XLPE Insulated Aerial Bundled Cables 6.35/11, 12.7/22, 19/33kv Thermocouple ABC Cable Wires

XLPE Insulated Aerial Bundled Cables 6.35/11, 12.7/22, 19/33kv Thermocouple ABC Cable Wires

XLPE Insulated Aerial Bundled Cables 6.35/11, 12.7/22, 19/33kv Thermocouple ABC Cable Wires

ABC CABLE OVERHEAD CABLE

Insulated

Stranded

Overhead

Aluminum

PVC

XLPE

Round Wire

Overhead

ISO9001, CE, CCC

Jinshui

JINSHUI CABLE

Standard export wooden Reel Export Wooden Drums.

CE, SGS, ISO

ZHENGZHOU HENAN

Product Description

0.6/1KV Aerial Bundled Cable ABC Cable

Applications
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross linked polyethylene (XLPE) insulated conductors.

Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP cross linked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.

Standards
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum conductors, Concentric-Lay-Stranded. B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

Note :
Designated sizes are : ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB-399 for
6201.Conductor temperature of 90°C for XLR 75°C for Poly; ambient temperatures of 40°C; emissivity 0.9;
2ft./sec/wind in sun. To determine current ampacity by conductor size, please consult The National Electric
Code, latest edition.

Code Name

Phase Conductor

Bare Neutral Messenger

Weight Per 1000ft (lbs)

Ampacity(amps)

Size AWG

Stranding

Insulation Thickness(mls)

Size AWG

Stranding

Breaking Strength(lbs)

XLPE

Poly

XLPE

Poly

6201 ALLOY NEUTRAL-MESSENGER

Minex

6

Solid

45

6

7

1,110

106.6

102.9

85

70

Hippa

6

7

45

6

7

1,110

113.2

105.7

85

70

Prawn

4

Solid

45

4

7

1,760

158.4

154.1

115

90

Barnacles

4

7

45

4

7

1,760

168.3

158.2

115

90

Shrimp

2

7

45

2

7

2,800

253.7

239.7

150

120

Gammarus

1/0

7

60

1/0

7

4,460

411.7

386.0

205

160

Leda

1/0

19

60

1/0

7

4,460

402.7

386.0

205

160

Dungenese

2/0

7

60

2/0

7

5,390

506.8

476.3

235

185

Cyclops

2/0

19

60

2/0

7

5,390

495.3

476.3

235

185

Dlustra

3/0

19

60

3/0

7

6,790

611.4

589.1

275

215

Lepas

4/0

19

60

4/0

7

8,560

757.1

730.5

315

245

Tags: , ,