0.6/1kv Nh-Yjv22 N2xby 4 Cores Cu/Mica/XLPE/Dsta/PVC Power Cable

0.6/1kv Nh-Yjv22 N2xby 4 Cores Cu/Mica/XLPE/Dsta/PVC Power Cable

0.6/1kv Nh-Yjv22 N2xby 4 Cores Cu/Mica/XLPE/Dsta/PVC Power Cable

n2xby cable

Construction, Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC Cable

XLPE

PVC

Round Wire

Bare Copper Wire

ISO, CCC

SGS

N2xby Cable

Hongda

0.6/1kv, 600/1000V, 1.1kv

Hongda or OEM

500m or 1000m Per Drum

1.5-300 mm2

China

8544492100

Product Description

0.6/1kv NH-YJV22 N2XBY 4 cores Cu/Mica/XLPE/DSTA/PVC power cable

N2XBY 4 x (1.5-300) mm² 0.6/1 kV

Cu / Mica / XLPE / DSTA / PVC
(Copper Conductor, Mica Tape, XLPE Insulated, Double Galvanized Steel Tape Armor, PVC Sheathed)
Standard Specification : IEC 60502-1 and IEC 60331

Application
For wiring of fire resistant safety circuits, such as fire alarm system, emergency lighting and power, public address and emergency voice communication systems in highrise building, control and instrumentation services in industrial, commercial and residential complexes.

Special Features on Request :
• Oil Resistance
• UV Resistance
• Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
• Anti Termite
• Anti Rodent
• Low Smoke Zero Halogen

Note :
Conductor Shape
1.5 – 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 – 300 sqmm supplied in compacted circular stranded (cm) conductor shape

Standard Packing
1.5 – 50 sqmm supplied in wooden drum @ 1000 m
70 – 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%

Construction Data

Nom. Cross Section Area Overall Diameter Cable Weight
approx. approx.
mm² mm kg/km
1.5 17.6 423
2.5 18.7 499
4 20.0 603
6 22.0 734
10 24.5 970
16 25.5 1,206
25 29.5 1,689
35 32.5 2,164
50 37.0 3,115
70 42.5 4,163
95 46.5 5,334
120 51.5 6,547
150 57.0 7,897
185 62.5 9,698
240 69.5 12,255
300 75.5 14,895

Electrical Data

Conductor Inductance Current – Carrying Capacity at 30° C * Short circuit current at 1 sec
Nom. Cross Section Area DC Resistance at 20°C AC Resistance at 90°C
in air in ground
(mm²) Max. (Ω/km) Max. (Ω/km) (mH/km) Max. (A) Max. (A) Max. (kA)
1.5 12.1 15.429 0.315 27 32 0.21
2.5 7.41 9.449 0.293 36 42 0.36
4 4.61 5.878 0.275 48 55 0.57
6 3.08 3.927 0.263 60 68 0.86
10 1.83 2.334 0.248 83 91 1.43
16 1.15 1.467 0.238 110 118 2.29
25 0.727 0.927 0.240 148 152 3.58
35 0.524 0.669 0.233 183 183 5.01
50 0.387 0.494 0.232 214 210 7.15
70 0.268 0.343 0.229 269 256 10.01
95 0.193 0.247 0.224 334 309 13.59
120 0.153 0.197 0.223 386 350 17.16
150 0.124 0.160 0.224 449 395 21.45
185 0.0991 0.129 0.225 512 444 26.46
240 0.0754 0.099 0.223 604 513 34.32
300 0.0601 0.081 0.221 692 577 42.90

*Further information about rating factor for certain cable arrangement can be found on supplementary technical information