H03VV-F Copper PVC Insulated Cable Flexible Electrical Building Wire H05VV-F

H03VV-F Copper PVC Insulated Cable Flexible Electrical Building Wire H05VV-F

H03VV-F Copper PVC Insulated Cable Flexible Electrical Building Wire H05VV-F

h05vv-f

Insulated

Stranded

Underground

Copper

None

PVC

Round Wire

Refractory

ISO9001, UL

Jytop

0.6/1kv Copper PVC Insulated Electrical Flexible C

ASTM, AS/NZS, BS, CSA, DIN, IEC…

Black, Red, Yellow, Blue, Brown, Green

0.6/1kv

Ce, ISO 9001

JYTOP

Drum or Reel

based on ASTM or IEC or BS or NF standards

Zhengzhou, China

8544492100

Product Description

H03vv-f Copper PVC Insulated cable Flexible Electrical building wire h05vv-f

PVC Insulated Electric Wire for Equipment and Household
Conductor:: Copper/Aluminum/Copper clad aluminum
Insulation:: PVC/PE/HDPE/XLPE
Apply voltage:: 300/300V 300/500V 450/750V
Ambient Temperature:: Above 0°C
Operation temperature:: For PVC insulated wire, Operating temperature should not exceed 70°C except for Type 08.; Type 08 will allow 105°C.

1. Operating Characteristics: Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 70° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed:
Nominal cross section of conductor ≤ 300mm2: 160° C;
Nominal cross section of conductor >300mm2: 140° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For multi-core cable: Not less than 15 times of the diameter of cable

2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or in conduit, unable to bear external mechanical force.

3. Manufacturing Standards
IEC 60502-1 & Chinese national standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.

PVC Building wire Technical Parameters:

Size of conductor Nominal thickness of insulation mm Mean overall diameter Upper limit mm Approx.net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires no./mm
1.0 32/0.20 0.6 3.0 16
1.5 30/0.25 0.7 3.5 21
2.5 50/0.25 0.8 4.2 33
4 56/0.30 0.8 4.8 50
6 84/0.30 0.8 6.3 70
10 80/0.40 1.0 7.6 120
16 126/0.40 1.0 8.8 175
25 196/0.40 1.2 11.0 290
35 276/0.40 1.2 12.5 400
50 396/0.40 1.4 14.5 565
70 360/0.50 1.4 17.0 770
95 475/0.50 1.6 19.0 1010
120 608/0.50 1.6 21.0 1260
150 756/0.50 1.8 23.5 1580
185 925/0.50 2.0 26.0 1900
240 1221/0.50 2.2 29.5 2500