PVC Insulated and Sheath Sta Armor Flexible Copper Control Cable

Product Description
Used as power and connecting cables in mechanical engineering for tooling machinery, control unit, production lines, transportation equipment, conveyor and assembly lines as well as in plant construction under the circumstance that the rated voltage is up to 450/750V AC.
2. Standard
National Standard GB/T9330-2008, produced according to IEC\DIN\BS
3. Rated Voltage: 450/750V
4. Construction:
1, copper conductor
2, PVC/PE/XLPE insulated
3, PVC sheathed
4. Copper wire braid/Aluminum-plastic shield/copper tape wrapped/unarmored
Steel tape armored
5. Type (see following table)
| Type | Name | Section Area (mm2) | No.of Core | Application Site |
| KVV | CopperConductor,PVC Insulated and Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
| 4 6 | 2-14 | |||
| 10 | 2-10 | |||
| KVVP | Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded Control Cable |
0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors, in cable ditches or pipes where shielding is required |
| 4 6 | 2-14 | |||
| 10 | 2-10 | |||
| KVVP2 | Copper Conductor, PVC Insulated and Sheathed,Copper-tape Screened Control Cable |
0.75 1.0 1.5 2.5 | 4-10 | Permanent installation indoors, in cable ditches or pipes where shielding is required |
| 4 6 | 7-61 | |||
| 10 | 4-10 | |||
| KVV22 | Copper Conductor, PVC Insulated and Sheathed,Steel tape Armored Control Cable |
0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches, Be able to withstand stronger external mechanical force |
| 4 6 | 4-14 | |||
| 10 | 4-14 | |||
| KVVR | Copper Conductor, PVC Insulated and Sheathed,Flexible Control Cable |
0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
| KVVRP | Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable |
0.5 0.75 1.0 | 4-61 | Installation indoors where flexibility shielding and movability are required |
| 1.5 2.5 | 4-48 | |||
| KYJV | CopperConductor, XLPE Insulated and PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
| 4 6 | 2-14 | |||
| 10 | 2-10 | |||
| KYJVP | Copper Conductor, XLPE Insulated,Braiding Shielded, PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
| 4 6 | 2-14 | |||
| 10 | 2-10 | |||
| KYJV22 | CopperConductor,XLPE Insulated,Steel-tape Armoured, PVCSheathed Control Cable |
0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches, pipes or underground Be cable to with stand stronger external mechanical force |
| 4 6 | 4-14 | |||
| 10 | 4-10 | |||
| KYJVP2 | CopperConductor,XLPE Insulated,Copper tape Screened, PVCSheathed Control Cable |
0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors, in cable ditches or pipes where shielding is required |
| 4 6 | 4-14 | |||
| 10 | 4-10 | |||
| KYJVR | CopperConductor,XLPE Insulated, PVCSheathed Flexible Control Cable |
0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
| KYJVRP | CopperConductor,XLPE Insulated,Braiding Shielded, PVC Sheathed Flexible Control Cable |
0.5 0.75 1.0 | 4-61 | |
| 1.5 2.5 | 4-48 | Installation indoors where flexibility shielding and movability are required |
- Next: PVC Insulation Nylon Jacket Thhn Wire Building Wire
- Previous: Thw Thhn Building Wire 450/750V Electric Wire
Contact us
Similar Or Related
-
15kV 3 Core 4/0AWG Aluminum Conductor XLPE Insulated SWA Armored MV Power Cable
-
15kV 1 Core 500 MCM Aluminimum Conductor XLPE Insulated Power Cable AWA Armored Wire Armoured
-
70mm2 6.35/11kV 3 Core XLPE Insulated Cu SWA Armored Electric Cable IEC 60502-2
-
Electric XLPE Power Cable 11kV PILC Cu 3 Core 120mm2 Armoured IEC 60502-2