Underground Yjv XLPE Insulated Power Cable

Underground Yjv XLPE Insulated Power Cable

Underground Yjv XLPE Insulated Power Cable

YJV YJLV YJV22 YJLV22 YJV32 YJLV32

Construction, Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC Cable

XLPE

ISO, CCC, CE

1.5 – 1000mm2

1 – 5 Cores

Swa or Sta

1 – 35 Kv

20 Years

Jinshui

All Wooden Drum or Iron-Wooden Drum, All Iron Drum

China

8544492100

Product Description

———-Application:
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.

———-Construction:
Conductor: Copper (or Aluminium)
Insulation: XLPE
Filler: Non-hygroscopic Polypropylene(PP)
Binder Tape: Non-woven fabric
Inner Covering: PVC
Metallic Armour: Galvanized Steel Wire Armour(SWA)
Non-magnetic Steel Wire Armour(only for single core)
Aluminium Wire Armoured(AWA, only for single core)
Outer Sheath: PVC (or PE)

———-Standards:
The products are mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or alumimum conductor). Conductor long-time operating temperature is 90° C. In short circuit, conductor highest temperature should be not more than 250° C

———-Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.
2. No. Of core: Single-core, Three-core.
3. The highest allowed operating temperature of conductor for long-term working is 90° C. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250° C.
4. D. C Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0° C when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test: .
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.

————Technical Parameters of our Power Cable
1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890
2). Detailed description or construction:
* Conductor: compacted or uncompacted copper or aluminium
* Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
* Filler: Polypropylene filament with lapped binding tape
* Binder: Binding tape
* Inner sheath: Polyvinyl chloride (PVC)
* Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)
*Sheath: Polyvinyl chloride (PVC)
3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:
U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV
4). Voltage:
0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV
In the voltage designation of cables U0/U(Um):
* U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
* U is the rated power frequency voltage between conductors for which the cable is designed;
* Um is the maximum value of the "highest system voltage" for which the equipment maybe used.
5). Application:
For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.
6). Marking: According to the customers’ requirements
7). Nominal cross-sectional areas:
1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2

Type Designation Applications
VV
YJV
VLV
YJLV
Copper conductor, PVC ,XLPE insulated, PVC sheathed power cable
Aluminium conductor, PVC ,XLPE insulated, PVC sheathed power cable
For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single core cable is not permissible to lay in magnetic duct.
VY
YJY
VLY
YJLY
Copper conductor, PVC,XLPE insulated, PE sheathed power cable
Aluminium conductor, PVC ,XLPE insulated, PE sheathed power cable
VV22
YJV22
VLV22
YJLV22
Copper conductor, PVC ,XLPE insulated, steel tape armoured, PVC sheathed power cable
Aluminium conductor, PVC ,XLPE insulated, steel tape armoured, PVC sheathed power cable
For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force.
VV23
YJV23
VLV23
YJLV23
Copper conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable
Aluminium conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable
VV32
YJV32
VLV32
YJLV32
Copper conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable
Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable
For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force.
VV33
YJV33
VLV33
YJLV33
Copper conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable
Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable
Note: The armoured single core cables is only used for D.C. system. As for A.C. system, non-magnetic armour material should be applied.

Welcome your kind enquiry!