Submarine Power Cable/XLPE

Submarine Power Cable/XLPE

Product Description

marine power cable/XLPE  

 

1. marine power cable/XLPE
2.power cable munufacturers,1500,000km/m
3.free cable sample
4.insulation:XLPE
5.ASTM,BS,NFC

 

1) Standard :IEC60502,GB/T 12706

 

2).Voltage :0.6/1KV

 

3).Specification:

 

Type

Designation

Application

VV

Copper conductor ,PVC insulated ,PVC sheathed power cable

For laying indoors, in tunnel or cable trench,unable to bear extermal mechanical forces. Single core cable is not permissible to lay in magnetic duct

VLV

Aluminium conductor ,PVC insulated ,PVC sheathed power cable

VY

Copper conductor, PVC insulated, PE sheathed power cable

VLY

Aluminium conductor ,PVC insulated ,PE sheathed power cable

VV22

Copper conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable

For laying indoors, in cable trench or direct in ground ,able to bear external mechanical forces, but unable to bear pulling force

VLV22

Aluminium conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable

VV23

Copper conductor ,PVC insualted ,steel tape armoured ,PE sheathed power cable

VLV23

Alunminium conductor ,PVC insulated ,steel tape armoured ,PE sheathed power cable

VV32

Copper conductor, PVC insulated, steel wire armoured,PVC insulated power cable

 

For laying indoors, in cable or direct in ground ,able to bear external mechanical forces, but unable to bear large pulling forces

VLV32

Aluminium conductor, PVC insulated ,steel tape armoured ,PVC sheathed power cable

VV33

Copper conductor, PVC insulated steel wire armoured , PE sheathed power cable

VLV33

Aluminium conductor , PVC insulated , streel wire armoured ,PE sheathed power cable

Note: The armoured single core cables is only used for D.C.system. As for A.C.system,non-magnetic armored material should be applied

 

4).nominal cross-sectional areas:1.5 mm, 2.5 mm,4 mm, 6 mm, 10 mm, 16 mm,25 mm, 35 mm, 50 mm,70 mm, 95 mm,120 mm,150 mm,185 mm,240 mm,300 mm2  400 mm2 500 mm2 630 mm2 800 mm2

 

5)production range: single core cable from 1.5 mmto 800 mm2,muli-core cable from 1.5 mm2  to 400 mm2

 

6).operating characteristics:

Rated power-frequency voltage u0/u:0.6/1 KV

Max permissible continuous operating temperature of conductor 70

Max short-circuit temperature of the conductor shall not exceed (Max 5 seconds duration): cross-section of conductor  300 mm2

 

The anbient temperature under installations should not be below 0

Tags: