Stay Wire (Guy wire) BS 183 16mm2

Stay Wire (Guy wire) BS 183 16mm2

Stay Wire (Guy wire) BS 183 16mm2

16mm2

Bare

Stranded

Overhead

Steel

None

None

Round Wire

ISO9001, CE, CCC, VDE

Jinshui

JINSHUI

Reel, Drum

CE, ASTM, BS, IEC

P. R. China

Product Description


Quick Details
Place of Origin: Henan, China (Mainland)
Brand Name: JINSHUI
Model Number: STAY WIRE
Insulation Material: NONE
Type: Galvanized
Application: Construction
Conductor Material: steel wire
Jacket: None
certificate: ISO 9001
Constroction: 1*3 1*7 1*19 and so on
Packaging & Delivery

Packaging Details: Drum Reel
Delivery Detail: 45 DAYS

Specifications
galvanized steel wire stand, stay wire, earth wire and hot-dipped steel wire strand ,overhead Ground or static wire

Aerial earth wire for BS 183, ASTM IEC 888 1 x 7, 1 x 19 and 1 x 37
As overhead ground (or static) wire for protection against lighting
1 x 7 construction strand with grade A galvanization and with group one tensile strength is mostly used for this application
Strand is installed at the top of steel tower and functions as a ground (earth) wire to protect the aluminum conductor with steel reinforced (ACSR) from lightening
With its normal lifespan of 20 to 30 years, thick galvanized layer better than or equivalent to that of galvanized strand for ACSR is recommended
For telecommunication cable (self-supporting type)
Used to support self-supporting (SS) telecommunication cable, which has replaced obsolete lead-plated cables
1 x 7 strands with group one tensile strength and grade A galvanization are widely used for this application
The telecom cable and galvanized strands are coated together with a poly-ethylene insulation
As messenger wire to support utility lines
Used at train railroad, streetcar line and subway railroad, either 1 x 7 or 1 x 19 construction strands are used
As guying wire (for poles and towers)
Used as guying wire for various poles, towers for power and telecom cables, the industry is moving towards using higher strength strands with better corrosion protection for this application
For ACSR (aluminum conductor steel reinforced)
Used to supports ACSR cable as the core strength member, for power cables with above 60kV capacity, ACSR is widely used in replacement of hard cu-strand conductors, in comparison with hard Cu cables, ACSR weighs 20% less with 1.7 times increase in strength so that the interval between power transmission towers can be doubled
All trademarks shown here are for reference purposes only. They are the property of their respective owners, and we are not authorized to sell items bearing such trademarks.

Ref. No. Description Unit Data
STAY WIRE mm2 16
1 Manufacturer HENAN JINSHUI CABLE GROUP CO.,LTD
2 Material STAY WIRE
3 Standards for design BS 183
Grade of steel 1300
4 Stranding of galvanised steel wire No/mm 7/1.8
5 Lay of outer steel wire mm
6 Design cross-sectional areas: (Total) mm² 16
7 Over all Diameter mm 5.4
8 Weight per km kg/km 140
9 Granted minimum breaking load kN 23.2
10 Maximum working tension (40% of breaking load) kN 9.28
11 Coefficient of liner expansion 1/ °C 11.5×10-6
12 Modulus of elasticity N/mm² 191000
13 Maximum length of stranded wire on reel m 500
14 Maximum mass of stranded wire plus reel kg 70
15 Minimum tensile breaking stress Kg/mm2 1320
16 Minimum stress at 1% elongation Kg/mm2 1140
17 Elongation of 200 mm length in breaking % 4%
18 Elastic limit of material as percentage of tensile strength % /

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.