SIP-2 SIP-4 Wire Aluminum Self-Supporting Aerial Bundled Conductor Service Cables

SIP-2 SIP-4 Wire Aluminum Self-Supporting Aerial Bundled Conductor Service Cables

SIP-2 SIP-4 Wire Aluminum Self-Supporting Aerial Bundled Conductor Service Cables

SIP-1 SIP-2 SIP-3 SIP-4

Insulated

Stranded

Overhead

Aluminum

Crosslinking

XLPE / PE

Round Wire

for Overhead Transmission Lines

ISO9001, CCC

SGS

Hongda

600/1000V, 20kv, 35kv

OEM, ODM

Hongda, or OEM

1000m Per Drum, 4000m Per Drum

2x16mm2, 4x16mm2, 2x25mm2, 4x25mm2

China

8544492100

Product Description

SIP-2 SIP-4 wire aluminum self-supporting Aerial Bundled Conductor Service cables

Self supporting insulated wires (Aerial Bundled Conductor) SIP per GOST R 52373-2005 and TU 16-705.500-2006
(TU 16-705.500-2006 used instead of TU 16.71-268-98 and TU 16.71- 272-98)

SIP-1 – self supporting wire with Al cores, with insulation from light-stabilized cross-linked PE, neutral messenger non-insulated core from Al alloy.
SIP-2 – self supporting wire with Al cores, with insulation from light-stabilized cross-linked PE, with zero residential (larger diameter), covered with insulation
SIP-3 – protected self supporting wire, with conducting core from Al alloy with insulation from lightstabilized cross-linked PE.
SIP-4 – protected self supporting wire, without currier element, with Al conducting cores with insulation from light-stabilized cross-linked PE.

CONSTRUCTION
1. CONDUCTING CORE – Al round core for all cross-section the core is compacted multiwire, the quantity of wire in phase core. Outer diameter of conducting core and its electrical resistance shown in bellow table:

Nominal cross-section of phase core
mm2
Number of wires in the core
units.
Outer diameter of conducting core
mm
Electrical resistance of 1 km of phase core to DC, ohm not more
Min. Max.
16 7 4,6 5,1 1,910
25 7 5,7 6,1 1200
35 7 6,7 7,1 0,868
50 7 7,85 8,35 0,641
70 7 9,45 9,95 0,443
95 7 11,1 11,7 0,320
120 19 11,1 13,1 0,253
150 19 14,0 14,5 0,206
185 19 15,45 16,15 0,164
240 19 17,75 18,45 0,125

2. NEUTRAL MESSENGING CORE – form Al alloy, round core, stranded from round wires,
compacted. Nominal cross-sections, number of wires in the core, outer diameter of core, its burst capacity and electrical resistance are specified in the bellow table:

Nominal cross-section of phase core
mm2
Number of wires in the core
units.
Outer diameter of conducting core
mm
Electrical resistance of 1 km of phase core to DC, ohm not more
Min. Max.
25 7 5,7 6,1 1,380
35 7 6,7 7,1 0,986
50 7 7,85 8,35 0,720
54,6 7 9,2 9,6 0,630
70 7 9,45 9,95 0,493
95 7 11,1 11,7 0,363
120 19 12,2 12,9 0,288
150 19 13,9 14,5 0,236
185 19 15,75 16,15 0,188
240 19 17,75 18,45 0,145

3. INSULATION – in SIP-1 the neutral core is not insulated. In other conductors the insulation made from light-stabilized cross-linked PE. Insulated phase cores have the distinctive coloring. Insulation thickness is shown in the following table:

Types of wire Nominal isulation thickness, mm
16 25 35 50 54,6 70 95 120 150 185 240
SIP-1 1,3 1,3 1,3 1,5 1,5 1,7 1,7 1,7 1,7 1,9 1,9
SIP-2
SIP-3 20 kV 2,3
SIP-3 35 kV 3,5
SIP-4 1,3 1,3

APPLICATION
SIP-1 – for overhead transmission lines (TL) and linear TL deviations in atmosphere types I and II as per GOST 15150-69
SIP-2 – for overhead transmission lines (TL) and linear TL deviations in atmosphere types I and II as per GOST 15150-69 , including sea coasts, salt lakes shores, in industrial areas
SIP-3 – for TL with nominal voltage 10-35 kV in atmosphere types II and III as per GOST 15150-69 , including sea coasts, salt lakes shores, in industrial areas
SIP-4 – for TL deviations to entry and for laying in walls of buildings and engineering structures in
atmosphere types II and III as per GOST 15150-69

Mark and rated voltage wire Number and nominal cross-phase and zero bearing veins sht.h
mm2
Estimate the outer diameter of wire
mm
Estimated weight of 1 km of wire
kg/km
SIP-1 0,6 / 1 kV 116+125 15 135
316+125 22 270
325+135 26 390
335+150 30 530
350+150 32 685
350+170 35 740
370+170 37 930
370+195 41 990
395+170 41 1190
395+195 43 1255
3120+195 46 1480
3150+195 48 1715
3185+195 52 2330
3240+195 56 2895
SIP-2 0,6 / 1 kV 316+125 24 308
316+154,6* 28 427
325+135 27 424
325+154,6* 30 512
335+150 31 571
335+154,6* 32 606
350+150 34 727
350+154,5* 35 762
350+170 36 798
370+154,6* 39 973
370+170 40 1010
370+195 41 1087
395+170 43 1240
395+195 45 1319
3120+195 48 1553
3150195 50 1787
3185+195 55 2403
3240+195 60 2968
SIP-3 20 kV 135 12 165
150 13 215
170 15 282
195 16 364
1120 18 445
1150 19 540
1185 24 722
1240 24 950
SIP-3 20 kV 135 14 209
150 16 263
170 17 334
195 19 421
1120 20 518
1150 22 618
1185 24 808
1240 26 1045
SIP-4 0,6/1 kV 216 15 139
416 18 278
225 17 196
425 21 392