TUV/CE Certified 11kv/22kv/33kv Mv Copper Conductor XLPE 185mm2 Cable
Quick Details
Product Details
and/or the BS, DIN and/or other types of international standards.
We can also produce flame retardant cable, water blocking cable,low-smoke
low-halogen cable and low-smoke halogen-free cable,and also can design and
produce cables according to the requirement of our clients.
Structure
Conductor: Solid or stranded copper/Aluminum
Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
Filler: Polypropylene filament with lapped binding tape
Binder: Binding tape
Inner sheath: Polyvinyl chloride (PVC)
Armoring: Single Core: AWA (Aluminium Wire Armour)
Multi-Core: SWA (Steel Wire Armour) STA (Steel Tape Armour)
Sheath: Polyvinyl chloride (PVC)
Application
1, Long term working temperature for the cable with PVC insulated is 70ºC;
Long term working temperature for the cable with XLPE insulated is 90ºC
2, Short circuit temperature
For PVC insulated cable, the highest conductor temperature is not more than160ºC. (lasting time, not over 5 seconds).
For XLPE insulated cable, the highest conductor temperature is not more than250ºC. (Lasting time is not over 5 seconds).
3, Laying temperature not less than 0ºC and the drop height is out of consideration.
4, The cable with chemical stability, anti-acid, anti-alkali, anti-oil, anti-organic solvent, not easy to be burning.
5, Easy for installation, easy bending and light.
Operating characteristics
– Rated power-frequency voltage U0/U: 3.6/6kv~26/35kv.
– Max.admissible operating temperature of the conductor:90ºC.
– Max. short-circuit temperature of conductor shall not exceed 2500C. (5s maximum duration)
– The ambient temperature under installation should not below 00C.
– The bending radius of a single-core cable should not less than 20 times the cable diameter.
The bending radius of a multi-core cable should not less than 15 times the cable diameter.
Table of the voltage, cores, and cross-section
Item | Category A, B | 3.6/6kV | 6/10kV | 8.7/15kV | 12/20kV | 18/30kV | 21/35kV |
Category A ,B | 6/6kV | 8.7/10kV | 12/15kV | 18/20kV | – | 26/35kV | |
Single-core | mm2 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 |
Three core | mm2 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 |
The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault lasting time altogether should not be over 125 hours, Category C includes all the system except Category A and B.
5 Type and Name
Type | Designation | Applications | |
YJV | Copper conductor, XLPE insulated, PVC sheathed power cable | For laying indoors, in a tunnel or cable trench, unable to bear external mechanical forces.The single-core cable is not allowed to lay in the magnetic duct. | |
YJLV | Aluminum conductor, XLPE insulated, PVC sheathed power cable | ||
YJY | Copper conductor, XLPE insulated, PE sheathed power cable | ||
YJLY | Aluminum conductor, XLPE insulated, PE sheathed power cable | ||
YJV22 | Copper conductor, XLPE insulated, steel tape armored, PVC sheathed power cable | For laying indoors, in a tunnel in cable trench, or direct in ground, able to bear external mechanical forces.The single-core cable is not allowed to lay in the magnetic duct. | |
YJLV22 | Aluminum conductor, XLPE insulated, steel tape armored, PVC sheathed power cable | ||
YJV23 | Copper conductor, XLPE insulated, steel tape armored, PE sheathed power cable | ||
YJLV23 | Aluminum conductor, XLPE insulated, steel tape armored, PE sheathed power cable | ||
YJV32 | Copper conductor, XLPE insulated, steel wire armored, PVC sheathed power cable | For laying indoors, in tunnel cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force. | |
YJLV32 | Aluminum conductor, XLPE insulated, steel wire armored, PVC sheathed power cable | ||
YJV33 | Copper conductor, XLPE insulated, steel wire armored, PE sheathed power cable | ||
YJLV33 | Aluminum conductor, XLPE insulated, steel wire armored, PE sheathed power cable |
- Next: Overhead Aluminum Cable for Mv Transmission Line
- Previous: UL Certificate PVC Insulated Thhn 12 AWG Wire 4 AWG Thhn Nylon Jacket
Contact us
Similar Or Related
-
TUV/CE Certified 11kv/22kv/33kv Medium Voltage Copper Conductor XLPE 185mm2 Cable
-
600 / 1000V Aluminum / Copper Conductor PVC Insulated PVC Sheathed Armoured Cable
-
50mm 70mm 4 Core Armoured XLPE Insulated Copper Aluminum Cable Price Per Meter
-
TUV/CE Certified 11kv/22kv/33kv Mv Copper Conductor XLPE 185mm2 Cable