High Voltage Al/XLPE 11kv ABC Cable, Malemute

High Voltage Al/XLPE 11kv ABC Cable, Malemute

High Voltage Al/XLPE 11kv ABC Cable, Malemute

Malemute

Insulated

Stranded

Overhead, Underground

Aluminum

PVC

XLPE

Round Wire

Overhead Power Transmission

ISO9001, CE, UL, CCC, RoHS, VDE

Yifang

16mm2,25mm2,35mm2,50mm2,70mm2,95mm2,120mm2,150mm2

XLPE

Aluminum Tape Shield

PVC

Stranded Aluminum Wire

Insulated Stranded Steel Wire/ AAAC/ACSR

Zhengzhou Yifang Cable Co., Ltd.

Wooden Drum

ISO CE SABS

Henan, China

8544492100

Product Description


11KV High Voltage ABC Cable Aerial Bundled XLPE Cable:
a) Conductor: Hard Drawn Aluminum
b) Conductor Screen: Semi-Conductive Compound
c) Insulation: Cross-Linked Polyethylene
d) Insulation Screen: Sem-conductive Compound
e) Metallic Screen: Copper Type
f) Binder: Polyester Non- Woven Type
g) Outer Sheath: Black PVC (ST2)+ Ultra Violet Resistant
0.6/1kv ABC Aerial Bundled XLPE Cable :
Phase Conductor:
a) Conductor: Aluminum
b) Insulation: Cross-lined Polyethylene
Messenger:
a) Conductor : Aluminum Alloy, Aluminum Conductor, Aluminum Conductor Steel Reinforced
b) Insulation: Cross-lined Polyethylene or None
Street Lighting:
a) Conductor: Aluminum
b) Insulation: Cross-lined Polyethylene or None

Applications:
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user’s service head where connect to the service entrance cable. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75° C for PE insulated Conductors or 90° C for crosslinked polyethylene (XLPE) insulated conductors.

Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.

Installation:
For service at 600 volts or less (phase to phase) at a maximum conductor temperature of 75C for Polyethylene insulation or 90C for Cross-Linked (XLPE) insulation

Specifications
Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
B-230 Aluminum Wire, 1350-H19 for electrical purposes
B-231 Aluminum Conductors, concentric-lay-stranded
B-232 Aluminum Conductors, concentric-lay-stranded, coated steel reinforced(ACSR)
B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
B-498 Zinc-coated Steel Core Wire for Aluminum Conductors, steel reinforced(ACSR/AZ)
Triplex Service Drop cable meets or exceeds all aplicable requierements of
ANSI/ICEA S-76-474.

Code Word Phase conductor Bare Neutral Messenger Nominal Lay Length Weight Per 1000ft. (lbs. ) Allowable Ampacities+
Size
(AWG)
Stranding Insul. Thick.
(Mils)
Size
(AWG)
Stranding Rated Strength
(lbs. )
inches XLP POLY XLP POLY
AAC Neutral-messenger
Pekingese 6 1 45 6 7 563 10.36 61 61 85 70
Collie 6 7 45 6 7 563 10.36 64 64 85 70
Dachshund 4 1 45 4 7 881 10.36 92 92 115 90
Spaniel 4 7 45 4 7 881 10.36 96 96 115 90
Doberman 2 7 45 2 7 1350 14.88 147 147 150 120
Malemute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160