PVC Insulated and Sheathed Light Fine Wired Cable H03VV-F

PVC Insulated and Sheathed Light Fine Wired Cable H03VV-F

PVC Insulated and Sheathed Light Fine Wired Cable H03VV-F

H03VV-F RVV

Hebei Huatong Cables

ISO9001, CE, UL, CCC, RoHS, VDE

Lighting, Household Appliance

Round Wire

PVC

PVC

Copper

Household Use

Stranded

Insulated

Hebei Huatong

Roll

50m/roll, 100m/roll, 500m/drum

China

8544492100

Product Description

Application

 

Flexible cable for dry areas, used for purposes requiring special flexibility in conditions free of any mechanical stresses. Permitted frequent bending and twisting. Specially suitable for application in small devices with low mechanical loads and for connection of light household devices such as kitchen appliances, desk lamps, ceiling lamps, vacuum cleaners, office machines, radios etc., as long as the cable is adapted to essential specifications of the device.

Construction

Conductor:    bare copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295                        (nominal diameter 0,20 mm)

Insulation:     PVC compound TI2 acc. to DIN VDE 0207 4. part / HD 21.1 S4, concentrically stranded cores                               color marked acc. to  HRN HD 308 S2 / DIN VDE 0293-308, with or without yellow-green                                       protective conductor

Sheath:           PVC compound TM2 for flexible insulated conductors acc. to DIN VDE 0207 part 5 / HD 21.1 S4

sheath colour:   white or black

• Core identification:

2 core – blue, brown

3 core – green/yellow, blue, brown

4 core – green/yellow, red, blue, brown.

5 Cores: green/yellow, brown, Black, red, blue

Technical data:
Temperature range:
                        during installation:              +5 °C up to +70 °C
                              fixed installed:                     -30 °C up to +70 °C
                               at short circuit of max. 5 s:   up to 150 °C
                              ambient temperature at storage:  up to 40 °C
  Nominal voltage:                  Uο/U = 300/500 V
  Test voltage :                         2000 V
  Minimal inner bending radius: 4D for D < 8 mm
                                                       5D for 8 – 12mm
                                                       6D for D > 12 mm
    Behaviour in fire:                     IEC 60332-1