Service Drop ABC Cable Quadruplex 3*1/0AWG+1/0AWG Standardbred

Product Description
Brief description of ABC Cable:
Aerial Bundled Cable(ABC) has an aluminium conductor with a PVC OR XLPE sheath. ABC usually has 3 cores plus neutral, the neutral can either be bare or insulated and the cable can have a street light of 25mm². ABC is available in 600/1000v, 635/11kV or 12,7/22kV. We stock 1 core, 2 core and 3 core ABC cable.
XLPE(PE) insulated ABC cable (service drop)
1.Applications
Primarily used for overhead service applications such as street lighting. Outdoor lighting, and temporary service for construction. To be used at voltages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75°c for polyethylene insulated conductors or 90°c for crossliked polyethylene(XLPE) insulated conductors.
2.Construction
Concentric strand or compressed 1350-H19 conductor, poly- ethylene or cross linked polyethylene insulation,concentric strand AAC, ACSR or 6201 alloy neutral messenger.
3.Types:
XLPE(PE) insulatedabc cable (service drop)covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor , etc. And we can still produce the cables according to the request of customers.
4.Detaild Introduction of XLPE(PE) insulatedabc cable (service drop)
4.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
4.2 Triplex Service Drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
overhead transformer
4.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
overhead transformer
5.Standards
5.1 B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
5.2 B-231 Aluminum Conductors, Concentric-Lay-Stranded.
5.3 B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
5.4 B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5.5 B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
5.6 Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
overhead transformer
- Next: Electric Cable Manufacturer in China Henan Jinshui Cable ABC Overhead Cable
- Previous: 0.6/1kv Low Voltage Twisted Aluminum Cable 3X35 Sq. mm Triplex
Contact us
You May Like
Product List
- All Aluminum Alloy Conductor AAAC Cable Bare Aluminium Conductor
- Aluminum Conductor ACSR for Overhead Power Transmission Line
- ASTM B232 Standard Aluminum Conductor Steel Reinforced Bare Conductor ACSR
- Aluminum Conductor Steel Reinforced AAC AAAC ACSR Overhead Conductor
- Aluminum-Clad Steel Wire (ACS wire) and Aluminum Clad Steel Stranded (ACS cable)
- BS183 Stay Wire Gsw 7/3.25mm Hot Dipped Galvanized Steel Wire Guy Wire Price
- Aluminum Conductor Steel Supported Acss Bare Conductor
- Electric Transmission Line Aluminum Clad Steel Wire Acs Cable
- Acss Aluminum Conductor Steel Supported Acss/Aw Conductors
- Copper Clad Wire CCA Wire Stranded
- XLPE Insulated Aluminium Conductor Service Drop Aerial Bundle ABC Cable
- Overhead XLPE Insulated Aluminum Cable ABC Bundled Cable
- Overhead Aluminum Conductor XLPE Insualted Aerial Bundled ABC Cable
- Aerial Bundled ABC AWG 1/0 2/0 3/0 4/0 Aluminum Twisted Cable
- 0.6/1kv 3X120+1X25+1X70mm2 Aerial Bundled Conductors Aluminium ABC Cable
- 33kv Overhead ABC Bundled Cable with AAC ACSR Neutral Aluminum Conductor
- Overhead XLPE Insualted Aluminum Conductor Aerial Twisted Bundled ABC Cable
- Low Voltage Covered Line Aluminum Wire Cable for Overhead Distribution
- 600 Volt Secondary Ud Quadruplex Aluminum Conductor with XLPE Insulation
- Overhead Power Transmission Lines Conductors ABC Triplex Bundled Cables
- Nyy, Nyy-J, Nyy-O Copper PVC Insulation Flame Retardant PVC Sheath Power Cable
- 3X95mm2 Aluminium XLPE Insulated Armoured Yjv Electrical Power Cable
- 120mm 4core Aluminium XLPE Insulated Awa Armoured Power Cable
- XLPE Insulated Steel Tape Armoured Power Cable
- Medium Voltage Mv Tr-XLPE Insualted Urd Cable Copper Steel Wire Armoured
- Aluminium Conductor XLPE Insulated Awa Aluminum Steel Wire Armoured Cable
- 3 Core Copper Conductor XLPE Insulated PVC Sheath Jacks Electric Wire
- Aluminum XLPE Insulated PVC Insualted Sheated Power Cable
- 0.6/1kv Aluminum or Copper XLPE Insulation PVC Sheath Power Cable
- N2xsey 3*240mm2 Copper XLPE Insulation PVC Sheath Copper Wire Screen Power Cable
- Single Core Copper Flexible PVC Insulated Electric Wire Cable
- Ce Certificate Copper PVC Jacketed Electric Building Wire and Cable
- H07V-R Flexible PVC Insulated Electric Cable and Wire
- PVC Insulated Copper Wire (BVR) Building Wire
- H07V-K, H07V-U, H07V-R 450/750V Copper PVC Insulating Sheath Wire and Cable
- H03VV-F, H05VV-F 3*1.5mm Copper Flexible PVC Insulated Electric Power Cable
- UL1185 Standard Copper or Aluminum Conductor XLPE Insulation Hook up Electronic Wire
- H05VV-F 3G1.5mm2 Power Cords Cable Copper Core PVC Insulated Electric Wire VDE Standard
- Electric Wire Cable with Copper PVC Wire 2.5mm
- PVC Jacket Flexible Battery Cable, Electrical Wire Cable