ASTM Standard Stay Wire, Guy Wire Stranded Galvanized Steel Wire
Product Description
Application:
The galvanized single steel wires or stranded steel wires are suitable for cores of ACSR to improve its tensile strength. And they can also be used in the aerial transmission line as the line material of ground connection to avoid the lightning strike.
Construction:
The single wires are concentrically stranded and wrapped helically around a central wire.
Specification:
Partial Specification:
(1) ASTM A 475 Standard
No./Dia. of Wires | Approx. Stranded Dia. | Siemem Martin Grade | High Strength Grade | Extra-high Strength Grade | Approx. Weight | No./Dia. of Wires | Approx. Stranded Dia. | Siemem Martin Grade | High Strength Grade | Extra-high Strength Grade | Approx. Weight |
No./mm | mm | kN | kN | kN | kg/km | No./mm | mm | kN | kN | kN | kg/km |
3/2.64 | 5.56 | 10.409 | 15.569 | 21.796 | 131 | 7/3.05 | 9.52 | 30.915 | 48.04 | 68.503 | 407 |
3/3.05 | 6.35 | 13.523 | 21.04 | 29.981 | 174 | 7/3.68 | 11.11 | 41.591 | 64.499 | 92.523 | 594 |
3/3.05 | 6.35 | – | – | – | 174 | 7/4.19 | 12.7 | 53.823 | 83.627 | 119.657 | 768 |
3/3.30 | 7.14 | 15.035 | 23.398 | 33.362 | 204 | 7/4.78 | 14.29 | 69.837 | 108.981 | 155.688 | 991 |
3/3.68 | 7.94 | 18.193 | 28.246 | 40.479 | 256 | 7/5.26 | 15.88 | 84.961 | 131.667 | 188.605 | 1211 |
3/4.19 | 9.52 | 24.732 | 37.187 | 52.489 | 328 | 19/2.54 | 12.7 | 56.492 | 84.961 | 118.768 | 751 |
7/1.04 | 3.18 | 4.048 | 5.916 | 8.14 | 49 | 19/2.87 | 12.49 | 71.616 | 107.202 | 149.905 | 948 |
7/1.32 | 3.97 | 6.539 | 9.519 | 13.078 | 76 | 19/3.18 | 15.88 | 80.513 | 124.995 | 178.819 | 1184 |
7/1.57 | 4.76 | 8.452 | 12.677 | 17.748 | 108 | 19/3.81 | 19.05 | 116.543 | 181.487 | 259.331 | 1719 |
7/1.65 | 4.76 | – | – | – | 118 | 19/4.50 | 22.22 | 159.691 | 248.211 | 354.523 | 2352 |
7/1.83 | 5.56 | 11.387 | 17.126 | 24.02 | 145 | 19/5.08 | 25.4 | 209.066 | 325.61 | 464.839 | 2384 |
7/2.03 | 6.35 | 14.012 | 21.129 | 29.581 | 181 | 37/3.63 | 25.4 | 205.508 | 319.827 | 456.832 | 3061 |
7/2.36 | 7.14 | 18.905 | 28.469 | 39.812 | 243 | 37/4.09 | 28.58 | 262 | 407.457 | 581.827 | 4006 |
7/2.64 | 7.94 | 23.798 | 35.586 | 49.82 | 305 | 37/4.55 | 31.75 | 324.72 | 505.318 | 721.502 | 4833 |
(2) BS 183 Standard
No./Dia. of Wires | Approx. Stranded Dia. | Minimum Break Load of Stranding Wires | Approx Weight | No./Dia. of Wires | Approx. Stranded Dia. | Minimum Break Load of Stranding Wires | Approx. Weight | ||||||||||||
Grade 350 | Grade 480 | Grade 700 | Grade 850 | Grade 1000 | Grade 1150 | Grade 1300 | Grade 350 | Grade 480 | Grade 700 | Grade 850 | Grade 1000 | Grade 1150 | Grade 1300 | ||||||
No./mm | mm | kN | kN | kN | kN | kN | kN | kN | kg/km | No./mm | mm | kN | kN | kN | kN | kN | kN | kN | kg/km |
3/1.80 | 3.9 | 2.65 | 3.66 | – | – | – | – | – | 60 | 7/2.00 | 6.0 | 7.70 | 10.55 | 15.40 | – | 22.00 | 25.30 | 28.60 | 170 |
3/2.65 | 5.7 | 5.80 | 7.95 | – | – | – | – | – | 130 | 7/2.36 | 7.1 | 10.70 | 14.70 | 21.40 | – | 30.60 | 35.20 | 39.80 | 240 |
3/3.25 | 7.0 | 8.70 | 11.95 | – | – | – | – | – | 195 | 7/2.65 | 8.0 | 13.50 | 18.50 | 27.00 | – | 38.60 | 44.40 | 50.20 | 300 |
