XLPE or PE ABC Cable Duplex Drop 16mm2 AAC+AAAC

XLPE or PE ABC Cable Duplex Drop 16mm2 AAC+AAAC

XLPE or PE ABC Cable Duplex Drop 16mm2 AAC+AAAC

Insulated

Stranded

Overhead

Aluminum

XLPE or PE

ISO9001, CE, CCC

0.6/1 Kv, 11kv, 33kv

Duplex, Triplex, Quadruplex

AAC

AAC, AAAC, ACSR

Jinshui

Export Wooden Drum, Iron-Wooden Drum, Soft Roll

ISO, CE, CCC

Zhengzhou Henan

Product Description

Specifications

Standard: National Standard IEC and ASTM

Rated Voltage: 0.6/1KV, 11KV, 33KV

Construction: Phase conductor: aluminum stranded(AAC)

                        Neutral conductor: aluminum stranded(AAC), aluminum alloy stranded(AAAC), aluminum conductor steel reinforced(ACSR)

                       Insulation: XLPE or PE

Application:  The cables are designed for aerial power lines and room-entrance wires with voltage up to and including 0.6/1KV.

Uesd for overhead service application such as street linghting, outdoor lighting and temporary service for cunstruction.which improves the safety and reliance of electrified wire netting.

 

1 Type:Duplex Service Drop, Triplex Service Drop, Quadruplex Service Drop

 

   a Duplex Service Drop

  Applications:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.

 

  b Triplex Service Drop

  Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .

 

  c Quadruplex Service Drop

  Applications: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

 

 

2  Construction
    Phase Conductor construction:The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.

 

   b  Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:

Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded

Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded

Aluminum alloy 6201-T81, concentric-lay-stranded

 

  c Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)

Alternatively, black linear low-density polyethylene (LDPE) insulation with a 75°C temperature rating is available upon request.
 

 