Price of Electric Aluminum Alloy AAAC Conductor

Price of Electric Aluminum Alloy AAAC Conductor

Price of Electric Aluminum Alloy AAAC Conductor

AAAC

Bare

Stranded

Overhead

Aluminium Alloy

Bare

Bare

Round Wire

Overhead

ISO9001, CE, CCC

BV

Rmjt

High Voltage

All Aluminum Alloy Conductor

Power Transmission

6AWG, 4AWG, 2AWG, 1/0AWG…1750AWG

Yes

ASTM B399, BS En 50183, DIN 48201, IEC 61089

RMJT

Wooden Drum

250MCM, 400MCM, 450MCM, 550MCM, 750MCM, 800MCM.

China

7614900000

Product Description
Price of Electric Aluminum Alloy AAAC Conductor

1.Application
The AAAC is used for overhead power transmission lines , especially the electric power augmentation of old transmission lines. We specialized in the research and application of AAAC for almost ten years. When replacing the aluminium conductor steel reinforced , the AAAC can save 5-8% of the construction cost. This AAAC covers aluminium alloy (hard solution, heat-treated, cold worked, and artifically aged) round wires for electrical purposes to be used as component wires of aluminium alloy conductor and aluminium alloy conductor steel reinforced.

2.Standard:
ASTM B399,BS EN50183 ,BS 3242,DIN 48201,IEC 61089 etc.

