1KV PVC Insulated Power Cable
1. Application
Suitable for rated AC voltage 0.6/1 KV and below electric distribution lines without flame-retardant or fire-resistant requirements.
The flame-retardant type cables are not easy to burn or their flame propagation is limited only in a certain length. These cable are suitable for high installation density places like power station, subway, tunnel, high-building, large industrial enterprise, oil field and mine etc.
The fire-resistant cables can not only operate in normal condition, but also can operate in fire during a certain time. These cables are suitable for power station, subway, high building and other high human density places where haveing fire-proof and fire-fight requirements.

2. Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 70° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed:
Nominal cross section of conductor ≤ 300mm2: 160° C;
Nominal cross section of conductor >300mm2: 140° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For multi-core cable: Not less than 15 times of the diameter of cable

3. Manufacturing Standards
IEC 60502-1 & Chinese national standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.

KINDLY NOTE:
FOR further detailed information about this kind of product, please browse our website: jytopcable. Thanks.

Tips: RE= round conductor RM = stranded conductor SM=sectional conductor

Cable size Conductor type Nominal thickness of PVC insulation(mm) Nominal thickness of PVC sheath(mm) Approx. cable overall diameter (mm) Max. D.C resistance @ 20 0 C (Ω/km)
4×1.5mm 2 RE or RM 0.8 1.8 11.0 12.1
4×2.5mm 2 RE or RM 0.8 1.8 11.9 7.41
4x4mm 2 RE or RM 1.0 1.8 14.0 4.61
4x6mm 2 RE or RM 1.0 1.8 15.3 3.08
4x10mm 2 RM 1.0 1.8 18.4 1.83
4x16mm 2 RM 1.0 1.8 20.9 1.15
4x25mm 2 SM 1.2 1.8 21.9 0.727
4x35mm 2 SM 1.2 1.8 24.1 0.524
4x50mm 2 SM 1.4 1.9 27.6 0.387
4x70mm 2 SM 1.4 2.1 31.4 0.268
4x95mm 2 SM 1.6 2.2 36.1 0.193
4x120mm 2 SM 1.6 2.3 39.3 0.153
4x150mm 2 SM 1.8 2.5 43.5 0.124
4x185mm 2 SM 2.0 2.7 48.4 0.0991
4x240mm 2 SM 2.2 2.9 54.6 0.0754
4x300mm 2 SM 2.4 3.1 60.4 0.0601