Superalloy AAAC Cable/All Aluminum Alloy Conductor 25mm 35mm 40mm 50mm 150mm 170mm 300mm

Superalloy AAAC Cable/All Aluminum Alloy Conductor 25mm 35mm 40mm 50mm 150mm 170mm 300mm

Superalloy AAAC Cable/All Aluminum Alloy Conductor 25mm 35mm 40mm 50mm 150mm 170mm 300mm

JS-AAA012

Bare

Stranded

Overhead, Heating

Aluminum

Bare

ISO9001, CE, UL, CCC, RoHS, VDE

15.5, 24.7,39.2,62.4

Bare

Overhead AAAC Line Conductor IEC 61089 (All Alumin

Astmb399 Bs En50182

10 Years

Silver

JINSHUI CABLE

Drum

SGS, CCC

Henan

Product Description


superalloy AAAC cable/All Aluminum Alloy Conductor 25MM 35MM 40MM 50MM 150MM 170MM 300MM

DESCRIPTION

The conductor consists of Aluminum Magnesium-Silicon alloy wires stranded in successive layers in opposite direction and the outer layer is right hand direction Z. Natural grease may be applied between the layers of AAAC except the outer layer.

STANDARD

Construction as per ASTMB399,DIN48201,BS EN50182,IEC61089,CSA49

APPLICATION :

AAAC bare conductors are used for primay and secondary overhead power transmission lines haveing long spans and high resistance to corrosion .

Product photo :

CERTIFICATE:

Nominal
Area
 
(mm2)
Cross
Section
 
(mm2)
Stranding and wires Dia.
(mm)
Overall Dia.
 
(mm)
Weight
 
 
(kg/km)
Rated strength
 
(kN)
Max.D.C.
Resistance
 
(Ω/km,20ºC)
BOX 18.8 7/1.85 5.55 51.4 5.55 1.7480
ACACIA 23.8 7/2.08 6.24 64.9 7.02 1.3828
ALMOND 30.1 7/2.34 7.02 82.2 8.88 1.0926
CEDAR 35.5 7/2.54 7.62 96.8 10.46 0.9273
DEODAR 42.2 7/2.77 8.31 115.2 12.44 0.7797
FIR 47.8 7/2.95 8.85 130.6 14.11 0.6875
HAZEL 59.9 7/3.30 9.90 163.4 17.66 0.5494
PINE 71.6 7/3.61 10.8 195.6 21.14 0.4591
HOLLY 84.1 7/3.91 11.7 229.5 24.79 0.3913
WILLOW 89.7 7/4.04 12.1 245.0 26.47 0.3665
OAK 118.9 7/4.65 14.0 324.5 35.07 0.2767
MULBERRY 150.9 19/3.18 15.9 414.3 44.52 0.2192
ASH 180.7 19/3.48 17.4 496.1 53.31 0.1830
ELM 211.0 19/3.76 18.8 579.2 62.24 0.1568
POPLAR 239.4 37/2.87 20.1 659.4 70.61 0.1387
SYCAMORE 303.2 37/3.23 22.6 835.2 89.40 0.1095
UPAS 362.1 37/3.53 24.7 997.5 106.82 0.0917
YEW 479.0 37/4.06 28.4 1319.6 141.31 0.0693
TOTARA 498.1 37/4.14 29.0 1372.1 146.93 0.0666
RUBUS 586.9 61/3.50 31.5 1622.0 173.13 0.0567
SORBUS 659.4 61/3.71 33.4 1822.5 194.53 0.0505
ARAUCARIA 821.1 61/4.14 37.3 2269.4 242.24 0.0406
REDWOOD 996.2 61/4.56 41.0 2753.2 293.88 0.0334
Code 
name
Cross
Section
 
(mm2)
Stranding and wires Dia.
 
(in)
Overall Dia.
 
(mm)
Weight
 
 
(1b/1000ft)
Rated strength
 
(kN)
Max.D.C.
Resistance
 
(Ω/km,20ºC)
Akron 15.5 7/0.0661 5.04 28.52 4.92 2.159
Alton 24.7 7/0.0834 6.36 45.40 7.83 1.356
Ames 39.2 7/0.1052 8.01 72.24 12.4 0.8547
Azusa 62.4 7/0.1327 10.11 114.9 18.9 0.5365
Anaheim 78.6 7/0.1490 11.34 144.9 23.8 0.4264
Amherst 99.3 7/0.1672 12.75 182.5 30.0 0.3373
Alliance 125 7/0.1878 14.31 230.2 37.8 0.2678
Butte 159 19/0.1283 16.3 291.6 46.5 0.2112
Canton 200 19/0.1441 18.3 367.9 58.6 0.1676
Cairo 236 19/0.1565 19.9 433.9 69.2 0.1417
Darien 284 19/0.1716 21.8 521.7 83.1 0.1181
Elgin 331 19/0.1853 23.55 608.3 97.0 0.1012
Flint 375 37/0.1415 25.13 690.8 107 0.08944
Greeley 470 37/0.1583 28.14 864.6 135 0.07133

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.