0.6/1kv N2xby Electrical Cable Low Voltage LV N2xby Electric Cable

0.6/1kv N2xby Electrical Cable Low Voltage LV N2xby Electric Cable

0.6/1kv N2xby Electrical Cable Low Voltage LV N2xby Electric Cable

N2XBY

Insulated

Stranded

Underground

Copper

PVC

XLPE

Round Wire

Underground

ISO9001, CE, CCC

Jytop

Phase 0.124 Ohm/Km & Earth 0.268 Ohm/Km

Phase 0.153 Ohm/Km & Earth 0.268 Ohm/Km

JYTOP

Packed in Reels

as per popular standards or clients's requirement

Zhengzhou, China

8544492100

Product Description

0.6/1kV N2XBY ELECTRICAL CABLE LOW VOLTAGE LV N2XBY ELECTRIC CABLE

1. Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 90 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed: 250 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 15 times of the diameter of cable
For multi-core cable: Not less than 12 times of the diameter of cable
When the armored single core cable used for Alternative Current(AC) system, the armoring material should be non-magnetic.

2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical force, but unable to bear large pulling force.

3. Manufacturing Standards
IEC 60502-1 & Chinese national standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.

NOTE:
If you want to know more details about this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.

Cable size Conductor
type
Nominal thickness of XLPE insulation(mm) Nominal
thickness
of steel tape(mm)
Nominal
thickness
of PVC or PE sheath(mm)
Approx. cable
overall diameter (mm)
Max. D.C resistance @ 20 0 C (Ω/km)
Phase
core
Earth
core
Phase
core
Earth
core
Phase
core
Earth
core
4×2.5+1.5mm 2 RE RE 0.7 0.7 0.2 1.8 15.4 7.41 12.1
4×4+2.5mm 2 RE RE 0.7 0.7 0.2 1.8 16.6 4.61 7.41
4×6+4mm 2 RE RE 0.7 0.7 0.2 1.8 17.9 3.08 4.61
4×10+6mm 2 RM RE 0.7 0.7 0.2 1.8 21.0 1.83 3.08
4×16+10mm 2 RM RM 0.7 0.7 0.2 1.8 24.0 1.15 1.83
4×25+16mm 2 SM RM 0.9 0.7 0.2 1.8 26.0 0.727 1.15
4×35+16mm 2 SM RM 0.9 0.7 0.2 1.9 27.9 0.524 1.15
4×50+25mm 2 SM SM 1.0 0.9 0.5 2.0 32.8 0.387 0.727
4×70+35mm 2 SM SM 1.1 0.9 0.5 2.2 37.0 0.268 0.524
4×95+50mm 2 SM SM 1.1 1.0 0.5 2.3 41.6 0.193 0.387
4×120+70mm 2 SM SM 1.2 1.1 0.5 2.5 45.6 0.153 0.268
4×150+70mm 2 SM SM 1.4 1.1 0.5 2.6 49.4 0.124 0.268
4×185+95mm 2 SM SM 1.6 1.1 0.5 2.8 54.9 0.0991 0.193
4×240+120mm 2 SM SM 1.7 1.2 0.5 3.0 61.0 0.0754 0.153
4×300+150mm 2 SM SM 1.8 1.4 0.5 3.2 67.0 0.0601 0.124

Tags: , ,