Professional Manufacturer Supply ACSR Bare Conductor
Product Description
(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
Standards | IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110 |
Certificate | ISO 9001 and ISO 14001. CE ,SONCAP |
Type | AAC, AAAC, ACSR, AACSR&ACAR conductor |
AAC | AAC(All aluminum conductor) are suited for overhead power line. We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. |
AAAC | (AAAC) Conductor as per ASTM-B-399-1992 |
ACSR | ACSR bare conductor meets or exceeds the following ASTM specifications: B-230 Aluminum Wire, 1350-H19 for Electrical Purposes B-231 Aluminum Conductors, Concentric-Lay-Stranded B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW) B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) |
Code word | Size of Conductor |
Stranding and Wire Diameter | Overall Diameter | Max.D.C. Resistance at 20°C | Code word | Size of Conductor | Stranding and Wire Diameter | Overall Diameter | Max.D.C. Resistance at 20°C |
AWG or MCM | mm | mm | ohm/km | AWG or MCM | mm | mm | ohm/km | ||
Peachbell | 6 | 7/1.554 | 4.67 | 2.1692 | Verbena | 700 | 37/3.493 | 24.45 | 0.0813 |
Rose | 4 | 7/1.961 | 5.89 | 1.3624 | Nasturtium | 715.5 | 61/2.75 | 24.76 | 0.0795 |
Lris | 2 | 7/2.474 | 7.42 | 0.8577 | Violet | 715.5 | 37/3.533 | 24.74 | 0.0795 |
Pansey | 1 | 7/2.776 | 8.33 | 0.6801 | Cattail | 750 | 61/2.817 | 25.35 | 0.0759 |
Poppy | 1/0 | 7/3.119 | 9.36 | 0.5390 | Petunia | 750 | 37/3.617 | 25.32 | 0.0759 |
Aster | 2/0 | 7/3.503 | 10.51 | 0.4276 | Lilac | 795 | 61/2.90 | 26.11 | 0.0715 |
Phlox | 3/0 | 7/3.932 | 11.80 | 0.3390 | Arbutus | 795 | 37/3.724 | 26.06 | 0.0715 |
Oxlip | 4/0 | 7/4.417 | 13.26 | 0.2688 | Snapdragon | 900 | 61/3.086 | 27.78 | 0.0632 |
Valerian | 250 | 19/2.913 | 14.57 | 0.2275 | Cockscomb | 900 | 37/3.962 | 27.73 | 0.0632 |
Sneezewort | 250 | 7/4.80 | 14.4 | 0.2275 | Goldenrod | 954 | 61/3.177 | 28.6 | 0.0596 |
Laurel | 266.8 | 19/3.01 | 15.05 | 0.2133 | Magnolia | 954 | 37/4.079 | 28.55 | 0.0596 |
Daisy | 266.8 | 7/4.96 | 14.9 | 0.2133 | Camellia | 1000 | 61/3.251 | 29.36 | 0.0569 |
Peony | 300 | 19/3.193 | 15.97 | 0.1896 | Hawkweed | 1000 | 37/4.176 | 29.23 | 0.0569 |
Tulip | 336.4 | 19/3.381 | 16.91 | 0.1691 | Larkspur | 1033.5 | 61/3.307 | 29.76 | 0.0550 |
Daffodil | 350 | 19/3.447 | 17.24 | 0.1625 | Bluebell | 1033.5 | 37/4.244 | 29.72 | 0.0550 |
Canna | 397.5 | 19/3.673 | 18.36 | 0.1431 | Marigold | 1113 | 61/3.432 | 30.89 | 0.0511 |
Goldentuft | 450 | 19/3.909 | 19.55 | 0.1264 | Hawthorn | 1192.5 | 61/3.551 | 31.05 | 0.0477 |
Syringa | 477 | 37/2.882 | 20.19 | 0.1193 | Narcissus | 1272 | 61/3.668 | 33.02 | 0.0477 |
Cosmos | 477 | 19/4.023 | 20.12 | 0.1193 | Columbine | 1351.5 | 61/3.78 | 34.01 | 0.0421 |
Hyacinth | 500 | 37/2.951 | 20.65 | 0.1138 | Carnation | 1431 | 61/3.89 | 35.03 | 0.0398 |
Zinnia | 500 | 19/4.12 | 20.6 | 0.1138 | Gladiolus | 1510.5 | 61/4.00 | 35.09 | 0.0376 |
Dahlia | 556.5 | 19/4.346 | 21.73 | 0.1022 | Coreopsis | 1590 | 61/4.099 | 36.51 | 0.03568 |
Mistletoe | 556.5 | 37/3.114 | 21.79 | 0.1022 | Jessamine | 1750 | 61/4.302 | 38.72 | 0.0325 |
Meadowsweet | 600 | 37/3.233 | 22.63 | 0.0948 | Cowslip | 2000 | 91/3.76 | 41.40 | 0.02866 |
Orchid | 636 | 37/3.33 | 23.31 | 0.0894 | Lupine | 2500 | 91/4.21 | 46.30 | 0.0230 |
Heuchera | 650 | 37/3.366 | 23.56 | 0.0875 | Trillium | 3000 | 127/3.90 | 50.75 | 0.0192 |
Flag | 700 | 61/2.72 | 24.48 | 0.0813 | Bluebonnet | 3500 | 127/4.21 | 54.80 | 0.01653 |
Factory View:
Q&C and testing equipment:
Loading and packing details:
Customer visit:
What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
- Next: Control Flexible Cables
- Previous: All Aluminum Alloy Conductor (AAAC)