.5 1/0-7 2023 64 296.1 182
ACSR
Setter 6-Solid 1.14 4.1 6.4 6/6/01 540 20.8 72.9 78
Shepherd 6-7 1.14 4.6 6.9 6/6/01 540 23.8 72.9 78
Retriever 6-7 1.52 4.6 7.7 6/6/01 540 32.7 72.9 78
Eskimo 4-Solid 1.14 5.2 7.5 4/6/01 844 26.8 114.6 103
Terrier 4-7 1.14 5.9 8.2 4/6/01 844 29.8 116.1 103
Yorkshirc 4-7 1.52 5.9 8.9 4/6/01 844 40.2 116.1 103
Chow 2-7 1.14 7.4 9.7 2/6/01 1293 38.7 184.5 136
Labrador 1-19 1.52 8.4 11.5 1/6/01 1610 56.5 233.6 158
Bloodhound 1/0-7 1.52 9.3 12.4 1/0-6/1 1987 64 294.7 182
Bull 1/0-19 1.52 9.4 12.5 1/0-6/1 1987 64 294.7 182

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.