Low Voltage1kv Nyy N2xy Copper Cable with CE Certificate
Product Description
Very Competetive Factory price with high quality.
NYY Cable
N2XY Cable
NYY Cable
Low Voltage 06/1kv NYY Cable N2xy Cable , 4 Core cable.
1. Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 70° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed:
Nominal cross section of conductor ≤ 300mm2: 160 ° C
Nominal cross section of conductor >300mm2: 140 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 15 times of the diameter of cable
For multi-core cable: Not less than 12 times of the diameter of cable
When the armored single core cable used for Alternative Current(AC) system, the armoring material should be non-magnetic.
2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical force, but unable to bear large pulling force.
3. Manufacturing Standards
IEC 60502-1 & Chinese national standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.
4.NOTE:
If you want to know more details about this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.
Main technical data of 0.6/1KV, four cores, Copper conductor, PVC insulated and PVC or PE sheath cables
CABLE CONSTRUCTION: 0.6/1KV CU/PVC/PVC or PE
Cable size | Conductor type | Nominal thickness of PVC insulation(mm) |
Nominal thickness of PVC sheath(mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
4×1.5mm2 | RE or RM | 0.8 | 1.8 | 11.0 | 12.1 |
4×2.5mm2 | RE or RM | 0.8 | 1.8 | 11.9 | 7.41 |
4×4mm2 | RE or RM | 1.0 | 1.8 | 14.0 | 4.61 |
4×6mm2 | RE or RM | 1.0 | 1.8 | 15.3 | 3.08 |
4×10mm2 | RM | 1.0 | 1.8 | 18.4 | 1.83 |
4×16mm2 | RM | 1.0 | 1.8 | 20.9 | 1.15 |
4×25mm2 | SM | 1.2 | 1.8 | 21.9 | 0.727 |
4×35mm2 | SM | 1.2 | 1.8 | 24.1 | 0.524 |
4×50mm2 | SM | 1.4 | 1.9 | 27.6 | 0.387 |
4×70mm2 | SM | 1.4 | 2.1 | 31.4 | 0.268 |
4×95mm2 | SM | 1.6 | 2.2 | 36.1 | 0.193 |
4×120mm2 | SM | 1.6 | 2.3 | 39.3 | 0.153 |
4×150mm2 | SM | 1.8 | 2.5 | 43.5 | 0.124 |
4×185mm2 | SM | 2.0 | 2.7 | 48.4 | 0.0991 |
4×240mm2 | SM | 2.2 | 2.9 | 54.6 | 0.0754 |
4×300mm2 | SM | 2.4 | 3.1 | 60.4 | 0.0601 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
CABLE CONSTRUCTION: 0.6/1KV CU/XLPE/PVC or PE
Cable size | Conductor type | Nominal thickness of XLPE insulation(mm) |
Nominal thickness of PVC or PE sheath(mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
4×1.5mm2 | RE or RM | 0.7 | 1.8 | 10.5 | 12.1 |
4×2.5mm2 | RE or RM | 0.7 | 1.8 | 11.5 | 7.41 |
4×4mm2 | RE or RM | 0.7 | 1.8 | 12.6 | 4.61 |
4×6mm2 | RE or RM | 0.7 | 1.8 | 13.8 | 3.08 |
4×10mm2 | RM | 0.7 | 1.8 | 16.9 | 1.83 |
4×16mm2 | RM | 0.7 | 1.8 | 19.5 | 1.15 |
4×25mm2 | SM | 0.9 | 1.8 | 21.3 | 0.727 |
4×35mm2 | SM | 0.9 | 1.8 | 23.4 | 0.524 |
4×50mm2 | SM | 1.0 | 1.9 | 26.8 | 0.387 |
4×70mm2 | SM | 1.1 | 2.0 | 30.6 | 0.268 |
4×95mm2 | SM | 1.1 | 2.1 | 34.9 | 0.193 |
4×120mm2 | SM | 1.2 | 2.3 | 38.4 | 0.153 |
4×150mm2 | SM | 1.4 | 2.4 | 42.5 | 0.124 |
4×185mm2 | SM | 1.6 | 2.6 | 47.4 | 0.0991 |
4×240mm2 | SM | 1.7 | 2.8 | 53.4 | 0.0754 |
4×300mm2 | SM | 1.8 | 3.0 | 59.0 | 0.0601 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
- Next: 4X95mm2 Copper or Aluminum Conductor XLPE/PVC Insulated PVC Sheath Power Cable
- Previous: 3X50+25mm2 Copper Conductor XLPE Insulation PVC Sheath Electric Power Cable