Tree Wire, Aerial Cable, 5 Kv, AAC/HDPE (ANSI/ICEA S-66-524)

Tree Wire, Aerial Cable, 5 Kv, AAC/HDPE (ANSI/ICEA S-66-524)

Tree Wire, Aerial Cable, 5 Kv, AAC/HDPE (ANSI/ICEA S-66-524)

Tree Wire

Overhead

Low and Medium Voltage Cable

DC Cable

HDPE

Round Wire

Aluminum 1350

ISO, CCC

Tree Wire

Boan

5 Kv

4-500 AWG or Kcmil

1

7-37

DingAn

Heated Steel-Wooden Drum/Wooden Drum

SGS

Jiangsu Yixing, China

8544492100

Product Description

Tree Wire, Overhead Cable, 5 KV, AAC/HDPE (ANSI/ICEA S-66-524)
Construction
AAC (1350-H19), AAAC or ACSR conductors, concentrically stranded. Available with black or gray trackresistant, high-density polyethylene (HD) or black track-resistant crosslinked polyethylene (XLP) covering.

Application
Used for primary and secondary overhead distribution where limited space is available or desired for rights-of-way. Installed the same as bare conductors, however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. Tree Wire – Used for spans where trees crowd the right-of-way, such as in wooded residential areas, when a minimum of interference with the environment is desired. Covering minimizes power outages due to conductor contact with tree limbs, reducing the need for frequent or severe trimming. Covered Aerial MV Cable – Installed with other Covered Aerial MV cables and a supporting messenger through a series of spacemaintaining devices (spacers). The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation, particularly useful in congested areas.

Specifications
5kV Covered Aerial MV Cable – Tree Wire meets or exceeds all applicable ICEA specifications and the following ASTM specifications:
B-230 Aluminum, 1350-H19 Wire for Electrical Purposes.
B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors.
B-232 Concentric-Lay-Stranded, Aluminum Conductors, Coated Steel Reinforced (ACSR).
B-498 Zinc-Coated (Galvanized) Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
B-399 Standard Specification for Concentric-Lay-Stranded, Aluminum Alloy 6201-T81 Conductors.

Size Stranding Cover Thickness Cable O.D.+ Rated Strenght Weight per 1000ft. Allowable Ampacity*
(AWG or kcmil) (mils) (mils) (lbs) (lbs)
4 7 80 385 793 73 135
2 7 80 443 1210 104 180
1 19 80 482 1570 123 210
1/0 19 80 522 1940 148 240
2/0 19 80 565 2400 179 275
3/0 19 80 616 2980 218 320
4/0 19 80 672 3620 266 370
250 37 80 718 4420 304 410
266.8 19 80 734 4470 325 425
300 37 80 771 5300 356 455
336.4 37 80 807 5790 395 490
350 37 80 821 6080 409 505
477 37 80 931 7820 541 610
500 37 80 950 8200 565 625