Product Description

Type and Name

Type Name
VV VLV PVC insulated PVC sheathed power cable
VY VLY PVC insulated PE sheathed power cable
VV22 VLV22 PVC insulated, steel tape armored, PVC sheathed power cable
VV23 VLV23 PVC insulated, steel tape armored, PE sheathed power cable
VV32 VLV32 PVC insulated, steel wire armored, PVC sheathed power cable
VV33 VLV33 PVC insulated, steel wire armored, PE sheathed power cable

Construction Sketch

1. Conductor
2. Fire-resistant tape (if there are requirements of fire-resistance)
3. Insulation
4. Filler of fire-resistant material (if there are requirements of fire-resistance)
5. Wrapping tape
6. Inner sheath
7. Armor
8. Outer sheath

Standards
The products can be produced in accordance with GB, IEC, BS, and other standards.

Characteristics and Applications of the Products
PVC insulated PVC sheathed power cable has the advantage of not only good electrical properties and chemical stability, but also simple construction and convenient to use. It applies to the electrical power transmission and distribution lines with A.C.rate voltage U0/U up and including 0.6/1kv.

The main features of the the flame retardant power cable is hard to get fire or that the continuous burning of cables is very limited when it is on fire. It applies to power-generated station, subway, tunnel, high-storey building, large-size factory and mines, oil field and coal mine with many cables laid tightly together.

Fire-resistance cable can operate normally for some time when it is burning except that it can transmit electrical power under normal condition. It is used in the places such as nuclear power station, subway, tunnel, high-storey building and other places concerning to fire security and its life saving.

Application

1. The rated voltage U0/U is 0.6/1kv
2. Maximum conductor temperature under normal operation is 70ºC.
3. Maximum conductor temperature under short circuit (max duration is not more than 5s) is not more than 160ºC.
4. Minimum Installation ambient temperature is not less than 0ºC.
Installation bending radius are not less than the following specified values:

Single core non-armored cable: 20D
Single core armored cable: 15D
3 cores non-armored cable: 15D
3 cores armored cable: 12D
(Note: D-outer diameter of cable)

Main Technical Parameter

FAQ:
1. Are you a trading company or manufacture?
Vango cable is a professional manufacturer in Guangdong, China. Established in 1988, we have 30 years experience in this industry.

2. What is your main product?
As one of leading cable manufacturers in China, we are specialized in power cables with rated voltage up to 35kV, common type, fire-resistance and flame retardant PVC cable with voltage up to 1kV, control cable of 450/750V, PVC insulated cable and wire, AAC, ACSR, ACSR/AS, heat-resistant Aluminum Alloy Conductor and aerial insulated cable up to 35kV, which covers 8 series with more than 3000 items.

3. Can you offer me a free sample?
Yes, sample is free but the freight charge should be borne by you.

4.How is the payment?
T/T, L/C is acceptable.

5. What is the lead time for mass production?
It depends on the order quantity and the season you place the order. Normally within 1 month.

6.Do you accept OEM or ODM?
Yes, we accept OEM and ODM. Your logo and company name can be printed on our products.

7.Do you have after-sale service?
Yes, 12 months warranty.

Our company

Workshop

Customer

Certificates

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.