Power Distribution Service Cable Aerial Bundled Cable ABC Duplex Service Cable
Power Distribution Service Cable Aerial Bundled Cable ABC Duplex Service Cable
ABC Cable
Jinyuan
ABC
ISO, CCC, CE
Aluminum
Round Wire
None
XLPE/PE
AC Cable
Low and Medium Voltage Cable
Overhead
ABC Duplex Service Cable
ABC Service Cable
Manufacturer
400
100000m2
HUATONG
Drum/Container
ASTM BS EN
China
7614900000
Product Description
Power distribution service Cable Aerial bundled cable ABC service cable
APPLICATIONS
Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
SPECIFICATIONS
Jinyuan’s duplex service drop cable meets or exceeds the following ASTM specifications:
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
Jinyuan’s duplex service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
CONSTRUCTION
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or crosslinked polyethylene (XLP). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.
APPLICATIONS
Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
SPECIFICATIONS
Jinyuan’s duplex service drop cable meets or exceeds the following ASTM specifications:
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
Jinyuan’s duplex service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
CONSTRUCTION
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or crosslinked polyethylene (XLP). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.
Duplex Service Drop | |||||||||||
Code Word | Phase Conductor | Bare Neutral Messenger | Weight per 1000 ft. (lbs.) |
Allowable Ampacities+ |
|||||||
Size (AWG) |
Strand- ing |
Insul. Thick. (mils) |
Equiv. Dia. (AWG)++ |
Size (kcmil) |
Strand-ing | Rated Strength (lbs.) |
XLP | POLY | XLP | POLY | |
6201 ALLOY NEUTRAL-MESSENGER | |||||||||||
Chihuahua | 6 | 1 | 45 | 6 | 30.58 | 7 | 1110 | 65 | 65 | 85 | 70 |
Vizsla | 6 | 7 | 45 | 6 | 30.58 | 7 | 1110 | 68 | 68 | 85 | 70 |
Harrier | 4 | 1 | 45 | 4 | 48.69 | 7 | 1760 | 99 | 99 | 115 | 90 |
Whippet | 4 | 7 | 45 | 4 | 48.69 | 7 | 1760 | 103 | 103 | 115 | 90 |
Schnauzer | 2 | 7 | 45 | 2 | 77.47 | 7 | 2800 | 157 | 157 | 150 | 120 |
Heeler | 1/0 | 9 | 60 | 1/0 | 123.3 | 7 | 4460 | 250 | 250 | 205 | 160 |
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP). | |||||||||||
+ Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun. | |||||||||||
Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201. |
Code* Word | Phase Conductor | Bare Neutral Messenger | Weight per 1000 ft. (lbs.) |
Allowable Ampacities+ |
||||||
Size (AWG) |
Strand- ing |
Insul. Thick. (mils) |
Size (AWG) |
Strand-ing | Rated Strength (lbs.) |
XLP | POLY | XLP | POLY | |
AAC NEUTRAL-MESSENGER | ||||||||||
Pekingese | 6 | 1 | 45 | 6 | 7 | 563 | 61 | 61 | 85 | 70 |
Collie | 6 | 7 | 45 | 6 | 7 | 563 | 64 | 64 | 85 | 70 |
Dachshund | 4 | 1 | 45 | 4 | 7 | 881 | 92 | 92 | 115 | 90 |
Spaniel | 4 | 7 | 45 | 4 | 7 | 881 | 96 | 96 | 115 | 90 |
Doberman | 2 | 7 | 45 | 2 | 7 | 1350 | 147 | 147 | 150 | 120 |
Malemute | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 234 | 234 | 205 | 160 |
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP). | ||||||||||
+ Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun. |
Code* Word | Phase Conductor | Bare Neutral Messenger | Weight per 1000 ft. (lbs.) |
Allowable Ampacities+ |
||||||
Size (AWG) |
Strand- ing |
Insul. Thick. (mils) |
Size (AWG) |
Strand-ing | Rated Strength (lbs.) |
XLP | POLY | XLP | POLY | |
ACSR NEUTRAL-MESSENGER | ||||||||||
Setter | 6 | 1 | 45 | 6 | 6/1 | 1190 | 72 | 72 | 85 | 70 |
Shepherd | 6 | 7 | 45 | 6 | 6/1 | 1190 | 75 | 75 | 85 | 70 |
Eskimo | 4 | 1 | 45 | 4 | 6/1 | 1860 | 110 | 110 | 115 | 90 |
Terrier | 4 | 7 | 45 | 4 | 6/1 | 1860 | 115 | 115 | 115 | 90 |
Chow | 2 | 7 | 45 | 2 | 6/1 | 2850 | 176 | 176 | 150 | 120 |
Bull | 1/0 | 9 | 60 | 1/0 | 6/1 | 4380 | 280 | 280 | 205 | 160 |
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP). | ||||||||||
+ Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun. |