3.Specification
All Aluminum Alloy Conductors ASTM B 399

All Aluminium Alloy Conductors(AAAC) ASTM B 399
AREA Stranding Wire Dia. Approx.
overall
diameter
Weight Nominal
Breaking
Load
Nom. DC
resistance
at 20 Deg.
Nominal Actual
AWGorMCM (mm2) (mm) (mm) (kg/km) (kN) (ohm/km)
6 13.3 7 1.554 4.67 37 4.22 2.5199
4 21.15 7 1.961 5.89 58 6.71 1.5824
2 33.63 7 2.474 7.42 93 10.68 0.9942
1/0 53.48 7 3.119 9.36 148 16.97 0.6256
2/0 67.42 7 3.503 10.51 186 20.52 0.4959
3/0 85.03 7 3.932 11.8 234 25.86 0.3936
4/0 107.23 7 4.417 13.26 296 32.63 0.3119
250 126.66 19 2.913 14.57 349 38.93 0.2642
300 152.1 19 3.193 15.97 419 46.77 0.2199
350 177.35 19 3.447 17.24 489 52.25 0.1887
400 202.71 19 3.686 18.43 559 59.74 0.1650
450 228 19 3.909 19.55 629 67.19 0.1467
500 253.35 19 4.12 20.6 698 74.64 0.1321
550 278.6 37 3.096 21.67 768 83.80 0.1202
600 303.8 37 3.233 22.63 838 91.38 0.1102
650 329.25 37 3.366 23.56 908 97.94 0.1016
700 354.55 37 3.493 24.45 978 102.20 0.0944
750 380.2 37 3.617 25.32 1049 109.60 0.0880
800 405.15 37 3.734 26.14 1117 116.80 0.0826
900 456.16 37 3.962 27.73 1258 131.50 0.0733
1000 506.71 37 4.176 29.23 1399 146.10 0.0660
AAAC (Characteristics of A2 Conductors) IEC 61089
Code
number
Area Number
of wires
Diameter Linear
mass
Rated
strength
D.C resistance
Wire Cond
mm2 mm mm kg/km kN Ohm/km
16 18.4 7 1.83 5.49 50.4 5.43 1.7896
25 28.8 7 2.29 6.86 78.7 8.49 1.1453
40 46 7 2.89 8.68 125.9 13.58 0.7158
63 72.5 7 3.63 10.9 198.3 21.39 0.4545
100 115 19 2.7 13.9 316.3 33.95 0.2877
125 144 19 3.1 15.5 395.4 42.44 0.2302
160 184 19 3.51 17.6 506.1 54.32 0.1798
200 230 19 3.93 19.6 632.7 67.91 0.1439
250 288 19 4.39 22 790.8 84.88 0.1151
315 363 37 3.53 24.7 998.9 106.95 0.0916
400 460 37 3.98 27.9 1268.4 135.81 0.0721
450 518 37 4.22 29.6 1426.9 152.79 0.0641
500 575 37 4.45 31.2 1585.5 169.76 0.0577
560 645 61 3.67 33 1778.4 190.14 0.0516
630 725 61 3.89 35 2000.7 213.9 0.0458
710 817 61 4.13 37.2 2254.8 241.07 0.0407
800 921 61 4.38 39.5 2540.6 271.62 0.0361
900 1036 91 3.81 41.8 2861.1 305.68 0.0321
1000 1151 91 4.01 44.1 3179 339.53 0.0289
1120 1289 91 4.25 46.7 3560.5 380.27 0.0258
1250 1439 91 4.49 49.4 3973.7 424.41 0.0231
All Aluminium Alloy Conductors (AAAC) BS EN 50183
Designation Area Stranding
wire Dia.
Overall
Diameter
Nominal
Breaking
Load
Nominal
DC Resistance
at 20
ºC
Standard Weight
mm2 No Φ mm kN Ohm/km kg/km
ASTER 22 22 7 2 6 7.15 1.4989 60
ASTER 34.4 34.4 7 2.5 7.5 11.17 0.9593 93.8
ASTER 54.6 54.6 7 3.15 9.45 17.73 0.6042 148.9
ASTER 75.5 75.5 19 2.25 11.3 24.55 0.4388 207.4
ASTER 117 117 19 2.8 14 38.02 0.2833 321.2
ASTER 148 148.1 19 3.15 15.8 48.12 0.2239 406.5
ASTER 181.6 181.6 37 2.5 17.5 59.03 0.1831 500.3
ASTER 228 227.8 37 2.8 19.6 74.04 0.146 627.6
ASTER 288 288.3 37 3.15 22.1 93.71 0.1154 794.3
ASTER 366 366.2 37 3.55 24.9 115.36 0.0908 1008.9
ASTER 570 570.2 61 3.45 31.1 185.33 0.0585 1576
ASTER 851 850.7 91 3.45 38 276.47 0.0394 2360.7
ASTER 1144 1143.5 91 4 44 360.22 0.0293 3173.4
ASTER 1600 1595.9 127 4 52 502.72 0.021 4427.5
Aluminium Alloy Conductors (AAAC) DIN 48201
Code
Number
Area. No.of
wires
Diameter Linear
Mass
Rated
Tensile
strengrh
DC Resistance
at 20ºC
Wire Cond.
mm 2 mm 2 mm mm kg/km daN Ω/km
