High Quality ABC Overhead Cable

High Quality ABC Overhead Cable

High Quality ABC Overhead Cable

JKLYJ

Insulated

Stranded

Overhead

Aluminum

PVC

PVC

ISO9001, CE

SABS

Henan Jiapu

Aluminum

None

None

0.6/1kv,10kv

1-4 Cores

ASTM, BS, CSA, DIN

jiapu

Wooden Drum or Wooden&Steel Drum

IEC, ASTM, BS, DIN

Henan, China

4101962331

Product Description

1.Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.

2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.

3. Detaild Introduction of Service Drop Cable
3.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.2 Triplex Service Drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.

Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

Construction
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.

Standard:

ASTM B230, B231, B232 and B-399 ,B498,ICEA S-76-474

Code Name

Phase Conductor

Bare Neutral

Approx.Weight

Code Name

Phase Conductor

Bare Neutral

Approx.Weight

Size

Stranding

Insulation Thickness

Size

Stranding

XLPE

PE

Size

Stranding

Insulation Thickness

Size

Stranding

XLPE

PE

AWG

mil

AWG

lbs/1000ft

AWG

mil

AWG

lbs/1000ft

AAC Neutral Messenger

ACSR Neutral Messenger

Pekingese

6

Solid

45

6

7/w

63.5

61.7

Setter

6

Solid

45

6

6/1

75.0

73.2

Collie

6

7/w

45

6

7/w

66.8

63.1

Shepherd

6

7/w

45

6

6/1

78.3

74.6

Dachshund

4

Solid

45

4

7/w

95.5

93.4

Eskimo

4

Solid

45

4

6/1

113.7

111.6

Spaniel

4

7/w

45

4

7/w

100.5

95.4

Terrier

4

7/w

45

4

6/1

118.7

113.6

Doberman

2

7/w

45

2

7/w

152.7

145.7

Chow

2

7/w

45

2

6/1

181.7

174.7

Malemute

1/0

19/w

60

1/0

7/w

242.6

234.2

Bull

1/0

19/w

60

1/0

6/1

288.7

280.3

6201 Alloy Neutral Messenger

Chihuahua

6

Solid

45

6

7/w

67.6

65.8

Whippet

4

7/w

45

4

7/w

107.0

101.9

Vizsla

6

7/w

45

6

7/w

70.9

67.2

Schnauzer

2

7/w

45

2

7/w

163.3

156.2

Harrier

4

Solid

45

4

7/w

102.0

99.9

Heeler

1/0

19/w

60

1/0

7/w

259.2

250.8

Note:

(1)Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

(2)Conductor temperature of 90°C for XLPE, 75°C for PE; ambient temperatures of 40°C; emissivity 0.9; 2ft./sec/wind in sun.