Nyby Copper PVC Insulation Steel Tape Armored PVC Sheath Cable

Nyby Copper PVC Insulation Steel Tape Armored PVC Sheath Cable

Nyby Copper PVC Insulation Steel Tape Armored PVC Sheath Cable

120MM2

Construction, Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC Cable

PVC

PVC

Round Wire

Bare Copper Wire

ISO, CCC, CE, RoHS

YJV

Jytop

DIN VDE 0276-603

Ce, ISO 9001

Black,Red,Yellow,Blue,Brown,Green

JYTOP

Reel or Drum

3x150mm2 x 70mm2

Zhengzhou, China

8544492100

Product Description

Nyby Copper PVC Insulation Steel Tape Armored PVC Sheath Electric Cable

NYBY Power and signalling cable 0,6/1 kV, PVC insulated and sheathed, with steel tapes armour
Application:
NYBY cable are applied for power distribution in city networks, industrial plants and on the places where mechanical damages are expected. May be laid in the ground, cable ducts and in open air.Construction:
Plain copper conductor, as per DIN VDE 0295 cl.1 or cl.2 solid or stranded type,
PVC core insulation, YI4 as per DIN VDE 0207/4
Colour coded to DIN VDE 0293
In respect to 3 + 1/2 conductors, where by only one conductor is allowed to contain a smaller cross-section and permitted to place as insulated core green – yellow as 1/2 conductor, stranded in layer,
Cores are strained concentrically,
Inner covering PVC or rubber mass,
Armouring of two steel tapes,
PVC outer jacket, black, YM3 as per DIN VDE 0207 part 5,
PVC self-extinguishing, test method B acc. to DIN VDE 0472 part 804 and IEC 332-1,

Technical data:
Temperature range
– flexing -5°C to + 50°C
– stationary -30°C to + 70°C
Working voltage Uo/U 0,6/1KV
Test voltage 4KV
Specific insulation resistance at 70°C min. 1010 Ω x cm
Bending radius min:
– for single core cá. 15 x Ø kabel
– for multi core cá. 12 x Ø kabel

Parameter of nyby cable

Cable size Conductor type Nominal thickness of PVC insulation(mm) Nominal
thickness
of steel tape(mm)
Nominal
thickness
of PVC
sheath
(mm)
Approx. cable
overall diameter (mm)
Max. D.C resistance @ 20 0 C (Ω/km)
Phase
core
Earth
core
Phase
core
Earth
core
Phase
core
Earth
core
3×2.5+1.5mm 2 RE RE 0.8 0.8 0.2 1.8 14.9 7.41 12.1
3×4+2.5mm 2 RE RE 1.0 0.8 0.2 1.8 16.7 4.61 7.41
3×6+4mm 2 RE RE 1.0 1.0 0.2 1.8 18.2 3.08 4.61
3×10+6mm 2 RM RE 1.0 1.0 0.2 1.8 20.8 1.83 3.08
3×16+10mm 2 RM RM 1.0 1.0 0.2 1.8 23.5 1.15 1.83
3×25+16mm 2 SM RM 1.2 1.0 0.2 1.8 24.2 0.727 1.15
3×35+16mm 2 SM RM 1.2 1.0 0.2 1.8 25.9 0.524 1.15
3×50+25mm 2 SM SM 1.4 1.2 0.5 2.0 30.5 0.387 0.727
3×70+35mm 2 SM SM 1.4 1.2 0.5 2.1 33.9 0.268 0.524
3×95+50mm 2 SM SM 1.6 1.4 0.5 2.3 38.5 0.193 0.387
3×120+70mm 2 SM SM 1.6 1.4 0.5 2.4 41.8 0.153 0.268
3×150+70mm 2 SM SM 1.8 1.4 0.5 2.5 45.0 0.124 0.268
3×185+95mm 2 SM SM 2.0 1.6 0.5 2.7 49.9 0.0991 0.193
3×240+120mm 2 SM SM 2.2 1.6 0.5 2.9 55.5 0.0754 0.153
3×300+150mm 2 SM SM 2.4 1.8 0.5 3.1 61.0 0.0601 0.124

Permissible tensile stress with cable grip for Cu- conductor max 50 N/mm2
Note: RE= round conductor RM = stranded conductor SM=sectional conductor