PVC/Swa/PVC 0.6/1 Kv Armoured Cables up to 240 mm2

PVC/Swa/PVC 0.6/1 Kv Armoured Cables up to 240 mm2

PVC/Swa/PVC 0.6/1 Kv Armoured Cables up to 240 mm2

ARMOURED CABLES

Construction, Underground, Power Station

Low and Medium Voltage Cable

DC & AC

PVC

PVC

Round Wire

Aluminum or Copper

ISO, CCC

Armoured Cables

Yifang

Yifang cable

Wooden Drum

1.5 mm2 UP to 240 mm2

China

8544492100

Product Description

PVC/SWA/PVC 0.6/1 KV ARMOURED CABLES  1.5 mm2 UP to 240 mm2

The type , name and suitable place of the cables

type name Suitable for
Copper-conductor AL-conductor
VV VLV PVC insulated and sheathed power cable Installation in such place as indoor, tunnel, pipeline, cable channel, and flammable and deep-corrosion areas; the mechanical force is unavailable.
VY VLY PVC-insulated cable sheathed with polythene Installation in such place as indoor, tunnel, pipeline, cable channel, and flammable and deep-corrosion areas; the mechanical force is unavailable.
VV22 VLV22 PVC insulated and  sheathed cable with copper tape Installation in such place as indoor, cable channel, underground and deep-corrosion areas; the lager tension is unavailable.
VV23 VLV23 PVC insulated and  sheathed cable with steel tape Installation in such place as indoor, cable channel, underground and deep-corrosion areas; the lager tension is unavailable.
VV32 VLV32 PVC insulated and  sheathed cable armored with thin steel wire Installation in such place as underground, vertical shaft, water and deep-corrosion areas; the lager tension is unavailable.
VV33 VLV33 PVC–insulted and polythenesheathed cables armored with thin steel wire Installation in such place as underground, vertical shaft, water and deep-corrosion areas; the lager tension is unavailable.
VV42 VLV42 PVC insulated and  sheathed cable armored with thick steel wire Installation in such place as underground, vertical shaft, water and deep-corrosion areas; the lager tension is unavailable.
VV43 VLV43 PVC–insulted and polythenesheathed cables armored with thick steel wire Installation in such place as underground, vertical shaft, water and deep-corrosion areas; the lager tension is unavailable.

production range

Rated voltageUo/Ukv
Cross-section areamm2
Core number
0.6/1 1.8/3 3.6/6
1  single 1.5-1000 10-1000 10-800
2  double 1.5-240 10-240 10-300
3 triple 1.5-300 10-300 10-300
3+1
3 thick ones+1 thin one
2.5-300 10-300
4
 
2.5-300 10-300
5
 
2.5-300 10-300
3+2
3 thick ones + 2 thin ones
2.5-300 10-300
4+1
4thick ones +1thin one
2.5-300 10-300  

Tags: , ,