PVC Insulated Steel Tape Armoured Power Cable (3-120+1-70)

PVC Insulated Steel Tape Armoured Power Cable (3-120+1-70)

PVC Insulated Steel Tape Armoured Power Cable (3-120+1-70)

3-120+1-70

Underground

Low and Medium Voltage Cable

AC Cable

XLPE

PVC

Round Wire

Bare Copper Wire

ISO, CCC, CE

Jinshui

JINSHUI

Drum, Reel

CE, SGS, CCC, ISO

Zhengzhou Henan

Product Description


1). Standard: IEC60502; GB12706.1-2002

2) Specification: Circular Copper conductor for single core and shaped conductors for muti-core, XLPE insulated, PVC bedding, armored(or unarmored) PVC sheathed cable.
Detailed description or construction:
* Conductor: compacted or uncompacted copper or aluminium
* Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
* Filler: Polypropylene filament with lapped binding tape
* Binder: Binding tape
* Inner sheath: Polyvinyl chloride (PVC)
* Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)
*Sheath: Polyvinyl chloride (PVC)
3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:
U0/U(Um) =3.6/6(7.2)-6/10(12)-8.7/15(17.5)-12/20(24)-18/30(36)-21/35(40.5)KV
In the voltage designation of cables U0/U(Um):
* U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
* U is the rated power frequency voltage between conductors for which the cable is designed;
* Um is the maximum value of the "highest system voltage" for which the equipment maybe used
4) Voltage:0.6/1kv,6/6kv,6/10kv,8.7/15kv,12/20kv,18/30kv,19/33kv,26/35kv

5). Application:used in ducts, trays and direct burial in ground. the cable is subjuct to immerse in water all the time.

6).This series includes:Single copper(Alumunium) core XLPE insulated PVC sheated
* Single copper(Alumunium) core XLPE insulated steel tape armoured PVC sheathed
* Single copper(Alumunium) core XLPE insulated steel wire armoured PVC sheateed
* Multi-core copper(Alumunium) core XLPE insulated PVC PVC sheath
* Multi-core copper(Alumunium) core XLPE insulated PVC inner sheath steel tape armoured PVC sheath
* Multi-core copper(Alumunium) core XLPE insulated PVC inner sheath steel tape armoured PVC sheath
7).Product feature
a.Max Long-time operating temperature of XLPE insulated cable is 90(70)°C.
b.Installing temperature of cable should not be less than 0°C.
c.Max short-circuit temperature is not exceed 250(160)°C, not more than 5 sec.

8). Marking: According to the customers’ requirements

9).Nominal cross-sectional areas:
1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2
10).types

Model Name Main Application
V V PVC Insulated Sheathed Power Cable For laying in doors, pipe and kin tunels, but unable to bear pulling force.
VLV
V V22 PVC Insulated steel tape armoured and PVC sheathed power cable For laying on in indoor, tunels and underground, able to bear pulling force and pressure
VLV22
V V32 PVC insulated fine steel wire armoured and PVC sheathed power cable For laying indoor, tunels and water, bear certain axis pulling force
VLV32
ZR-V V PVC insulated PVC sheathed flame retardant power cable For laying indoor, pipe and kin tunels, but unable to bear pulling force and pressure.
ZR-VLV
ZR-V V22 PVC insulated steel tape armoured and PVC sheathed flame retardant power cable For laying indoor, tunnels and underground, able to bear pulling force and pressure
ZR- VLV22
ZR-V V32 PVC insulated fine steel wire armoured and PVC sheathed flame retardant power cable For laying indoor, tunnels and water, able to bear pulling force and pressure.
ZR-VLV 32
ZR-V V42 PVC insulated steel wire armoured and PVC sheathed flame retardant power cable For laying tunels, water and other upright place, bear certain axis pulling force
ZR-VLV42

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.