XLPE Insulation Al/R ABC Cable 2X16mm2 4X16mm2 Aerial Power Cable

XLPE Insulation Al/R ABC Cable 2X16mm2 4X16mm2 Aerial Power Cable

XLPE Insulation Al/R ABC Cable 2X16mm2 4X16mm2 Aerial Power Cable

Aerial Power Cable

Hongda

ISO9001, CCC, SGS

Aerial Power

Round Wire

XLPE

Al/R Cable

Aluminum

Overhead

Stranded

Insulated

600/1000V

AAC / XLPE or PE

OEM, ODM

Hongda, or OEM

1000m Per Drum, 5000m Per Drum

4x16mm abc cable, 2x16mm abc cable

China

8544492100

Product Description

XLPE insulation AL/R ABC Cable 2x16mm2 4x16mm2 Aerial Power Cable

Application

The power cables with cross-linked polyethylene (XLPE) insulation for overhead lines are designed for electrical installations with alternating power networks with nominal voltage Uo/U 0.6/1 kV or in direct power networks with maximum voltage according to land 0.9 кV. The cables with supporting (bearing) zero conductors are used for building networks in city and urban areas and the self-supporting type cables are for building distribution networks in these areas.

The cables with supporting (bearing) zero conductors are used for building networks in city and urban areas and the self-supporting type cables are for building distribution networks in these areas.
Cables for overhead installations may be used in different types of installations: on free hanging facades; between posts; on fixed facades; trees and poles. Interception of forest areas without the need of clearance and maintenance of openings is allowed.
 
-Cables with supporting zero conductor, the whole bundle is suspended and carried by the supporting conductor, which is made of aluminum compound.
– Self-supporting construction, suspension and carrying of the whole bundle is done by the phase insulated conduc­tors. Bundles can include one or two additional conductors for public lighting and control pair.

STANDARDS
IEC60502, NFC 33 209, AS/NZS 3560.1.

Cable construction
Construction According to NF C 33-209
Conductor
phase(main) M
Al stranded compacted or
Non-compacted according to NF C 33-209
– neutral (supporting) N AL stranded according to NF C 33-209
-additional for lighting   R Al stranded compacted or non-compacted according to NF C 33-209
Insulation XLPE with min. 2% carbon black content
Constructions twisted into a bundle include:
– phase (main) insulated cores(M)
– neutral supporting insulated core  ( N )
– one, two, or three additional reduced insulated cores for lighting ( R )
Color black
Marking: raised with paint:
  – phase – with numbers 1;2;3
  – supporting 0 core( N )
  HENAN HONGDA CABLE   NF C 33-209
  additional cores for lighting ( R ) – EP1 and EP2
Technical data
Conductor resistance at 20°C According to NF C 33-209
Operating temperature 90ºC – continuous operation
Overload temperature 130ºC – /100h/per year max./
Short circuit temperature 250ºC  /5 s max./
Nominal voltage AC
                             DC
Uo/U 0.6/1 kV
0.9 kV
Highest system voltage
AC, not more than
1.2 kV
Test voltage:
 
AC -15 min
DC – 15 min
4 kV
10 kV
between cores – 3.5 kV
between core and armor – 3.5 kV
Bending radius, min. Temperature of laying – 18x D cable
no less than – 10ºC –
recommended 15°C
Resistance at 20°C: 16 -1.91 Ω/km
70-0.443 Ω/km 
25 -1.20 Ω/km
95-0.320 Ω/km
 
 
 
35 – 0.868 Ω/km
120-0.253 Ω/km
50 – 0.641 Ω/km
150-0.206 Ω/km
54.6Alm-0.63 Ω/km;
70Alm -.5 Ω/km
 
Supported neutral breaking strength min
 
95Alm – 0.343 Ω/km
54.6 – 16 kN
70 – 20.50 kN
95 – 27.50 kN

Al Aerial Bundled cables (ABC)

Construction data  Al/R 0.6/1 kV
Number of conductors
and nominal cross
section
Thickness of insu­lation M/N/R Diameter
of bundle
approx.
Allowed cur­rent in power supply net­works Allowed current in distribution net­works Al/R
Mass of Al core approx. Cable weight approx.
LlE mm mm   A kg/km kg/km
        walls/air/facades    
2×16 1.2 15 72 / 93 / 83 91 125
2×25 1.4 18 95 / 122 / 111 142 165
4×16 1.2 18 63 / 83 / 75 183 260
4×25 1.4 22 83 / 111 / 99 285 395
3×25+54.6Alm 1.4/1.6 30 112 369 505
3×25+54.6Alm+Kx16 1.4/1.6/1.2 30 112 / 83 460 635
3×35+54.6Alm 1.6/1.6 33 138 455 615
3×35+54.6Alm+Kx16 1.6/1.6/1.4 33 138 / 83 546 745
3×50+54.6Alm 1.6/1.6 36 168 583 725
3×50+54.6Alm+Kx16 1.6/1.6/1.2 36 168 / 93 674 860
3×50+54.6Alm+Kx25 1.6/1.6/1.4 36 168 / 111 725 925
             
3×70+54.6Alm 1.8/1.6 37 213 754 950
3×70+54.6Alm+Kx16 1.8/1.6/1.2 40 213 / 83 845 1080
3×70+54.6Alm+Kx25 1.8/1.6/1.4 40 213 / 111 896 1150
3×70+70Alm 1.8/1.5 41 213 798 984
3×70+70Alm+Kx16 1.8/1.5/1.2 41 213 / 83 889 1115
3×70+70Alm+Kx25 1.8/1.5/1.4 41 213 / 111 940 1185
             
3×95+54.6Alm 1.8/1.6/ 44 258 967 1195
3×95+54.6Alm+Kx16 1.8/1.6/1.2 44 258 / 83 1059 1325
3×95+54.6Alm+Kx25 1.8/1.6/1.4 44 258 / 111 1110 1355
3×95+70Alm 1.8/1.5 44 258 1011 1355
3×95+70Alm+Kx16 1.8/1.5/1.2 44 258 / 83 1102 1615
3×95+70Alm+Kx25 1.8/1.5/1.4 44 258 / 111 1154 1485
3×120+70Alm 1.8/1.5 46 300 1225 1445
3×120+70Alm+KxT6 1.8/1.5/1.2 46 300 / 83 4828 1575
3×120+70Alm+Kx25 1.8/1.5/1.4 46 300 /111 1368 1610
3×120+95Alm 1.8/1.6 47 300 1296 1535
SxT20+95Alm+KxTb 1.8/1.6/1.2 47 300 / 83 1387 1660
3×120+95Alm+Kx25 1.8/1.6/1.4 47 300 / 111 1439 1735
3×150+70Alm 1.7/1.5/ 48 344 1482 1670
3×150+70Alm+Kx16 1.7/1.5/1.2 48 344 / 83 1573 1795
3×150+70Alm+Kx25 1.7/1.5/1.4 48 344 / 111 1624 1870

This data was prepared for informational purposes only and does not contain any representations, legally binding declarations or guarantees. Contractual obligations shall only come into effect after a written contract, detailing the terms and conditions, has been signed. A liability of Hongda cables for the correctness of the information contained herein is excluded. The data shall not be handed out to third parties or disclosed in public documents. Any intellectual property rights remain with Hongda cables and are reserved.