Single Core Overhead XLPE Insulated Aluminium Covered Line Wire and Cable

Single Core Overhead XLPE Insulated Aluminium Covered Line Wire and Cable

Single Core Overhead XLPE Insulated Aluminium Covered Line Wire and Cable

35mm2, 50mm2, 75mm2

Insulated

Stranded

Overhead

Steel-Al

Crosslinking

Fiberglass

Inner Screen

Round Wire

Overhead

ISO9001, RoHS

Jytop

 IEC502/IEC227 

1kv~10kv

JYTOP

Packed in Coils or Reels

95mm2, 120mm2, 150mm2

Zhengzhou, China

8544601200

Product Description

Single Core Overhead XLPE Insulated Aluminium Covered line wire and Cable

1. Introduction
It consists of copper or aluminum conductor, inner shielding layer, weather-prrof insulation material and outer shielding layer. It has not only power-transmitting character of power cable, but strong mechanical character of aerial cable as well. In comparison with bare wire, it boasts many advantages such as small span in laying the cable, high reliability and good aging-resistant character.

2.Executive Standard
GB12527-90 1KV Overhead Insulated Cable( According to IEC502/IEC227 Standard)
GB14049-93 10KV Overhead Insulated Cable

3. Working conditions of Overhead Insulated Cable
(1) Rated voltage: 1KV, 10KV
(2) The highest work temperature of the cable conductor:XLPE Insulated cable 90ºC,HDPE Insulated
cable 75ºC.

(3) During having a short(lasting less than 5 seconds), the maximum temperature: XLPE insulated cable 250ºC,HDPE insulated cable 150ºC.
(4) During the cable lying temperature must be above -20ºC.
(5) Bending radius allowance of the cable:
A:1KV overhead insulated cable: It should be no less than 4D for the cable with outer diameter less
than 25mm; It should be no less than 6D for the cable with outer diameter of 25mm or more.
B: 10KV overhead insulated cable:
Single core cable: 20 (D+d)±5%mm; Multl-core cable: 15 (D+d)±5%mm.
Formula inside: D—Actual cable outer diameter; d—Actual conductor outer diameter.

4. Conductor DC resistance, Insulate resistance & conductor splitting force

NCS-Area m Conductor DC resistanace MΩ.km Insulate resistance MΩ.km Conductor Min Splitting Source
1KV 10KV
Hard Cu Soft Cu AL 70ºC 90ºC 20ºC Hard Cu Al
10 1.906 1.83 3.08 0.0067 0.67

Common 1500

3471 1650
16 1.198 1.15 1.91 0.0065 0.65 5486 2517
25 0.749 0.727 1.2 0.0054 0.54 8465 3762
35 0.540 0.524 0.868 0.054 0.54 11731 5177
50 0.399 0.387 0.641 0.0046 0.46 16502 7011
70 0.276 0.268 0.443 0.004 0.40 23461 10354
95 0.199 0.193 0.320 0.0039 0.39

Light 1000

31579 13727
120 0.158 0.153 0.253 0.0035 0.35 39911 17339
150 0.128 / 0.206 0.0035 0.35 49505 21033
185 0.1021 / 0.164 0.0035 0.35 61846 26732
240 0.0777 / 0.125 0.0034 0.34 79823 34679
300 0.0619 / 0.100 / / 99788 43349

5. Diameter and weight of 1KV overhead AL-Ste 1-core cable

AL Nominal Area m Steel Nominal Area m Reference diameter mm Approximate weight kg/km
JKLGYJ JKLGY
25 4 9.2 134 134
35 6 10.8 180 180
50 8 12 241 241
70 10 13.8 318 318
95 15 16.2 442 443
120 20 17.8 556 557
150 25 19.8 695 696
185 30 22.4 892 894
240 30 25 1147 1149
300 40 28.6 1424 1426

6. Diameter and weight of 10KV AL-Ste 1-core common type insulate overhead cable

AL Nominal Area m Steel Nominal Area m Reference diameter mm Approximate weight kg/km
JKLGYJ JKLGY
35 6 15.8 265 267
50 8 17.0 335 336
70 10 18.8 421 423
95 15 21.0 550 552
120 20 22.6 672 674
150 25 24.2 808 810
185 30 26.4 1003 1005
240 30 28.6 1251 1254
300 40 31.8 1524 1527

7. Diameter and weight of 10KV AL-Ste 1-core light type insulate overhead cable

AL Nominal Area m Steel Nominal Area m Reference diameter mm Approximate weight kg/km
JKLGYJ JKLGY
25 4 12 171 172
35 6 13 218 219
50 8 14.2 283 284
70 10 16 366 367
95 15 18 487 489
120 20 19.6 606 607
150 25 21.2 737 739
185 30 23.4 926 928
240 30 25.6 1169 1171
300 40 28.8 1433 1435

KINDLY NOTE: If you want to know more details about this kind of products, please visit our website:jytopcable for further information. Thanks.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.