XLPE Insulated PVC Sheathed 3 Core Power Cable

XLPE Insulated PVC Sheathed 3 Core Power Cable

XLPE Insulated PVC Sheathed 3 Core Power Cable

3 core power cable

Construction, Overhead, Underground, Industrial, Power Station, Telecommunication

Low and Medium Voltage Cable

AC Cable

XLPE

PVC

Round Wire

Bare Copper Wire

ISO, CCC, RoHS

Yjv32 Yjv22

Rmjt

Armoured or Unarmoured

Manufacturer

1,2,3,4,5, 2+1,3+2

RMJT

Wooden/Steel Drum

1.5mm2-800mm2

Henan, China

8544492100

Product Description
 1.Application
1)XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulate cables.

2)XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level.
3) It can be applied in high temperature of 90 degree for a long time.
4)Flame-retardant and non-flame-retardant XLPE cables can be manufactured by three kinds of technological processes: peroxidation, silanization and irradiation.
5)The flame-retardant cable covers three classes of A, B, C and low-smoke low-halogen, low-smoke non-halogen cables.

1.    Standards: GB/T12706-2008, IEC60502-2005.
2.    Description: copper conductor, XLPE insulated PVC sheathed steel tape armoured power cable.
3.    Conductor: Copper.
4.    Insulation/sheath:XLPE/ PVC
5.    Voltage:0.6/1KV
6.    Type ,description and  application

Type Description   Application
 
 
YJV(YJY)
YJLV(YJLY)
 
 
Copper (Aluminum) conductor , XLPE insulated PVC sheathed power cable.
 
 
For laying indoors, in tunnels, in ducts. Able to bear external mechanical force but not lager pulling forces. Single core cables are impermissible to be laid in magnetic ducts.
 
 
YJV22(YJY22)
YJLV22(YJLY22)
 
 
Copper (Aluminum) conductor , XLPE insulated PVC sheathed steel tape armoured power cable.
 
 
For laying indoors, in tunnels, in ducts and underground. Able to bear external mechanical force but not lager pulling forces. Impermissible to use single core cable in A.C circuit.
 
Type
 
 
NO. of cores
Rated Voltage (kV)
3.6/6 6/6
6/10
8.7/10
8.7/15
12/20 18/20
18/30
21/35 26/35
Nominal cross -section of conductor
YJV
YJLV
YJY
YJLY
1 25-800 25-800 25-800 35-800 50-630 50-630 50-630
3 25-630 25-630 25-500 35-500 50-400 50-400 50-400
YJV22
YJLV22
YJY23
YJLY23
1 25-800 25-800 25-800 35-800 50-630 50-630 50-630
3 25-630 25-630 25-500 35-500 50-400 50-400 50-400
YJV32
YJLV32
YJY33
YJLY33
1 25-800 25-800 25-800 35-800 50-630 50-630 50-630
3 25-630 25-630 25-400 35-400 50-240 50-185 50-150

 
 

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.