VDE 0276 Standard 12/20 Kv 3X185mm2 N2xsy XLPE Insulation PVC Power Cable Mv Cable

VDE 0276 Standard 12/20 Kv 3X185mm2 N2xsy XLPE Insulation PVC Power Cable Mv Cable

Quick Details

VDE 0276 Standard 12/20 Kv 3X185mm2 N2xsy XLPE Insulation PVC Power Cable Mv Cable

Power Cable

Rneda

Yjv32

ISO, CCC, CE, RoHS, UL

Bare Copper Wire

Round Wire

PVC

XLPE

AC Cable

Low and Medium Voltage Cable

Underground

CE TUV BV Kema SABS Psb

1.5-800mm

Single 2 3 4 3+1 4+1 3+2

Copper or Aluminum

Underground

Steel Wire

Stranded or Solid

RNEDA

Wooden & Steel Drum

IEC DIN ASTM VDE BS

China

8544492100

Product Details

VDE 0276 Standard 12/20 Kv 3x185mm2 N2xsy XLPE insulation PVC power Cable MV Cable

TOP TEN CABLE MANUFACTURER IN CHINA

LARGEST CABLE MANUFACTUER IN NORTH CHINA

ANNUAL EXPORT VOLUME EXCEED 200MILLION USD

WITH UL,TUV,KEMA,CE,BV,PSB,SABS,LLOYD’S,GL,NK,KR,ABS PRODUCTS CERTIFICATIONS

WITH TUV TYPE TESTING REPORT

WIDE PRODUCTS RANGE

ISO9001,ISO18001,OHSAS18001 SYSTEM CERTIFICATIONS

CNAS APPROVAL LABROTARY

Product Description

1. Standard of XLPE Cable: According to GB12706( Equal to IEC60502)Also can do by standard of ASTM,BS,DIN and AS/NZS or other standards as request.

2. Rated Voltage of XLPE Cable:

0.6/1KV 6/10KV;8.7/15KV;12/20KV;18/20KV;21/35KV;6/35KV

3. Construction of XLPE Cable:

Conductor:Copper or Aluminum

Insulation:XLPE

Inner sheath:PVC or PE

Armoured:Galvanized steel tape,Galvanized steel wire

Outer Sheath:PVC or PE

NO. of cable cross: 1 core(Single core),2cores(Double cores),3cores, 4cores(4 equal-section-area cores OR 3 equal-section-area+1 small section area neutral core),5cores(5 3 equal-section-area cores+2 small area neutral cores OR 4 equal-section-area +1 small area neutral cores).We provide armored type and non-armored type for the cables stated above.

Also can do according to the customer’s request.

4. Characters of XLPE Cable:

a.Max  Long-time operating temperature of XLPE insulated cable is 90°C

b.Installing temperature of cable should not be less than 0°C

c.Max short-circuit temperature is not exceed 250°C,Not more than5 Sec.

d.Unable be laid without the limit of fall with enough mechanical pull,Single core cable can not be laid in iron tube or fixed by circled iron tools around cables

5. Description & Application of XLPE Cable:

TYPE

NAME

Main Application

CU core

AL core

 

 

YJV/YJY

YJLV/YJLY

XLPE insulated,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.Unable to bear external mechanical forces,but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated,steel tape armored,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.Able to bear external mechanical forces,but unable to bear large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated,thin steel wire armored,PVC/PE sheathed power cable

For laying in shaft,water underground will large difference of level.Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated,thick steel wire armored,PVC/PE sheathed power cable

For laying in water and seabed.Able to bear positive pressure and pulling force

6. Advantage:

a. Excellent electric and mechanical characteristics

b. Best Resistance chemical corrosion and heat-ageing,environment stress and flame-retardant

c. Simple in structure,Convenient to use

d. Reduce costs.

British Standard MV cables Voltage Rating

BS6622 – standard British MV cable 6.35/11kV 19/33kV  

BS7835 – LSZH British MV cable 6.35/11kV 19/33kV  

European standard MV cables Voltage Rating 

N2XSY – single copper core XLPE insulated with PVC oversheath 6/10kV 12/20kV 18/30kV

N2XS2Y – single copper core XLPE insulated with PE oversheath 6/10kV 12/20kV 18/30kV

NA2XSY – single aluminium core XLPE insulated with PVC oversheath 6/10kV 12/20kV 18/30kV

NA2XS2Y – single aluminium core XLPE insulated with PE oversheath 6/10kV 12/20kV 18/30kV

N2XSEY – 3 copper core XLPE insulated with PVC oversheath 6/10kV

N2XS(F)2Y – single copper core XLPE insulated with water blocking powder and PE oversheath 6/10kV 12/20kV 18/30kV

N2XS(FL)2Y – single copper core XLPE insulated with water blocking powder and aluminium tape tightly bonded to PE sheath 6/10kV 12/20kV  

NA2XS(F)2Y – single aluminium core XLPE insulated with water blocking powder and PE oversheath 6/10kV 12/20kV 18/30kV

NA2XS(FL)2Y – single aluminium core XLPE insulated with water blocking powder and aluminium tape tightly bonded to PE sheath 6/10kV 12/20kV 18/30kV
 

How contact us

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.