3/4.00 | 8.6 | 13.20 | 18.10 | – | – | – | – | – | 295 | 7/3.00 | 9.0 | 17.30 | 23.75 | 34.65 | – | 49.50 | 56.90 | 64.30 | 392 |
4/1.80 | 4.4 | 3.55 | 4.90 | – | – | – | – | – | 80 | 7/3.15 | 9.5 | 19.10 | 26.20 | 38.20 | – | 54.55 | 62.75 | 70.90 | 430 |
4/2.65 | 6.4 | 7.70 | 10.60 | – | – | – | – | – | 172 | 7/3.25 | 9.8 | 20.30 | 27.85 | 40.65 | – | 58.05 | 66.80 | 75.50 | 460 |
4/3.25 | 7.9 | 11.60 | 15.90 | – | – | – | – | – | 260 | 7/3.65 | 11.0 | 25.60 | 35.15 | 51.25 | – | 73.25 | 84.20 | 95.20 | 570 |
4/4.00 | 9.7 | 17.60 | 24.10 | 35.20 | – | – | – | – | 390 | 7/4.00 | 12.0 | 30.90 | 42.20 | 61.60 | – | 88.00 | 101.0 | 114.0 | 690 |
5/1.50 | 4.1 | 3.10 | 4.24 | 6.18 | – | – | – | – | 69 | 7/4.25 | 12.8 | 34.75 | 47.65 | 69.50 | – | 99.30 | 114.0 | 129.0 | 780 |
5/1.80 | 4.9 | 4.45 | 6.10 | 8.90 | – | – | – | – | 95 | 7/4.75 | 14.0 | 43.40 | 59.45 | 86.80 | – | 124.0 | 142.7 | 161.3 | 970 |
5/2.65 | 7.2 | 9.65 | 13.25 | 19.30 | – | – | – | – | 220 | 19/1.0 | 5.0 | 5.22 | 7.16 | 10.45 | – | 14.92 | 17.16 | 19.40 | 120 |
5/3.25 | 8.8 | 14.50 | 19.90 | 29.00 | – | – | – | – | 320 | 19/1.25 | 6.3 | 8.16 | 11.19 | 16.32 | – | 23.32 | 26.81 | 30.31 | 180 |
5/4.00 | 10.8 | 22.00 | 30.15 | 43.95 | – | – | – | – | 490 | 19/1.40 | 7.0 | 10.24 | 14.04 | 20.47 | – | 29.25 | 33.64 | 38.02 | 230 |
7/0.56 | 1.7 | 0.60 | 0.83 | 1.20 | – | 1.70 | 1.98 | 2.24 | 14 | 19/1.6 | 8.0 | 13.37 | 18.35 | 26.75 | – | 38.20 | 43.93 | 49.66 | 300 |
7/0.71 | 2.1 | 0.97 | 1.33 | 1.94 | – | 2.75 | 3.19 | 3.60 | 28 | 19/2.0 | 10.0 | 20.90 | 28.65 | 41.78 | 50.74 | 59.69 | 68.64 | 77.60 | 470 |
7/0.85 | 2.6 | 1.39 | 1.90 | 2.80 | – | 3.95 | 4.57 | 5.15 | 31 | 19/2.5 | 12.5 | 32.65 | 44.80 | 65.29 | 79.28 | 93.27 | 107.3 | 121.3 | 730 |
7/0.90 | 2.7 | 1.55 | 2.14 | 3.10 | – | 4.45 | 5.12 | 5.80 | 35 | 19/3.0 | 15.0 | 47.00 | 64.50 | 94.00 | 114.1 | 134.3 | 154.5 | 174.6 | 1050 |
7/1.00 | 3.0 | 1.92 | 2.64 | 3.85 | – | 5.50 | 6.32 | 7.15 | 43 | 19/3.55 | 17.8 | 65.80 | 90.27 | 131.6 | 159.9 | 188.0 | 216.3 | 244.5 | 1470 |
7/1.25 | 3.8 | 3.01 | 4.10 | 6.00 | – | 8.55 | 9.88 | 11.15 | 67 | 19/4.0 | 20.0 | 83.55 | 114.6 | 167.1 | 203.0 | 238.7 | 274.6 | 310.4 | 1870 |
7/1.40 | 4.2 | 3.75 | 5.17 | 7.54 | 9.16 | 10.75 | 12.35 | 14.00 | 84 | 19/4.75 | 23.8 | 117.85 | 161.6 | 235.7 | 286.0 | 336.7 | 387.2 | 437.7 | 2630 |
7RS* | 4.3 | 3.85 | 5.28 | 7.70 | 9.35 | 11.00 | 12.65 | 14.30 | 86 | ||||||||||
7/1.60 | 4.8 | 4.90 | 6.75 | 9.85 | 11.95 | 14.10 | 16.20 | 18.30 | 110 | ||||||||||
7/1.80 | 5.4 | 6.23 | 8.55 | 12.45 | – | 17.80 | 20.50 | 23.20 | 140 |
Also have galvanized steel wire ropes(1*7, 7*7, 1*19, and so on)
CABLE WORKSHOP
CABLE QC&QA
CABLE LOADING
CABLE CUSTOMER VISIT
CABLE CERTIFICATE
- Next: High Quality Control Cable
- Previous: Medium Voltage 33kv XLPE Insulated Unarmoured Power Cable
Contact us
Similar Or Related
-
0.6/1kv 800 Series 2*8AWG Aluminum Alloy Conductor XLPE Insulation Concentric Cable
-
0.6/1 Kv Al/XLPE 3*150+150mm ABC Cable Quadruplex Overhead Cable
-
0.6/1 Kv Al/XLPE 2*50+50mm2 Service Drop ABC Cable Triplex Cable
-
Aluminum XLPE 2X25+25 (Bare) mm Overhead Triplex Cable ABC Cable
-
DIN Standard Aluminum Alloy Wire Stranded 1000mm AAAC Conductor
-
ASTM Standard Stay Wire, Guy Wire Stranded Galvanized Steel Wire