1. Standard of ACSR
ACSR conductor can comply with IEC61089, ASTM B232, BS215, GB, DIN etc.

2. Construction of ACSR Conductor:
According to IEC61089, cross section area of ACSR is from 16mm2 to 1250mm2, No of stranded aluminum wire and steel wire can be from Al6/1.84(mm)/Sr1/1.84 to Al84/4.35/Sr19/2.61.

3. Application & Characters of ACSR:
Simple construction, convenient installation, easy maintenance, lower cost, larger transmission capacity, it is applicable to special geographic condition such as river, valley , mountain etc.
Antiseptic ACSR has good antiseptic feature, it is applied to coast area, salt sand area for ultra-high voltage, distribution transmission line. Antiseptic ACSR can be customize to put antiseptic materials among layers as customer’s expected.

BS215.2-1970 ACSR

Nominal Cross-section of Aluminum Nominal Cross-section Code Steel rate Structure O.D. Max. DC resistane of conductor at 20ºC Breaking load Weight of material Approx. weight of conductor
Aluminum Steel
Aluminum / Steel Number of wires / Diameter Number of wires / Diameter Steel core Conductor Aluminum Galvanized steel wire
mm2 mm2 / mm2 % n / mm n / mm mm mm Ω/km kN kg/km kg/km kg/km
25 25 / 4 GOPHER 16% 6 / 2.36 1 / 2.36 2.36 7.08 1.093 9.61 71.9 34.0 105.9
30 30 / 5 WEASEL 17% 6 / 2.59 1 / 2.59 2.59 7.77 0.9077 11.45 86.6 41.0 127.5
40 40 / 7 FERRET 18% 6 / 3.00 1 / 3.00 3.00 9.00 0.6766 15.20 116.1 55.0 171.1
50 50 / 9 RABBIT 18% 6 / 3.35 1 / 3.35 3.35 10.05 0.5426 18.35 144.8 68.6 213.4
70 70 / 43 HORSE 61% 12 / 2.79 7 / 2.79 8.37 13.95 0.3936 61.20 202.7 334.6 537.3
100 100 / 14 DOG 14% 6 / 4.72 7 / 1.57 4.71 14.15 0.2733 32.70 288.6 106.0 394.6
150 150 / 37 WOLF 25% 30 / 2.59 7 / 2.59 7.77 18.13 0.1828 69.20 436.6 288.4 725.0
150 150 / 9 DINGO 6% 18 / 3.35 1 / 3.35 3.35 16.75 0.1815 35.70 437.0 68.6 505.6
175 175 / 43 LYNX 25% 30 / 2.79 7 / 2.79 2.79 19.53 0.1576 79.80 506.7 334.6 841.3
175 175 / 10 CARACAL 6% 18 / 3.61 1 / 3.61 3.61 18.05 0.1563 41.1 507.5 79.6 587.1
200 200 / 49 PANTHER 25% 30 / 3.00 7 / 3.00 3.00 21.00 0.1363 92.25 585.8 386.9 972.7
200 200 / 12 JAGUAR 6% 18 / 3.86 1 / 3.86 3.86 19.30 0.1367 46.55 580.2 91.0 671.2
400 400 / 56 ZEBRA 14% 54 / 3.18 7 / 3.18 3.18 28.62 0.0674 131.9 1185.9 434.7 1620.6

Main feature
Type: Bare
Conductor Type: Stranded
Application: Overhead Transmission Line
Conductor Material: Aluminum
Sheath Material: Bare
Insulation Material: Bare
Basic Information
Model No: ACSR Conductor
Material Shape: Round Wire
Range of Application: Overhead Installation Certificate: ISO9001,ISO14001, CCC, CE
Brand Name: GDYG
HS Code: 7614100000
ACSR Code: Turkey, Swan, etc ACSR Feature: Simple Construction, Easy Installation, Excellent Electric and Mechanical and Conductive etc
Specification: 10mm2 – 1500mm2 ACSR Conductor Advantage: Antiseptic Model.
Supply Record: African countries, Arabian countries, Asian countries etc.