300V 500V 450V 750V Thhn Thwn House Building Wiring Fire Retardant Nylon PE XLPE PVC Insulated Flexible Copper Electrical Cable Electric Wire

300V 500V 450V 750V Thhn Thwn House Building Wiring Fire Retardant Nylon PE XLPE PVC Insulated Flexible Copper Electrical Cable Electric Wire

Quick Details

300V 500V 450V 750V Thhn Thwn House Building Wiring Fire Retardant Nylon PE XLPE PVC Insulated Flexible Copper Electrical Cable Electric Wire

Electric Cable

Rmjt

ISO9001, CE, UL, CCC, RoHS

Flame Retardant

Round Wire

PVC

PVC

Copper

Overhead, Heating, Underground

Stranded

Insulated

Copper Conductor Tw Thw Building House Wire

Manufacturer

GB 5023.1~7-1997 IEC 60227

ISO9001-2008, ISO14001-2004, CCC, SGS, BV etc

BV, Blv, BVV, Blvv, BVVB, Blvvb, RV, Rvb, Rvs, Rvv

300/300V, 450/750V

Single, 2, 3 or 4 Cores

Packing in Rolls or as Your Requirement

Professional Manufacturer of 25 Years in China

High Quality, Competitive Price, Fast Delivery

RMJT

Package in Rolls or as Your Request

0.5mm2-400mm2

Henan, China

8544492100

Product Details


Copper Conductor Tw Thw Building House Wire

Product Construction
1.Conductor: bare/tinned copper,or Aluminum. Stranded uncoated copper conductors per ASTM-B3, ASTM-B787, and ASTM-B8
2.Insulation: PVC rated at 70°C. Color-coded Polyvinyl Chloride (PVC) heat and moisture resistant, flame-retardant compound per UL 1063 and UL 83
3.Color Code: red,orange,yellow,yellow-green,blue,purple,gray,white or as your requirement
4.Outer sheath: PVC tapes ST2 to IEC. Nylon, THHN tough, polyamide, Nylon outer covering per UL 1063 and UL 83 Slick Nylon outer jacket for easy pulling.
5. Conductor Type: Stranded conductor or solid conductor

Service Performance Of Copper Wire
1. Rated voltage: 300/300V ; 300/500V ;450/750V
2. Long-term working temperature: not be higher than 70°C
3. When laying the cable, the ambient temperature should not lower than 0°C
4. Working Temperature: At the rated drying temperature is 90 degrees Celsius, at a nominal temperature of 75 ° C wet, rated THWN. Most THHN building wire in the wet and dry temperature ratings are marked with THHN / THWN double rating. 
When used as Type THHN conductor suitable for oil or cooling liquid temperature did not exceed wet or dry place at 90 ° C or 75 ° C to. When used as an MTW type, for conductors of 90 ° C in a dry place, moist places or places exposed to oil or coolant is not above 60 ° C is used.
5. Minimum bending radius: Bending radius ≥ 4D as cable overall diameter ≤ 25mm; Bending radius ≥ 6D ascable overall diameter > 25mm.
6. Building Applications THHN Wire: THHN Wire representative of a high heat thermoplastic nylon coating. Machine for the control circuit wiring or some device. It is suitable for the new configuration of rewiring or 600 volts applied, and suitable for general use in the National Electrical Code (NEC) defined.

