0.6/1kv N2xh Flame-Retardant Halogen-Free Cable for Public Buildings
Product Description
Halogen-Free Cable with Improved Fire Behaviour
Application:
Safety cables are used in all locations where a high degree of protection against fire and fire-damage has to be provided for human life and equipment and are, therefore, subject to high security requirements. These cables may be used indoors and outdoors. They may not be installed directly into the ground and into the water. This cable conforms to Safety Class II standards.
N2XH and N2XCH cables are widely used European power cables used for electricity supply for fixed installations with a voltage rating of 600/1000V in public buildings. Their flame-retardant non-corrosive (FRNC) outersheath makes them suitable for use where smoke and corrosive gases would pose a risk to human life and sensitive equipment in the event of a fire.
These cables are suitable for use in dry and damp environments, on or under plaster, on cable trays, in walls, masonry and in concrete. The N2XH and N2XCH are not suitable for direct burial without external protection against mechanical stress or water.
N2XH CABLE CONSTRUCTION:
N2XH | |
---|---|
Conductor | Up to 25mm2: Solid copper (Class 1) Above 25mm2: Stranded copper (Class 2) |
Insulation | Cross-linked Polyethylene (XLPE) Type 2XI1 |
Outersheath | Low Smoke Zero Halogen (LSZH) Type HM4 – flame retardant non-corrosive compound (FRNC) |
N2XCH CABLE CONSTRUCTION:
N2XCH | |
---|---|
Conductor | Up to 25mm2: Solid copper (Class 1) Above 25mm2: Stranded copper (Class 2) |
Insulation | Cross-linked Polyethylene (XLPE) Type 2XI1 |
Concentric conductor | Copper wires with counter helix of copper tape |
Outersheath | Low Smoke Zero Halogen (LSZH) Type HM4 – flame retardant non-corrosive compound (FRNC) |
Technical data:
Nominal voltage Uo/U | [V] | 600 / 1000 volt | |
Test voltage | [V]AC | 4000 | |
Temperature range | in motion | -5°C till +90°C | |
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | single-core style | x diameter | 15 |
multi-core style | x diameter | 12 | |
Flammability | standard | EN 50266-2-4 EN 60332-1 |
We supply the following variants of N2XH and N2XCH:
Protective conductor
N2XH-J / N2XCH-J | With protective conductor |
N2XH-O / N2XCH-O | Without protective conductor |
Conductor shapes
RE | Class 1 solid – round |
SE | Class 1 solid – sectorial |
RM | Class 2 stranded – round |
SM | Class 2 stranded – sectorial |
N2XH CABLE DIMENSION:
Number of cores and nominal cross section mm2 |
Copper figure kg/km |
Overall diameter appr. mm |
Calorific potential kWh/m |
Weight appr. kg/km |
1 x 6 RE | 60,0 | 7,8 | 0,33 | 112,0 |
1 x 16 RM | 160,0 | 9,8 | 0,46 | 226,0 |
1 x 25 RM | 250,0 | 11,4 | 0,62 | 327,0 |
1 x 35 RM | 350,0 | 12,6 | 0,71 | 429,0 |
1 x 50 RM | 500,0 | 13,8 | 0,82 | 555,0 |
1 x 70 RM | 700,0 | 15,7 | 1,00 | 765,0 |
1 x 95 RM | 950,0 | 17,4 | 1,14 | 1.024,0 |
