Superalloy AAAC Cable/All Aluminum Alloy Conductor 25mm 35mm 40mm 50mm 150mm 170mm 300mm
Superalloy AAAC Cable/All Aluminum Alloy Conductor 25mm 35mm 40mm 50mm 150mm 170mm 300mm
JS-AAA012
Bare
Stranded
Overhead, Heating
Aluminum
Bare
ISO9001, CE, UL, CCC, RoHS, VDE
15.5, 24.7,39.2,62.4
Bare
Overhead AAAC Line Conductor IEC 61089 (All Alumin
Astmb399 Bs En50182
10 Years
Silver
JINSHUI CABLE
Drum
SGS, CCC
Henan
Product Description
superalloy AAAC cable/All Aluminum Alloy Conductor 25MM 35MM 40MM 50MM 150MM 170MM 300MM
DESCRIPTION
The conductor consists of Aluminum Magnesium-Silicon alloy wires stranded in successive layers in opposite direction and the outer layer is right hand direction Z. Natural grease may be applied between the layers of AAAC except the outer layer.
STANDARD
Construction as per ASTMB399,DIN48201,BS EN50182,IEC61089,CSA49
APPLICATION :
AAAC bare conductors are used for primay and secondary overhead power transmission lines haveing long spans and high resistance to corrosion .
Product photo :
CERTIFICATE:
Nominal Area (mm2) |
Cross Section (mm2) |
Stranding and wires Dia. (mm) |
Overall Dia. (mm) |
Weight (kg/km) |
Rated strength (kN) |
Max.D.C. Resistance (Ω/km,20ºC) |
BOX | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.55 | 1.7480 |
ACACIA | 23.8 | 7/2.08 | 6.24 | 64.9 | 7.02 | 1.3828 |
ALMOND | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.88 | 1.0926 |
CEDAR | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.46 | 0.9273 |
DEODAR | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.44 | 0.7797 |
FIR | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.11 | 0.6875 |
HAZEL | 59.9 | 7/3.30 | 9.90 | 163.4 | 17.66 | 0.5494 |
PINE | 71.6 | 7/3.61 | 10.8 | 195.6 | 21.14 | 0.4591 |
HOLLY | 84.1 | 7/3.91 | 11.7 | 229.5 | 24.79 | 0.3913 |
WILLOW | 89.7 | 7/4.04 | 12.1 | 245.0 | 26.47 | 0.3665 |
OAK | 118.9 | 7/4.65 | 14.0 | 324.5 | 35.07 | 0.2767 |
MULBERRY | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.52 | 0.2192 |
ASH | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.31 | 0.1830 |
ELM | 211.0 | 19/3.76 | 18.8 | 579.2 | 62.24 | 0.1568 |
POPLAR | 239.4 | 37/2.87 | 20.1 | 659.4 | 70.61 | 0.1387 |
SYCAMORE | 303.2 | 37/3.23 | 22.6 | 835.2 | 89.40 | 0.1095 |
UPAS | 362.1 | 37/3.53 | 24.7 | 997.5 | 106.82 | 0.0917 |
YEW | 479.0 | 37/4.06 | 28.4 | 1319.6 | 141.31 | 0.0693 |
TOTARA | 498.1 | 37/4.14 | 29.0 | 1372.1 | 146.93 | 0.0666 |
RUBUS | 586.9 | 61/3.50 | 31.5 | 1622.0 | 173.13 | 0.0567 |
SORBUS | 659.4 | 61/3.71 | 33.4 | 1822.5 | 194.53 | 0.0505 |
ARAUCARIA | 821.1 | 61/4.14 | 37.3 | 2269.4 | 242.24 | 0.0406 |
REDWOOD | 996.2 | 61/4.56 | 41.0 | 2753.2 | 293.88 | 0.0334 |
Code name |
Cross Section (mm2) |
Stranding and wires Dia. (in) |
Overall Dia. (mm) |
Weight (1b/1000ft) |
Rated strength (kN) |
Max.D.C. Resistance (Ω/km,20ºC) |
Akron | 15.5 | 7/0.0661 | 5.04 | 28.52 | 4.92 | 2.159 |
Alton | 24.7 | 7/0.0834 | 6.36 | 45.40 | 7.83 | 1.356 |
Ames | 39.2 | 7/0.1052 | 8.01 | 72.24 | 12.4 | 0.8547 |
Azusa | 62.4 | 7/0.1327 | 10.11 | 114.9 | 18.9 | 0.5365 |
Anaheim | 78.6 | 7/0.1490 | 11.34 | 144.9 | 23.8 | 0.4264 |
Amherst | 99.3 | 7/0.1672 | 12.75 | 182.5 | 30.0 | 0.3373 |
Alliance | 125 | 7/0.1878 | 14.31 | 230.2 | 37.8 | 0.2678 |
Butte | 159 | 19/0.1283 | 16.3 | 291.6 | 46.5 | 0.2112 |
Canton | 200 | 19/0.1441 | 18.3 | 367.9 | 58.6 | 0.1676 |
Cairo | 236 | 19/0.1565 | 19.9 | 433.9 | 69.2 | 0.1417 |
Darien | 284 | 19/0.1716 | 21.8 | 521.7 | 83.1 | 0.1181 |
Elgin | 331 | 19/0.1853 | 23.55 | 608.3 | 97.0 | 0.1012 |
Flint | 375 | 37/0.1415 | 25.13 | 690.8 | 107 | 0.08944 |
Greeley | 470 | 37/0.1583 | 28.14 | 864.6 | 135 | 0.07133 |
- Next: China High Quality Low Voltage Rubber Sheathed Flat Flexible Cable for Mining
- Previous: 3*25+1*16 Rubber Sheathed Flexible Mine Cable