750mcm Aluminum Xhhw-2 600V XLPE Insulation Xhhw-2 Service Wire

750mcm Aluminum Xhhw-2 600V XLPE Insulation Xhhw-2 Service Wire

750mcm Aluminum Xhhw-2 600V XLPE Insulation Xhhw-2 Service Wire

xhhw-2 aluminum

Insulated

Stranded

Overhead, Heating, Underground

Aluminum

Crosslinking

XLPE

Round Wire

Flame Retardant

ISO9001, CCC

Hongda

Compact Soft Drawn Bare 8000 Series Aluminum

Hongda

100m/Roll, 500FT/Roll

8awg to 1000mcm

Henan, China

8544492100

Product Description

XHHW Wire Overview

XHHW is an alphabetism or initialism which stands for "XLPE (cross-linked polyethylene) High Heat-resistant Water-resistant." XHHW is a designation for a specific insulation material, temperature rating, and condition of use (suitable for wet locations) for electrical wire and cable.

Wires with XHHW insulation are commonly used in the alternating current (AC) electrical distribution systems of commercial, institutional, and industrial buildings and installations, usually at voltage levels (potential difference or electromotive force) ranging from 110-600 Volts. This type of insulation is used for both copper and aluminum conductors which are either solid or stranded, depending on size.

According to Underwriters Laboratories (UL) Standard 44, XHHW insulation is suitable for use in dry locations up to 90° C (194° F), or wet locations up to 75° C (167° F).

XHHW-2 insulation, which is similar to XHHW, is suitable for use in dry or wet locations up to 90° C (194° F).

XHHW / XHHW-2 electrical conductor insulation is governed by the following Industry Standards: 

• UL 44
• CSA c22.2. No38
• ASTM-B3
• ASTM-B8
• ASTM-B800
• ASTM-B801
• NFPA 70 -2008 (NEC code)
• U.S. Federal Specification J-C 30B
• NEMA WC70/ICEA S-95-658

Conductors: Compact soft drawn bare 8000 series aluminum, with Class B stranding per ASTM.
Insulation: Abrasion, heat and moisture resistant cross-linked polyethylene insulation (XLPE), low coefficient of friction, "slippery" or "slick" material. It is available in ten solid colors.

Part Number Size AWG/KCM Stranding Conductor Diameter (inches) Insulation Thickness (inches) Overall Diameter (inches) Weight (Ibs/1000′) Ampacity at 90ºC*
8 XHHW-2-ALUM 8 7 0.134 0.045 0.227 30 45
6 XHHW-2-ALUM 6 7 0.169 0.045 0.262 42 55
4 XHHW-2-ALUM 4 7 0.213 0.045 0.306 58 75
2 XHHW-2-ALUM 2 7 0.268 0.045 0.361 86 100
1 XHHW-2-ALUM 1 18 0.299 0.055 0.412 110 115
1/0 XHHW-2-ALUM 1/0 18 0.335 0.055 0.449 134 135
2/0 XHHW-2-ALUM 2/0 18 0.378 0.055 0.489 163 150
3/0 XHHW-2-ALUM 3/0 18 0.423 0.055 0.536 200 175
4/0 XHHW-2-ALUM 4/0 18 0.476 0.055 0.588 247 205
250 XHHW-2-ALUM 250 35 0.52 0.065 0.653 296 230
300 XHHW-2-ALUM 300 35 0.571 0.065 0.703 359 260
350 XHHW-2-ALUM 350 35 0.614 0.065 0.749 401 280
400 XHHW-2-ALUM 400 35 0.657 0.065 0.792 453 305
500 XHHW-2-ALUM 500 35 0.736 0.065 0.869 556 350
600 XHHW-2-ALUM 600 58 0.816 0.080 0.979 679 385
700 XHHW-2-ALUM 700 58 0.877 0.080 1.04 782 425
750 XHHW-2-ALUM 750 58 0.909 0.080 1.071 833 435
900 XHHW-2-ALUM 900 58 0.999 0.080 1.169 983 480
1000 XHHW-2-ALUM 1000 58 1.059 0.080 1.223 1090 500

All values are nominal and subject to correction
* Ampacities for not more than three conductors in raceway, based on ambient temperature of 30ºC per Table 310-15(B)(16) of the 2017 National Electrical Code

The different letters in XHHW wire denote particular properties of the cable:

X for Cross-Linked
HH for High Heat-Resistant, and
W for Water Resistant.

These characteristics along with the wide range of sizes make XHHW an ideal choice for residential, commercial, and industrial buildings, as well as for installations of many types.

Contact information:
Any needs or question ,please contact us ,we will be more pleasure to service you.
We are looking forward to your inquiry and nice cooperaton.
For more information, don’t hesitate to call Vivian on +86-18339931106  