1 x 120 RM | 1.200,0 | 19,0 | 1,32 | 1.263,0 |
1 x 150 RM | 1.500,0 | 20,9 | 1,59 | 1.542,0 |
1 x 185 RM | 1.850,0 | 23,1 | 1,91 | 1.918,0 |
1 x 240 RM | 2.400,0 | 25,6 | 2,24 | 2.466,0 |
1 x 300 RM | 3.000,0 | 28,1 | 2,58 | 3.065,0 |
2 x 1,5 RE | 30,0 | 9,3 | 0,45 | 125,0 |
2 x 2,5 RE | 50,0 | 10,1 | 0,52 | 158,0 |
3 x 1,5 RE | 45,0 | 9,7 | 0,51 | 142,0 |
3 x 2,5 RE | 75,0 | 10,6 | 0,59 | 184,0 |
3 x 4 RE | 120,0 | 11,7 | 0,70 | 247,0 |
3 x 6 RE | 180,0 | 12,8 | 0,80 | 322,0 |
3 x 10 RE | 300,0 | 14,9 | 1,02 | 480,0 |
3 x 16 RM | 480,0 | 17,7 | 1,36 | 732,0 |
3 x 25 RM | 750,0 | 24,0 | 2,25 | 1.200,0 |
3 x 35 RM | 1.050,0 | 27,0 | 2,56 | 1.600,0 |
3 x 50 RM | 1.500,0 | 29,0 | 3,19 | 1.800,0 |
3 x 50/25 SM/RM | 1.750,0 | 32,0 | 3,53 | 2.200,0 |
3 x 70/35 SM/RM | 2.450,0 | 37,0 | 4,31 | 2.950,0 |
3 x 95/50 SM | 3.216,0 | 41,0 | 5,58 | 3.900,0 |
3 x 120/70 RM | 4.300,0 | 45,0 | 6,58 | 4.800,0 |
3 x 150/70 RM | 5.200,0 | 49,0 | 7,64 | 5.750,0 |
3 x 185/95 RM | 6.500,0 | 55,0 | 9,42 | 7.200,0 |
3 x 240/120RM | 8.400,0 | 62,0 | 12,22 | 9.150,0 |
4 x 1,5 RE | 60,0 | 10,4 | 0,60 | 166,0 |
4 x 2,5 RE | 100,0 | 11,4 | 0,69 | 220,0 |
4 x 4 RE | 160,0 | 12,6 | 0,84 | 298,0 |
4 x 6 RE | 240,0 | 13,8 | 0,95 | 391,0 |
4 x 10 RE | 400,0 | 16,3 | 1,26 | 599,0 |
4 x 16 RM | 640,0 | 19,2 | 1,63 | 908,0 |
4 x 25 RM | 1.000,0 | 23,9 | 2,48 | 1.413,0 |
4 x 35 RM | 1.400,0 | 26,7 | 2,93 | 1.863,0 |
4 x 50 SM | 2.000,0 | 29,1 | 3,76 | 2.362,0 |
4 x 70 SM | 2.800,0 | 32,2 | 4,55 | 3.151,0 |
4 x 95 SM | 3.800,0 | 37,2 | 5,72 | 4.339,0 |
4 x 120 SM | 4.800,0 | 40,8 | 6,36 | 5.332,0 |
4 x 150 SM | 6.000,0 | 50,0 | 7,14 | 6.350,0 |
5 x 1,5 RE | 75,0 | 11,2 | 0,71 | 195,0 |
5 x 2,5 RE | 125,0 | 12,3 | 0,84 | 260,0 |
5 x 4 RE | 200,0 | 13,7 | 1,00 | 357,0 |
5 x 6 RE | 300,0 | 15,4 | 1,21 | 486,0 |
5 x 10 RE | 500,0 | 17,8 | 1,52 | 723,0 |
5 x 16 RE | 800,0 | 21,6 | 2,07 | 1.138,0 |
5 x 16 RM | 800,0 | 21,6 | 2,17 | 1.138,0 |
5 x 25 RM | 1.250,0 | 27,0 | 3,14 | 1.420,0 |
5 x 35 RM | 1.750,0 | 37,0 | 3,95 | 2.400,0 |
7 x 1,5 RE | 105,0 | 12,0 | 0,80 | 239,0 |
12 x 1,5 RE | 180,0 | 16,0 | 1,29 | 395,0 |
19 x 1,5 RE | 285,0 | 18,6 | 1,80 | 557,0 |
24 x 1,5 RE | 360,0 | 22,2 | 2,35 | 736,0 |
30 x 1,5 RE | 450,0 | 24,0 | 2,72 | 900,0 |
7 x 2,5 RE | 175,0 | 15,0 | 1,31 | 400,0 |
12 x 2,5 RE | 300,0 | 19,0 | 2,00 | 600,0 |
19 x 2,5 RE | 475,0 | 22,0 | 2,69 | 840,0 |
24 x 2,5 RE | 600,0 | 25,0 | 3,28 | 1.050,0 |
7 x 4 RE | 280,0 | 14,9 | 1,48 | 457,0 |
N2XH & N2XCH CABLE SELECTION:
In addition to our portfolio of European power cables we also supply British standard low voltage power cables including armoured cable BS6724 cable with its LSZH outer sheathing. Our technical has a wealth of experience in providing support in the selection of the right cable for your application. Please call to discuss your specific application.
- Next: 3.6/6kv~26/35kv Single/ Three Cores Cu/Al Swa/Sta Medium Voltage Power Cable