TW THW

TW THW 600V 60ºC
UL 83 UL 1581
Type TW and THW may be used for general purpose wiring for power and lighting, for insulation in air, conduit, duct or other recognized raceways, in wet or dry locations. Maximum voltage rating= 600 V
MAXIMUM CONDUCTOR TEMPERATURE
type oil wet dry
TW 60ºC 60ºC 60ºC
THW 75ºC 75ºC 75ºC
MTW* 60ºC 60ºC 90ºC
* 1AWG AND LARGER ONLY  
AWG /
MCM
mm2 Conductor Conductor Insulation Total
Weight
 kg/km
Single Wire OD. PVC
Type No. Dia. Thick mm Thick min OD.
mils
18 0.82 solid 1 1.02 1.02 30 0.76 0.89 0.7 2.54 14.82
16 1.31 solid 1 1.29 1.29 30 0.76 0.89 0.7 2.81 20.27
14 2.09 solid 1 1.63 1.63 30 0.76 0.89 0.7 3.15 28.6
12 3.33 solid 1 2.06 2.06 30 0.76 0.89 0.7 3.58 41.48
10 5.27 solid 1 2.59 2.59 30 0.76 0.89 0.7 4.11 60.93
8 8.35 solid 1 3.26 3.26 45 1.14 1.22 1 5.54 98.99
6 13.33 solid 1 4.12 4.12 60 1.52 1.67 1.4 7.16 162.23
4 21.16 solid 1 5.19 5.19 60 1.52 1.67 1.4 8.23 240.34
18 0.82 B 7 0.386 1.158 30 0.76 0.89 0.7 2.678 15.65
16 1.31 B 7 0.488 1.464 30 0.76 0.89 0.7 2.984 21.43
14 2.08 B 7 0.615 1.845 30 0.76 0.89 0.7 3.365 30.1
12 3.30 B 7 0.775 2.325 30 0.76 0.89 0.7 3.845 43.38
10 5.26 B 7 0.978 2.934 30 0.76 0.89 0.7 4.454 64.02
8 8.32 B 7 1.23 3.69 45 1.14 1.22 1 5.97 103.92
6 13.21 B 7 1.55 4.65 60 1.52 1.67 1.4 7.69 169.62
4 21.12 B 7 1.96 5.88 60 1.52 1.67 1.4 8.92 252.44
2 33.54 B 7 2.47 7.41 60 1.52 1.67 1.4 10.45 379.53
1 42.62 B 19 1.69 8.18 80 2.03 2.11 1.8 12.24 480.75
1/0 53.30 B 19 1.89 9.19 80 2.03 2.11 1.8 13.25 586.71
2/0 67.70 B 19 2.13 10.34 80 2.03 2.11 1.8 14.4 727.52
3/0 85.24 B 19 2.39 11.61 80 2.03 2.11 1.8 15.67 897.84
4/0 107.18 B 19 2.68 13 80 1.52 1.67 1.4 16.44 1097.15
250 126.94 B 37 2.09 14.2 95 2.41 2.56 2.2 19.02 1340.08
300 152.39 B 37 2.29 15.54 95 2.41 2.56 2.2 20.36 1586.07
350 177.29 B 37 2.47 16.79 95 2.41 2.56 2.2 21.61 1825.98
400 202.53 B 37 2.64 17.96 95 2.41 2.56 2.2 22.78 2068.12
500 252.89 B 37 2.95 20.04 95 2.41 2.56 2.2 24.86 2548.31
600 304.24 B 61 2.52 22 110 2.79 2.89 2.5 27.58 3084.92
750 380.99 B 61 2.82 24.64 110 2.79 2.89 2.5 30.22 3816.9
1000 506.04 B 61 3.25 28.4 110 2.79 2.89 2.5 33.98 5002.6
 
We could produce most of the standards cables, such as ASTM, BS, CSA, DIN, GB and IEC Standards, etc.
ISO9001:2008, OHSAS, CCC, TUV Certifications.
 Packing and Delivery:
 

 
Production Line:
 
Our Company:

People’s Cable Group Co., Ltd, a professional wires and cables manufacturer for 27 years in China. we mainly produce power cables, control cables, aerial overhead cables(ABC, AAC ACSR and AAAC cables) etc. Standards Supported: ASTM, BS, CSA, IEC, DIN and GB etc.
1. Factory: 160000 square meters, available for OEM;
2. Lead time: 5-7 working days after payment received;
3. Authentication: TUV, OHSAS, CCC,  ISO9001:2008;
4. Guarantee: 20 years;
5. QC inspection: Strict inspection before delivery;
After-sales Service:
1. All our cables will be tested well in production and before delivery.
2. Please contact us if any problem, we will respond within 24 hours.

FAQ:

Q: Do you accept customize?
A: Yes, we have our own factory, all communication cables are customized. 
Q: Can you print our logo or company name? 
A: Yes, we could print your logo or company name on our products.
Q: Can you design for us? 
A: Yes, we have professional designer, please tell us your requirement, let us do it for you. 
Q: Is it possible to get a free sample?
A: Yes, stock samples are free, but shipping cost you collect. We could also customize sample for you,the specific price will be confirmed according to the sample’s workmanship.If we have a further cooperation in the future, the sample fee will be returned. 
Q: What is your MOQ?
A: Usually, MOQ of communication cable is 1,000 meter, MOQ of rf connector is 500 pcs. But depend on the different material, size and workmanship, the MOQ will be changed. 
Q: How long can we receive your quotation? 
A: If your information is very detail, quotation will be offered within 6 hours. In order to receive our quotation as soon as possible, please give us following information: 
1) Type; 2) Size; 3) Specification; 4) Quantity. 
If it is possible, please also provide with pictures or design for checking. Sample will be best for clarifying. 
Q: Do you have a range of stock items for sale? 
A: We have enough neutral storage for hot-selling items. 
Q: What is your delivery time?
A: Usually 7-10 days. According to the product and quantity, delivery time will have different.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.