Quadruplex Cable 3+1 Aluminum Conductor XLPE Insulated

Quadruplex Cable 3+1 Aluminum Conductor XLPE Insulated

Quadruplex Cable 3+1 Aluminum Conductor XLPE Insulated

jkyjv

Insulated

Stranded

Overhead

Aluminum

XLPE

ISO9001

Quuadruplex(3+1) Aluminum Conductor Cable

Yifang

Drum, Reel or According to Customers' Request

IEC, BS, DIN, ASTM, GOST, JIS etc

China

8544492100

Product Description

Quadruplex Service Drop Aluminum Conductors AAC Neutral-Messenger
Quadruplex Service Drop Aluminum Conductors ACSR Neutral-Messenger
Quadruplex Service Drop Aluminum Conductors AAAC 6201 Alloy Neutral-Messenger

Applications
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75 for polyethylene insulated conductors or 90 for cross linked polyethylene (XLP) insulated conductors.

Construction
Conductors are concentrically stranded, compressed 1350- H19 aluminum. Insulated with either polyethylene or XLP cross linked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.

Standards
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum conductors, Concentric-Lay-Stranded.
B-232 Aluminum Conductors, Concentric-Lay-Stranded,Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

Note
Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB-399 for 6201.Conductor temperature of 90C for XLR 75C for Poly; ambient temperatures of 40; emissivity 0.9; 2ft./sec/wind in sun. To determine currentampacity by conductor size, please consult The National Electric Code, latest edition.

Item # Phase conductor size AWG Phase conductor stranding Phase conductor Insulation Thickness Bare Neutral Messenger Size AWG Bare Neutral Messenger Stranding Bare Neutral Messenger breaking strength Weight Per 1000ft-XLP Weight Per 1000ft-Poly Ampacity -XLP Ampacity -Poly
Clydesdale 4 7/w 45 mls 4 7 881 Lbs 208 Lbs 201.8 Lbs 100 Amps 80 Amps
Pinto 4 7/w 45 mls 4 7 881 Lbs 223 Lbs 207.9 Lbs 100 Amps 80 Amps
Mustang 2 19/w 45 mls 2 7 1350 Lbs 333 Lbs 312.6 Lbs 135 Amps 105 Amps
Criollo 1/0 19/w 60 mls 1/0 7 1990 Lbs 529 Lbs 504.5 Lbs 180 Amps 140 Amps
Percheron 2/0 19/w 60 mls 2/0 7 2510 Lbs 649 Lbs 620.5 Lbs 205 Amps 160 Amps
Hanoverian 3/0 19/w 60 mls 3/0 19 3310 Lbs 799 Lbs 765.6 Lbs 235 Amps 185 Amps
Oldenburg 4/0 19/w 60 mls 4/0 19 4020 Lbs 986 Lbs 946.7 Lbs 275 Amps 210 Amps
Morochuca 6 7/w 45 mls 6 6/1 1190 Lbs 152 Lbs 147.4 Lbs 75 Amps 60 Amps
Chola 6 Solid 45 mls 6 6/1 1190 Lbs 162 Lbs 151.7 Lbs 75 Amps 60 Amps
Morgan 4 7/w 45 mls 4 6/1 1860 Lbs 226 Lbs 220 Lbs 100 Amps 80 Amps
Hackney 4 7/w 45 mls 4 6/1 1860 Lbs 241 Lbs 226.1 Lbs 100 Amps 80 Amps
Palomino 2 19/w 45 mls 2 6/1 2850 Lbs 362 Lbs 342.6 Lbs 135 Amps 105 Amps
Costena 1/0 19/w 60 mls 1/0 6/1 4380 Lbs 575 Lbs 550.6 Lbs 180 Amps 140 Amps
Grullo 2/0 19/w 60 mls 2/0 6/1 5310 Lbs 707 Lbs 678.7 Lbs 205 Amps 160 Amps
Suffolk 3/0 19/w 60 mls 3/0 6/1 6620 Lbs 872 Lbs 838.9 Lbs 235 Amps 185 Amps
Appaloosa 4/0 19/w 60 mls 4/0 6/1 8350 Lbs 1079 Lbs 1039.2 Lbs 275 Amps 210 Amps
Bronco 336.4 19/w 80 mls 336.4 6/1 8580 Lbs 1613 Lbs 1568.2 Lbs 370 Amps 280 Amps
Gelding 336.4 19/w 80 mls 4/0 6/1 8350 Lbs 1548 Lbs 1494.3 Lbs 370 Amps 280 Amps
Bay 6 Solid 45 mls 6 7 1110 Lbs 145 Lbs 140.0 Lbs 75 Amps 60 Amps
French Coach 6 7/w 45 mls 6 7 1110 Lbs 155 Lbs 144.3 Lbs 75 Amps 60 Amps
German Coach 4 Solid 45 mls 4 7 1760 Lbs 214 Lbs 208.3 Lbs 100 Amps 80 Amps
Arabian 4 7/w 45 mls 4 7 1760 Lbs 229 Lbs 214.4 Lbs 100 Amps 80 Amps
Belgian 2 7/w 45 mls 2 7 2800 Lbs 344 Lbs 323.1 Lbs 135 Amps 105 Amps
Shetland 1/0 19/w 60 mls 1/0 7 4460 Lbs 546 Lbs 521.1 Lbs 180 Amps 140 Amps
Thoroughbred 2/0 19/w 60 mls 2/0 7 5390 Lbs 670 Lbs 641.5 Lbs 205 Amps 160 Amps
Trotter 3/0 19/w 60 mls 3/0 7 6790 Lbs 825 Lbs 791.8 Lbs 235 Amps 185 Amps
Walking 4/0 19/w 60 mls 4/0 7 8560 Lbs 1019 Lbs 979.7 Lbs 275 Amps 210 Amps

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.