U-1000 Rgpfv 3X185mm2 Insulated and Sheathed Flame Retardant, XLPE/Gswa LSZH PVC

U-1000 Rgpfv 3X185mm2 Insulated and Sheathed Flame Retardant, XLPE/Gswa LSZH PVC

Quick Details

U-1000 Rgpfv 3X185mm2 Insulated and Sheathed Flame Retardant, XLPE/Gswa LSZH PVC

U1000RGPFV

Rne Da

Yjv32

ISO, CCC, CE, RoHS, VDE

Bare Copper Wire

Round Wire

PVC

XLPE

AC Cable

Low and Medium Voltage Cable

Construction, Underground, Industrial, Power Station

0.6/1kv

XLPE

PVC

Steel Wire Armour

1.5mm2-800mm2

1,2,3,4,5,3+1,3+2,4+1

ISO,Ce,CCC

RNE DA

Standard Export Drum

IEC60502

Hebei, China

8544492100

Product Details

                                            U 1000 ARGPFV RH C1 3×185

Description

Power and control cables armed with lead sheath 0.6/1kV, XP C 32-111, aliphatic and aromatic hydrocarbons resistant, are AD8 and AG4. These cables are fire retardant NF C 32070 C1.

STANDARDS

International :  IEC 60228; IEC 60332-3-24
National :  NF C 32-013; NF C 32-070/C1; NF C 32-070/C1; NF C 32-070/C2; NF C 32-090; XP C 32-111; XP C 32-111

DESCRIPTION

APPLICATIONS

These power and control cables are used for electricity supply in low voltage installation system. They are well adapted to underground use in industrial applications, in moist areas, where hydrocarbon and mechanical protections are needed. The lead sheath brings an enhanced resistance to aromatics hydrocarbons.

DESIGN

Conductor:
– Solid plain copper: 1.5 to 4 mm²
– Stranded plain copper or aluminium: 6 to 630 mm²
Insulation:
– Cross-linked polyethylene (XLPE)
Bedding (optional)
Inner sheath:
– Polyvinyl chloride (PVC) Colour: black
Lead cover
Armour
– Paraffin-waxed crepe paper
– Double steel tape (STA)
Outer sheath:
– Polyvinyl chloride (PVC). Colour: black.
 

CORE IDENTIFICATION

2 to 5 cores: according to HD 308 S2
> 5 cores: printed numbers
> 5G cores: printed numbers + green/yellow core

CONSTRUCTION CHARACTERISTICS
Conductor material Aluminum
Conductor flexibility Stranded class 2
With Green/Yellow core No
Lead Sheath Yes
DIMENSIONAL CHARACTERISTICS
Number of cores 3
Conductor cross-section 185mm²
Diameter over inner sheath 43.8mm
Diameter over lead sheath 47.8mm
Diameter over armour 52.7mm
Minimum outer diameter 51.1mm
Maximum outer diameter 65.0mm
Approximate weight 8099kg/km
ELECTRICAL CHARACTERISTICS
Rated Voltage Uo/U (Um) 0.6/1 kV
MECHANICAL CHARACTERISTICS
Mechanical resistance to impacts Good
USAGE CHARACTERISTICS
Fire retardant NFC 32070 C1, IEC 60332-3-24
Chemical resistance Aliphatic and aromatic hydrocarbons resistant
Max. conductor temperature in service 90°C
Operating temperature, range -20 .. 60°C

 

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.