Low and Medium Voltage Single Core Cu/Al XLPE Insulated Armored Power Cable
Product Description
Low and Medium Voltage Single core CU/AL XLPE Insulated Armored Power Cable
Number of cores:
1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.
Nominal Section
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800mm2
Standard:
IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer’s request.
The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35
Application:
Power cable are most suitable for direct burial or for installation on trays or ducts, Where there is
a risk of mechanical damage, armoured cables should be used.
TYPE |
NAME |
Main Application |
|
CU core |
AL core |
||
YJV/YJY |
YJLV/YJLY |
XLPE insulated,PVC/PE sheathed power cable |
For laying indoor ,tunnel,canal and underground. |
YJV22/YJV23 |
YJLV22/YJLV23 |
XLPE insulated,steel tape armored, |
For laying indoor ,tunnel,canal and underground. |
YJV32/YJV33 |
YJLV32/YJLV33 |
XLPE insulated,thin steel wire armored, |
For laying in shaft,water underground will large difference of level. |
YJV42/YJV43 |
YJLV42/YJLV43 |
XLPE insulated,thick steel wire armored, |
For laying in water and seabed. |
Features:
1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground.
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Alum Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
1×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 10.9 |
1×6 | 2.8 | 0.7 | 1 | 0.8 | 1.8 | 11.4 |
1×10 | 3.6 | 0.7 | 1 | 0.8 | 1.8 | 12.2 |
1×16 | 4.5 | 0.7 | 1 | 0.8 | 1.8 | 13.1 |
1×25 | 5.6 | 0.9 | 1 | 0.8 | 1.8 | 14.6 |
1×35 | 6.7 | 0.9 | 1 | 1.25 | 1.8 | 16.6 |
1×50 | 8 | 1 | 1 | 1.25 | 1.8 | 18.1 |
1×70 | 9.4 | 1.1 | 1 | 1.25 | 1.8 | 19.7 |
1×95 | 11 | 1.1 | 1 | 1.6 | 1.8 | 22 |
1×120 | 12.4 | 1.2 | 1 | 1.6 | 1.8 | 23.6 |
1×150 | 13.8 | 1.4 | 1 | 1.6 | 1.8 | 25.4 |
1×185 | 15.3 | 1.6 | 1 | 1.6 | 1.8 | 27.4 |
1×240 | 17.5 | 1.7 | 1 | 1.6 | 1.9 | 29.9 |
1×300 | 19.5 | 1.8 | 1 | 2 | 2 | 33.1 |
1×400 | 22.6 | 2 | 1.2 | 2 | 2.2 | 37.3 |
1×500 | 25.2 | 2.2 | 1.2 | 2 | 2.3 | 40.5 |
- Next: H03VV-F Copper PVC Insulated Cable Flexible Electrical Building Wire H05VV-F