Thhn Thwn-2 Wire Copper PVC Insulated with Nylon Jacket Cable Mtw

Thhn Thwn-2 Wire Copper PVC Insulated with Nylon Jacket Cable Mtw

Thhn Thwn-2 Wire Copper PVC Insulated with Nylon Jacket Cable Mtw

MTW or THHN or THWN-2

Insulated

Solid or Stranded

Heating

Copper

Nylon Jacket

PVC

Round Wire

Electric Wire

ISO9001, CCC, RoHS

Jytop

Red,Yellow,Blue,Brown,Green

BS, CSA, DIN, ASTM, AS/NZS,IEC…

300/600V

Single Core Cable

Max. DC Resistance @ 20 Degree 7.41 Ohm/Km

JYTOP

100m Per Coil

ASTM standards

Zhengzhou, China

8544492100

Product Description

Thhn Thwn-2 Wire Copper PVC insulated with Nylon Jacket Cable Mtw

CONSTRUCTION
THHN or THWN-2* or MTW copper conductors are annealed (soft) copper, insulated with a tough heat and moisture resistant polyvinyl chloride (PVC), over which a nylon (polyamide) or UL-listed equal jacket is applied Available in black, white, red, blue, green, yellow, brown, orange, and gray; Some colors standard, some subject to economic order quantity. Conductor sizes 2 AWG and larger listed and marked sunlight-resistant in black only

APPLICATION of Thhn electric Wire:

THHN or THWN-2* conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code 2;

When used as Type THHN, conductor is suitable for use in dry locations at temperatures not to exceed 90° C;
When used as Type THWN-2*, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90° C or not to exceed 75° C when exposed to oil or coolant;

When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60° C or dry locations at temperatures not to exceed 90° C (with ampacity limited to that for 75° C conductor temperature per NFPA 79)

Conductor temperatures not to exceed 105° C in dry locations when rated AWM and used as appliance wiring material. Voltage for all applications is 600 volts

STANDARDS & REFERENCE

THHN or THWN-2* or MTW (also AWM) meets or exceeds all applicable ASTM specifications, UL Standard 83, UL Standard 1063 (MTW), Federal Specification A-A-59544, and requirements of the National Electrical Code.

SPECIFICATION
MTW or THHN or THWN-2

Conductors shall be UL-listed Type MTW or THHN or THWN-2* gasoline and oil resistant II, suitable for operations at 600 volts as specified in the National Electrical Code. Sizes 14 through 1 AWG shall be rated VW-1, larger sizes shall be listed for CT use. Sizes 2 AWG and larger listed and marked sunlight-resistant in black only. Conductors shall be annealed copper, insulated with high-heat and moisture resistant PVC, jacketed with abrasion, moisture, gasoline, and oil resistant nylon or listed equivalent

AWM
Conductors shall be UL-listed Type THHN or THWN-2* or MTW or AWM, suitable for
Operation at 600 volts at conductor temperatures not to exceed 105° C.

Conductor Insulation
Thickness
(mils)
Jacket thickness
(mils)
Nominal O.D Approx. net weight/1000ft Allowable ampacities
Size
(AWG or kcmil)
Strands Solid Stranded Solid Stranded 60 0 C 75 0 C 90 0 C
14 19 15 4 102 109 15 16 15 15 15
12 19 15 4 119 128 23 24 20 20 20
10 19 20 4 150 161 37 38 30 30 30
8 19 30 5 / 213 / 62 40 50 55
6 19 30 5 / 249 / 95 55 65 75
4 19 40 6 / 318 / 152 70 85 95
3 19 40 6 / 346 / 188 85 100 110
2 19 40 6 / 378 / 234 95 115 130
1 19 50 7 / 435 / 299 110 130 150
1/0 19 50 7 / 474 / 371 125 150 170
2/0 19 50 7 / 518 / 461 145 175 195
3/0 19 50 7 / 568 / 574 165 200 225
4/0 19 50 7 / 624 / 717 195 230 260
250 37 60 8 / 694 / 850 215 255 290
300 37 60 8 / 747 / 1011 240 285 320
350 37 60 8 / 797 / 1173 260 310 350
400 37 60 8 / 842 / 1333 280 335 380
500 37 60 8 / 926 / 1653 320 380 430
600 61 70 9 / 1024 / 1985 355 420 475
750 61 70 9 / 1126 / 2462 400 475 535
1000 61 70 9 / 1275 / 3254 455 545 615