0.6/1kv Copper or Aluminum Conductor 4 Core 185mm2 Armoured Power Cable
Product Description
1.Manufactured according to the shandard of IEC,BS,DIN or ICEA upon requst.
2.Suitable for use in power transmission and distribution lines with rated power frequency voltage 0.6/1kV.
3.The ambient temperature for installation: ≥0°C
4.Maximun conductor temperature in normal operation:≤90°C
5.Max operating temperature of conductor when cable short-circuited(5s maximun duration): 250°C
6.Permissible bending radius:
Single cable: [20(D+d)±5%]mm
Multi cable: [15(D+d)±5%]mm
Type |
Description |
Main Application |
|
Cu core | Al core | ||
(ZR)YJV
or (ZR)YJY |
(ZR)YJLV
or (ZR)YJLY23 |
(Flame retardant) Cu, Al core XLPE insulated, PVC or PE sheathed power cable. | For laying indoor, tunnel, underground and canal. Unable to bear external mechanical pulling force and pressure during laid. |
(ZR)YJV22
or (ZR)YJY23 |
(ZR)YJLV22
or (ZR)YJLV23 |
(Flame retardant) Cu, Al core XLPE insulated, steel armoured, PVC or PE sheathed power cable. | For laying indoor, tunnel, underground and canal. Able to bear external mechanical pulling force , but unable to bear large pulling force. |
(ZR)YJLV32
or (ZR)YJLV33 |
(ZR)YJLV32
or (ZR)YJLV33 |
(Flame retardant) Cu, Al core XLPE insulated, fine steel wire armoured, PVC or PE sheathed power cable | For laying in shaft, water under ground and large difference of level, able to bear mechanical pressure and moderate pulling force. |
(ZR)YJLV42
or (ZR)YJLV43 |
(ZR)YJLV42
or (ZR)YJLV43 |
(Flame retardant) Cu, Al core XLPE insulated, thick steel wire armoured, PVC or PE sheathed power cable | For laying in the water, seabed and large difference of level, able to bear large mechanical pressure and pulling force. |
7. Suitable for under ground,can bear mechanical stress.
8. Products Parameter (structure, weight and current rating)
Type | Dia. of conductor | XLPE insulation thickness | Inner sheath thickness | Steel tape thickness | PVC jacket thickness | Approx. dia. of cable | Approx. weight of cable | Current rating of cable | |
mm2 | mm | mm | mm | mm | mm | mm | kg/km | in the air | under ground |
4*4 | 2.25 | 0.7 | 1.2 | 0.2 | 1.8 | 16 | 402 | 28 | 35 |
4*6 | 2.76 | 0.7 | 1.2 | 0.2 | 1.8 | 17 | 488 | 37 | 46 |
4*10 | 4.05 | 0.7 | 1.2 | 0.2 | 1.8 | 21 | 688 | 47 | 56 |
4*16 | 5.10 | 0.7 | 1.2 | 0.2 | 1.8 | 23 | 927 | 64 | 76 |
4*25 | 6.00 | 0.9 | 1.2 | 0.2 | 1.8 | 27 | 1367 | 84 | 98 |
4*35 | 7.00 | 0.9 | 1.2 | 0.2 | 1.8 | 30 | 1558 | 115 | 126 |
4*50 | 6.81 | 1.0 | 1.2 | 0.5 | 1.9 | 33 | 2163 | 141 | 152 |
4*70 | 8.23 | 1.1 | 1.2 | 0.5 | 2.1 | 36 | 2485 | 172 | 181 |
4*95 | 9.71 | 1.1 | 1.2 | 0.5 | 2.2 | 41 | 2813 | 218 | 222 |
4*120 | 10.95 | 1.2 | 1.3 | 0.5 | 2.4 | 44 | 2945 | 269 | 267 |
4*150 | 12.16 | 1.4 | 1.4 | 0.5 | 2.5 | 49 | 3533 | 313 | 305 |
4*185 | 13.61 | 1.6 | 1.5 | 0.5 | 2.7 | 54 | 4236 | 359 | 344 |
4*240 | 15.65 | 1.7 | 1.6 | 0.5 | 3.0 | 60 | 5625 | 405 | 383 |
4*300 | 17.53 | 1.8 | 1.7 | 0.5 | 3.1 | 66 | 6286 | 451 | 422 |
- Next: 2 Pairs Armoured Instrument Cable
- Previous: PVC Electrical Cable Insulation Copper Aluminum Conductor PVC/PVC Termite Resistant