16 15.89 7 1.7 5.1 43.3 444 2.091
25 24.25 7 2.1 6.3 66.2 677 1.3703
35 34.36 7 2.5 7.5 93.8 960 0.9669
50 49.48 7 3 9 135.1 1382 0.6714
50 48.35 19 1.8 9 132.7 1350 0.6905
70 65.81 19 2.1 10.5 180.7 1838 0.5073
95 93.27 19 2.5 12.5 256 2605 0.3579
120 116.99 19 2.8 14 322 3268 0.2854
150 147.11 37 2.25 15.8 406 4109 0.2274
185 181.62 37 2.5 17.5 500.3 5073 0.1842
240 242.54 61 2.25 20.3 670.3 6774 0.1383
300 299.43 61 2.5 22.5 827 8363 0.112
400 400.14 61 2.89 26 1104 11176 0.0838
500 499.63 61 3.23 29.1 1379 13960 0.06709
625 626.2 91 2.96 32.6 1732 17490 0.054
800 802.09 91 3.35 36.9 2218 22402 0.0418
1000 999.71 91 3.74 41.1 2767 27922 0.0335
AAAC 6201- All Aluminium Alloy Conductor AS 1531
Code
Name
Strands/Wire
Diameter
Overall
Diameter
(Approx)
Calculated
Equivalent
Aluminium Area
Sectional
Area
Approx.
Mass
Calculated
Minimum
Breaking Load
D.C.Resistence
at 20
ºC
mm mm mm2 mm2 kg/km kN Ω/km
Agate 7/1.75 5.25 14.3 16.84 46 4.71 1.972
Amethyst 7/2.25 6.75 23.7 27.83 76 7.78 1.194
Diamond 7/2.50 7.50 29.3 34.36 94 9.64 0.967
Dolomite 7/2.75 8.25 35.4 41.58 114 11.6 0.799
Emerald 7/3.00 9.00 42.2 49.48 136 13.9 0.671
Garnet 7/3.75 11.3 65.8 77.28 211 21.7 0.43
Jade 7/4.50 13.5 94.8 111.3 304 31.2 0.298
Jasper 7/4.75 14.3 106 124.0 340 34.8 0.268
Opal 19/3.25 16.3 134 157.6 433 44.2 0.212
Patronite 19/3.50 17.5 155 182.80 502 51.3 0.183
Pearl 19/3.75 18.8 178 209.8 577 58.8 0.159
Ruby 37/3.00 21.0 221 261.60 720 73.5 0.128
Ruthenium 37/3.25 22.8 260 307.00 845 86.1 0.109
Rutile 19/4.75 23.8 285 336.7 925 94.4 0.09991
Sapphire 37/3.75 26.3 345 408.50 1125 115 0.0819
Spinel 61/3.25 29.3 427 506.10 1396 135 0.0662
Tantalum 61/3.50 31.5 495 586.90 1620 156 0.0572
Topaz 61/3.75 33.8 568 673.40 1858 179 0.0498
Zircon 91/4.50 49.5 1220 1447 3997 384 0.0232
6201 All Aluminum Alloy Conductor ASTM B399
Code
Name
Area Size&Stranding
of ACSR with
equal diameter
No. and
diameter
Overall
diameter
Weight Nominal
breaking load
Nominal Actual
MCM mm2 AWG or MCM mm mm kg/km kN
AKRON 30.58 15.48 6 7/1.68 5.04 42.7 4.92
ALTON 48.69 24.71 4 7/2.12 6.35 68 7.84
AMES 77.47 39.22 2 7/2.67 8.02 108 12.45
AZUSA 123.3 62.38 1/0 7/3.37 10.11 172 18.97
ANAHEIM 155.4 78.65 2/0 7/3.78 11.35 217 23.93
AMHERST 195.7 99.22 3/0 7/4.25 12.75 273 30.18
ALLIANCE 246.9 125.1 4/0 7/4.77 14.31 345 38.05
BUTTE 312.8 158.6 266.8 19/3.26 16.3 437 48.76
CANTON 394.5 199.9 336.4 19/3.66 18.3 551 58.91
CAIRO 465.4 235.8 397.5 19/3.98 19.88 650 69.48
DARIEN 559.5 283.5 477 19/4.36 21.79 781 83.52
ELGIN 652.4 330.6 556.5 19/4.71 23.54 911 97.42
FLINT 740.8 375.3 636 37/3.59 25.16 1035 108.21
GREELEY 927.2 469.8 795 37/4.02 28.14 1295 135.47

4.Packing
Packing in wooden drums,steel wooden drums or as customer’s requirement.

5.Certificate
As first rank of the cable supplier in China, we have obtained CE, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.

6.Contacts
Vivian Wong| Project Manager | People’s Cable Group
Office Add:Room 1203 Building 4 East International Plaza No.85
Jinshui Road Zhengdong New Area Zhengzhou City Henan Province
Factory Add:No.13 Yongding Road Gongyi, Zhengzhou,China

T: 86-371-55367868 | M: 86-18339931106

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.